Manufacturer: JA Solar Registry: CEC Verified Engineering Specification

JA Solar JAM72S01-340/PR is a 340.0 W STC (313.9 W PTC) Mono-c-Si solar module ranking #13,575 of 21,677 CEC listings (below all-CEC median; higher than 36.1% of peers). It delivers 18.05% efficiency, 46.86 V Voc at 25 C, and 51.5 V cold Voc at -10 C (11 panels max per 600 V string).

STC Wattage
340.0 W
PTC Wattage
313.9 W
Voc @ 25C
46.86 V
Efficiency
18.05%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does JA Solar JAM72S01-340/PR Compare Against Peer CEC Listings?

CEC rank, roof space requirements, and NEC 690.7/690.8 limits for JA Solar JAM72S01-340/PR (Mono-c-Si) residential solar systems.

JA Solar JAM72S01-340/PR delivers 180.5 W/m2 (1.86 percentage points below 19.91% CEC median) and strong 92.3% PTC-to-STC heat retention (#13,268 of 21,677), placing it as a compact residential or specialty off-grid module useful on tight dormer roofs or battery cabins, though 8 kW requires 24 panels (487 sq ft). At -4 F (-20 C), string voltage climbs to 52.83 V per unit, capping 600 V circuits at 11 panels. Compare specs directly with Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M-340W (340.0 W).

Where Does JA Solar JAM72S01-340/PR Fall Across Listed CEC Models?

Comparison of JA Solar JAM72S01-340/PR (340.0 W STC) against all 21,677 California Energy Commission certified photovoltaic modules.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where JA Solar JAM72S01-340/PR (340.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCJA Solar JAM72S01-: 340.0 W

What Dataset Percentiles Define JA Solar JAM72S01-340/PR?

Relative ranking of JA Solar JAM72S01-340/PR across nameplate watts, 92.3% PTC thermal ratio, and module aperture efficiency.

JA Solar JAM72S01-340/PR Engineering BenchmarksPercentile comparison of JA Solar JAM72S01-340/PR wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage340.0 WPTC/STC Retention92.3%Module Efficiency18.05%

What Do the Dataset Ranks Show for JA Solar JAM72S01-340/PR?

Summary of JA Solar JAM72S01-340/PR output rank, 8 kW array size (24 panels), efficiency rating, and 600 V string limit.

Rank #13,575 / 21,677

340.0 W STC · Higher Than 36.1%

340.0 W STC (-45.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #15,007

18.05% Aperture Efficiency

Power density 180.5 W/m2 (1.86 percentage points below 19.91% CEC median). PTC/STC ratio: 92.3% (rank #13,268).

NEC 690.7 Limit

11 Panels Max @ -10 C (600 V)

Cold Voc reaches 51.5 V at -10 C (566.5 V string) and 52.83 V at -20 C (11 max).

8 kW Reference Array

24 Panels = 8,160 W STC

Occupies 45.2 m2 (487 sq ft) producing 7,534 W PTC; NEC 690.8 OCPD floor is 14.76 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 46.86 * (1 + (-0.283/100) * (-10 - 25)) = 51.5 V | OCPD = 1.56 * 9.46 = 14.76 A

Inputs from CEC Modules.csv for JA Solar JAM72S01-340/PR: Voc=46.86 V, beta_Voc=-0.283%/C, Isc=9.46 A, STC=340.0 W, Area=1.884 m2.

Result: 11 panels max on 600 V (566.5 V); 24 panels for 8 kW (487 sq ft).

What Are the Published CEC Specifications for JA Solar JAM72S01-340/PR?

Complete CEC test sheet for JA Solar JAM72S01-340/PR including Isc (9.46 A), Voc (46.86 V), and thermal temperature coefficients.

Official California Energy Commission (NREL SAM) test parameters for JA Solar JAM72S01-340/PR.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 340.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 313.9 W (92.3% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 46.86 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 9.46 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 38.18 V / 8.91 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.283 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 18.05% (1.884 m2) Array roof footprint density
Cell Count & Technology 72 cells (Mono-c-Si) Monofacial backsheet

How Many JA Solar JAM72S01-340/PR Panels Build a 6 kW, 8 kW, or 10 kW Array?

Residential array count and annual electric bill savings at 18.54 c/kWh US avg vs. California tariffs using JA Solar JAM72S01-340/PR.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 18 6.12 kW 365 sq ft $1,532 $2,590
8 kW Class 24 8.16 kW 487 sq ft $2,042 $3,454
10 kW Class 30 10.2 kW 608 sq ft $2,553 $4,317

Which Sibling Wattage & Trim Variants Belong to This JA Solar Series?

Related JA Solar power steps and black/silver trims consolidated into this JA Solar JAM72S01-340/PR series guide.

Sibling CEC listings grouped into the JA Solar JAM72S01-340/PR wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
JA Solar JAM72S01-335/PR 335.0 W 309.1 W 46.68 V 37.96 V 17.78%
JA Solar JAM72S01-340/PR 340.0 W 313.9 W 46.86 V 38.18 V 18.05%
JA Solar JAM72S01-345/PR 345.0 W 318.6 W 47.05 V 38.39 V 18.31%

How Many JA Solar JAM72S01-340/PR Modules Fit in a Cold-Weather String?

Verify freezing-morning voltage rise for JA Solar JAM72S01-340/PR (46.86 V STC) before wiring 600 V or 1,000 V strings.

Computed from Voc=46.86V and beta_Voc=-0.283%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 52.83 V 11 panels 581.1 V 18 panels
-10 C (14 F) 51.5 V 11 panels 566.5 V 19 panels
0 C (32 F) 50.18 V 11 panels 552.0 V 19 panels
25 C (77 F STC) 46.86 V 12 panels 562.3 V 21 panels

Which Cross-Brand Solar Modules Compare Closest to JA Solar JAM72S01-340/PR?

Four comparable CEC modules such as Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M-340W (340.0 W) for side-by-side solar quote checks.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M-340W
Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd
340.0 W Tie (0 W) 46.91 V 17.68% 91.4%
Anhui Rinengzhongtian Semiconductor Development Co Ltd QJM340-72
Anhui Rinengzhongtian Semiconductor Development Co Ltd
340.0 W Tie (0 W) 46.97 V 17.52% 91.0%
GCL System Integration Technology Co Ltd GCL-M6/72340
GCL System Integration Technology Co Ltd
340.0 W Tie (0 W) 46.6 V 17.53% 90.5%
GCL System Integration Technology Co Ltd GCL-M6/72H340
GCL System Integration Technology Co Ltd
340.0 W Tie (0 W) 46.6 V 17.53% 91.4%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for JA Solar JAM72S01-340/PR?

Evaluate JA Solar JAM72S01-340/PR (340.0 W STC, 46.86 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), JA Solar JAM72S01-340/PR reaches 52.83 V per panel—exceeding 11 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 24 panels for an 8 kW build require 487 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 24 panels (487 sq ft).
  • 2026 tax credit baseline: cash residential installs of JA Solar JAM72S01-340/PR carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

JA Solar JAM72S01-340/PR 8 kW Residential Fit

Needs 24 modules (487 sq ft) with a 15 A string OCPD, offsetting ~$2,042/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 11 panels (-10 C) or 11 panels (-20 C), or compare Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M-340W.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 313.9 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for JA Solar JAM72S01-340/PR by JA Solar grounded in CEC test data and NEC 690.7/690.8 limits.

How many JA Solar JAM72S01-340/PR panels fit on a 600 V winter solar string?

At -10 C (14 F), JA Solar JAM72S01-340/PR cold Voc rises from 46.86 V to 51.5 V (beta_Voc -0.283%/C), capping a 600 V string at 11 panels (566.5 V).

How much roof area does an 8 kW array of JA Solar JAM72S01-340/PR need?

An 8 kW DC system uses 24 JA Solar JAM72S01-340/PR modules (8,160 W STC / 7,534 W PTC), covering roughly 487 sq ft and saving ~$2,042/yr at 18.54 c/kWh.

How does JA Solar JAM72S01-340/PR compare against Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M-340W?

JA Solar JAM72S01-340/PR outputs 340.0 W STC (46.86 V Voc, rank #13,575 of 21,677), while Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M-340W delivers 340.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.