JA Solar JAM72D40-590/MB-US — CEC Solar Module Specifications

Manufacturer: JA Solar Registry: CEC Verified Engineering Specification

JA Solar JAM72D40-590/MB-US is a 590.0 W STC (561.0 W PTC) Mono-c-Si solar module ranking #1,597 of 21,677 CEC listings (top 8.1%; higher than 91.9% of peers). It delivers 23.41% efficiency, 53.9 V Voc at 25 C, and 57.94 V cold Voc at -10 C (10 panels max per 600 V string).

STC Wattage
590.0 W
PTC Wattage
561.0 W
Voc @ 25C
53.9 V
Efficiency
23.41%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does JA Solar JAM72D40-590/MB-US Compare Against Peer CEC Listings?

Solar engineering breakdown for JA Solar JAM72D40-590/MB-US: PTC thermal retention, roof footprint, and cold Voc string bounds.

Measured at 590.0 W STC and 561.0 W PTC, JA Solar JAM72D40-590/MB-US sits +205.0 W vs all-CEC median (top 8.1%; higher than 91.9% of peers) among 21,677 listed modules. Power density reaches 234.1 W/m2 (3.50 percentage points above 19.91% CEC median). Higher 53.9 V open-circuit voltage caps 600 V residential strings at 10 panels at 14 F (-10 C), whereas 1,000 V commercial inverters handle up to 17 panels in series. Alternative peer Elin Energy (Sirius PV) ELNSM78M-HC-BF-590 rates 590.0 W.

Where Does JA Solar JAM72D40-590/MB-US Fall Across Listed CEC Models?

Distribution marker showing JA Solar JAM72D40-590/MB-US (590.0 W) relative to the 385.0 W all-CEC solar panel median.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where JA Solar JAM72D40-590/MB-US (590.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCJA Solar JAM72D40-: 590.0 W

What Dataset Percentiles Define JA Solar JAM72D40-590/MB-US?

Dataset percentiles tracking JA Solar JAM72D40-590/MB-US power output, thermal retention ratio, and aperture efficiency against 21,677 models.

JA Solar JAM72D40-590/MB-US Engineering BenchmarksPercentile comparison of JA Solar JAM72D40-590/MB-US wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage590.0 WPTC/STC Retention95.1%Module Efficiency23.41%

What Do the Dataset Ranks Show for JA Solar JAM72D40-590/MB-US?

Benchmark highlights for JA Solar JAM72D40-590/MB-US covering STC output, efficiency, 8 kW footprint, and OCPD breaker size.

Rank #1,597 / 21,677

Top 8.1% STC Output

590.0 W STC (+205.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #626

23.41% Aperture Efficiency

Power density 234.1 W/m2 (3.50 percentage points above 19.91% CEC median). PTC/STC ratio: 95.1% (rank #713).

NEC 690.7 Limit

10 Panels Max @ -10 C (600 V)

Cold Voc reaches 57.94 V at -10 C (579.4 V string) and 59.09 V at -20 C (10 max).

8 kW Reference Array

14 Panels = 8,260 W STC

Occupies 35.3 m2 (380 sq ft) producing 7,854 W PTC; NEC 690.8 OCPD floor is 21.92 A (25 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 53.9 * (1 + (-0.214/100) * (-10 - 25)) = 57.94 V | OCPD = 1.56 * 14.05 = 21.92 A

Inputs from CEC Modules.csv for JA Solar JAM72D40-590/MB-US: Voc=53.9 V, beta_Voc=-0.214%/C, Isc=14.05 A, STC=590.0 W, Area=2.52 m2.

Result: 10 panels max on 600 V (579.4 V); 14 panels for 8 kW (380 sq ft).

What Are the Published CEC Specifications for JA Solar JAM72D40-590/MB-US?

Official CEC datasheet figures for JA Solar JAM72D40-590/MB-US (Mono-c-Si) used in utility interconnection and permit reviews. Every reported metric links directly to federal public records or state regulatory filings with zero paid contractor placements.

Official California Energy Commission (NREL SAM) test parameters for JA Solar JAM72D40-590/MB-US.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 590.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 561.0 W (95.1% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 53.9 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 14.05 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 45.1 V / 13.09 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.214 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 23.41% (2.52 m2) Array roof footprint density
Cell Count & Technology 72 cells (Mono-c-Si) Bifacial glass-glass

How Many JA Solar JAM72D40-590/MB-US Panels Build a 6 kW, 8 kW, or 10 kW Array?

How many JA Solar JAM72D40-590/MB-US modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 11 6.49 kW 298 sq ft $1,624 $2,747
8 kW Class 14 8.26 kW 380 sq ft $2,067 $3,496
10 kW Class 17 10.03 kW 461 sq ft $2,510 $4,245

Which Sibling Wattage & Trim Variants Belong to This JA Solar Series?

Consolidated JA Solar wattage variants sharing the JA Solar JAM72D40-590/MB-US mechanical and cell layout. Inspect manufacturer nameplate documentation, UL listing boundaries, and utility rate schedules closely before ordering electrical hardware.

Sibling CEC listings grouped into the JA Solar JAM72D40-590/MB-US wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
JA Solar JAM72D40-585/MB-US 585.0 W 556.1 W 53.7 V 44.9 V 23.21%
JA Solar JAM72D40-590/MB-US 590.0 W 561.0 W 53.9 V 45.1 V 23.41%
JA Solar JAM72D40-595/MB-US 595.0 W 565.9 W 54.1 V 45.3 V 23.61%

How Many JA Solar JAM72D40-590/MB-US Modules Fit in a Cold-Weather String?

NEC 690.7(A) winter string table preventing overvoltage trips on JA Solar JAM72D40-590/MB-US (57.94 V at 14 F).

Computed from Voc=53.9V and beta_Voc=-0.214%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 59.09 V 10 panels 590.9 V 16 panels
-10 C (14 F) 57.94 V 10 panels 579.4 V 17 panels
0 C (32 F) 56.78 V 10 panels 567.8 V 17 panels
25 C (77 F STC) 53.9 V 11 panels 592.9 V 18 panels

Which Cross-Brand Solar Modules Compare Closest to JA Solar JAM72D40-590/MB-US?

Competing CEC solar panels closest to JA Solar JAM72D40-590/MB-US in nameplate wattage and Voc, starting with Elin Energy (Sirius PV) ELNSM78M-HC-BF-590.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
Elin Energy (Sirius PV) ELNSM78M-HC-BF-590
Elin Energy (Sirius PV)
590.0 W Tie (0 W) 53.83 V 21.3% 94.4%
Boviet Solar Technology Co Ltd BVM7613M-585-H-HC-BF
Boviet Solar Technology Co Ltd
585.0 W -5.0 W 54.07 V 20.89% 94.0%
Boviet Solar Technology Co Ltd BVM7613M-585-H-HC-BF-DG
Boviet Solar Technology Co Ltd
585.0 W -5.0 W 54.07 V 20.89% 94.1%
Aptos Solar Technology LLC DNA-144-BFN10-590W-DG
Aptos Solar Technology LLC
590.0 W Tie (0 W) 52.4 V 22.87% 95.0%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for JA Solar JAM72D40-590/MB-US?

Evaluate JA Solar JAM72D40-590/MB-US (590.0 W STC, 53.9 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), JA Solar JAM72D40-590/MB-US reaches 59.09 V per panel—exceeding 10 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 14 panels for an 8 kW build require 380 sq ft of unshaded roof plane — better matched to wide open ground racks or commercial flat roofs than tight residential roof hips.
  • 2026 tax credit baseline: cash residential installs of JA Solar JAM72D40-590/MB-US carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

JA Solar JAM72D40-590/MB-US 8 kW Residential Fit

Needs 14 modules (380 sq ft) with a 25 A string OCPD, offsetting ~$2,067/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 10 panels (-10 C) or 10 panels (-20 C), or compare Elin Energy (Sirius PV) ELNSM78M-HC-BF-590.

Bifacial / High-Heat Roof Check

Glass-glass bifacial cells capture rear albedo reflection over light ground gravel or white membranes. Real-world output tracks 561.0 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for JA Solar JAM72D40-590/MB-US by JA Solar grounded in CEC test data and NEC 690.7/690.8 limits.

How many JA Solar JAM72D40-590/MB-US panels fit on a 600 V winter solar string?

At -10 C (14 F), JA Solar JAM72D40-590/MB-US cold Voc rises from 53.9 V to 57.94 V (beta_Voc -0.214%/C), capping a 600 V string at 10 panels (579.4 V).

How much roof area does an 8 kW array of JA Solar JAM72D40-590/MB-US need?

An 8 kW DC system uses 14 JA Solar JAM72D40-590/MB-US modules (8,260 W STC / 7,854 W PTC), covering roughly 380 sq ft and saving ~$2,067/yr at 18.54 c/kWh.

How does JA Solar JAM72D40-590/MB-US compare against Elin Energy (Sirius PV) ELNSM78M-HC-BF-590?

JA Solar JAM72D40-590/MB-US outputs 590.0 W STC (53.9 V Voc, rank #1,597 of 21,677), while Elin Energy (Sirius PV) ELNSM78M-HC-BF-590 delivers 590.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.