JA Solar JAM72D20-440/MB is a 440.0 W STC (412.9 W PTC) Mono-c-Si solar module ranking #6,418 of 21,677 CEC listings (top 31.6%; higher than 68.4% of peers). It delivers 19.82% efficiency, 49.3 V Voc at 25 C, and 53.84 V cold Voc at -10 C (11 panels max per 600 V string).
- STC Wattage
- 440.0 W
- PTC Wattage
- 412.9 W
- Voc @ 25C
- 49.3 V
- Efficiency
- 19.82%
How Does JA Solar JAM72D20-440/MB Compare Against Peer CEC Listings?
CEC rank, roof space requirements, and NEC 690.7/690.8 limits for JA Solar JAM72D20-440/MB (Mono-c-Si) residential solar systems.
JA Solar JAM72D20-440/MB delivers 198.2 W/m2 (0.09 percentage points below 19.91% CEC median) and strong 93.8% PTC-to-STC heat retention (#5,632 of 21,677), placing it as a modern high-density residential and light-commercial module well-proportioned for residential pitched roofs needing 19 panels (454 sq ft) for an 8 kW array. At -4 F (-20 C), string voltage climbs to 55.13 V per unit, capping 600 V circuits at 10 panels. Compare specs directly with Bluesun Solar CoLtd BSM440M-72HBD (440.0 W).
Where Does JA Solar JAM72D20-440/MB Fall Across Listed CEC Models?
Comparison of JA Solar JAM72D20-440/MB (440.0 W STC) against all 21,677 California Energy Commission certified photovoltaic modules.
What Dataset Percentiles Define JA Solar JAM72D20-440/MB?
Relative ranking of JA Solar JAM72D20-440/MB across nameplate watts, 93.8% PTC thermal ratio, and module aperture efficiency.
What Do the Dataset Ranks Show for JA Solar JAM72D20-440/MB?
Summary of JA Solar JAM72D20-440/MB output rank, 8 kW array size (19 panels), efficiency rating, and 600 V string limit.
Top 31.6% STC Output
440.0 W STC (+55.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.
19.82% Aperture Efficiency
Power density 198.2 W/m2 (0.09 percentage points below 19.91% CEC median). PTC/STC ratio: 93.8% (rank #5,632).
11 Panels Max @ -10 C (600 V)
Cold Voc reaches 53.84 V at -10 C (592.2 V string) and 55.13 V at -20 C (10 max).
19 Panels = 8,360 W STC
Occupies 42.2 m2 (454 sq ft) producing 7,845 W PTC; NEC 690.8 OCPD floor is 17.67 A (20 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 49.3 * (1 + (-0.263/100) * (-10 - 25)) = 53.84 V | OCPD = 1.56 * 11.33 = 17.67 A
Inputs from CEC Modules.csv for JA Solar JAM72D20-440/MB: Voc=49.3 V, beta_Voc=-0.263%/C, Isc=11.33 A, STC=440.0 W, Area=2.22 m2.
Result: 11 panels max on 600 V (592.2 V); 19 panels for 8 kW (454 sq ft).
What Are the Published CEC Specifications for JA Solar JAM72D20-440/MB?
Complete CEC test sheet for JA Solar JAM72D20-440/MB including Isc (11.33 A), Voc (49.3 V), and thermal temperature coefficients.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 440.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 412.9 W (93.8% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 49.3 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 11.33 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 40.6 V / 10.84 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.263 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 19.82% (2.22 m2) | Array roof footprint density |
| Cell Count & Technology | 72 cells (Mono-c-Si) | Bifacial glass-glass |
How Many JA Solar JAM72D20-440/MB Panels Build a 6 kW, 8 kW, or 10 kW Array?
Residential array count and annual electric bill savings at 18.54 c/kWh US avg vs. California tariffs using JA Solar JAM72D20-440/MB.
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 14 | 6.16 kW | 335 sq ft | $1,542 | $2,607 |
| 8 kW Class | 19 | 8.36 kW | 454 sq ft | $2,092 | $3,538 |
| 10 kW Class | 23 | 10.12 kW | 550 sq ft | $2,533 | $4,283 |
Which Sibling Wattage & Trim Variants Belong to This JA Solar Series?
Related JA Solar power steps and black/silver trims consolidated into this JA Solar JAM72D20-440/MB series guide.
| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| JA Solar JAM72D20-435/MB | 435.0 W | 408.1 W | 49.15 V | 40.28 V | 19.59% |
| JA Solar JAM72D20-440/MB | 440.0 W | 412.9 W | 49.3 V | 40.6 V | 19.82% |
| JA Solar JAM72D20-445/MB | 445.0 W | 417.7 W | 49.45 V | 40.91 V | 20.05% |
How Many JA Solar JAM72D20-440/MB Modules Fit in a Cold-Weather String?
Verify freezing-morning voltage rise for JA Solar JAM72D20-440/MB (49.3 V STC) before wiring 600 V or 1,000 V strings.
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 55.13 V | 10 panels | 551.3 V | 18 panels |
| -10 C (14 F) | 53.84 V | 11 panels | 592.2 V | 18 panels |
| 0 C (32 F) | 52.54 V | 11 panels | 577.9 V | 19 panels |
| 25 C (77 F STC) | 49.3 V | 12 panels | 591.6 V | 20 panels |
Which Cross-Brand Solar Modules Compare Closest to JA Solar JAM72D20-440/MB?
Four comparable CEC modules such as Bluesun Solar CoLtd BSM440M-72HBD (440.0 W) for side-by-side solar quote checks. Always verify current state NEC adoption cycles, local utility interconnection tariffs, and panel busbar ratings before pulling project permits.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| Bluesun Solar CoLtd BSM440M-72HBD Bluesun Solar CoLtd |
440.0 W | Tie (0 W) | 50.0 V | 20.28% | 92.7% |
| Aptos Solar Technology LLC DNA-144-BF26-435W Aptos Solar Technology LLC |
435.0 W | -5.0 W | 49.38 V | 20.71% | 92.3% |
| Caterpillar Inc PVC435MB03H Caterpillar Inc |
435.0 W | -5.0 W | 49.1 V | 20.62% | 93.7% |
| CSI Solar Co Ltd CS3Y-440PB-AG CSI Solar Co Ltd |
440.0 W | Tie (0 W) | 51.2 V | 19.13% | 93.7% |
What Are the Design Limits and Best-Fit Uses for JA Solar JAM72D20-440/MB?
Evaluate JA Solar JAM72D20-440/MB (440.0 W STC, 49.3 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), JA Solar JAM72D20-440/MB reaches 55.13 V per panel—exceeding 10 panels in series voids 600 V inverter warranties.
- Footprint constraint: 19 panels for an 8 kW build require 454 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 19 panels (454 sq ft) for an 8 kW array.
- 2026 tax credit baseline: cash residential installs of JA Solar JAM72D20-440/MB carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
JA Solar JAM72D20-440/MB 8 kW Residential Fit
Needs 19 modules (454 sq ft) with a 20 A string OCPD, offsetting ~$2,092/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 11 panels (-10 C) or 10 panels (-20 C), or compare Bluesun Solar CoLtd BSM440M-72HBD.
Bifacial / High-Heat Roof Check
Glass-glass bifacial cells capture rear albedo reflection over light ground gravel or white membranes. Real-world output tracks 412.9 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for JA Solar JAM72D20-440/MB by JA Solar grounded in CEC test data and NEC 690.7/690.8 limits.
How many JA Solar JAM72D20-440/MB panels fit on a 600 V winter solar string?
At -10 C (14 F), JA Solar JAM72D20-440/MB cold Voc rises from 49.3 V to 53.84 V (beta_Voc -0.263%/C), capping a 600 V string at 11 panels (592.2 V).
How much roof area does an 8 kW array of JA Solar JAM72D20-440/MB need?
An 8 kW DC system uses 19 JA Solar JAM72D20-440/MB modules (8,360 W STC / 7,845 W PTC), covering roughly 454 sq ft and saving ~$2,092/yr at 18.54 c/kWh.
How does JA Solar JAM72D20-440/MB compare against Bluesun Solar CoLtd BSM440M-72HBD?
JA Solar JAM72D20-440/MB outputs 440.0 W STC (49.3 V Voc, rank #6,418 of 21,677), while Bluesun Solar CoLtd BSM440M-72HBD delivers 440.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)