JA Solar JAM72D10-395/MB is a 395.0 W STC (370.9 W PTC) Mono-c-Si solar module ranking #9,869 of 21,677 CEC listings (top 47.6%; higher than 52.4% of peers). It delivers 19.88% efficiency, 49.31 V Voc at 25 C, and 53.85 V cold Voc at -10 C (11 panels max per 600 V string).
- STC Wattage
- 395.0 W
- PTC Wattage
- 370.9 W
- Voc @ 25C
- 49.31 V
- Efficiency
- 19.88%
How Does JA Solar JAM72D10-395/MB Compare Against Peer CEC Listings?
CEC rank, roof space requirements, and NEC 690.7/690.8 limits for JA Solar JAM72D10-395/MB (Mono-c-Si) residential solar systems.
JA Solar JAM72D10-395/MB delivers 198.8 W/m2 (0.03 percentage points below 19.91% CEC median) and strong 93.9% PTC-to-STC heat retention (#5,210 of 21,677), placing it as a modern high-density residential and light-commercial module well-proportioned for residential pitched roofs needing 21 panels (449 sq ft) for an 8 kW array. At -4 F (-20 C), string voltage climbs to 55.15 V per unit, capping 600 V circuits at 10 panels. Compare specs directly with Aptos Solar Technology LLC DNA-144-BF23-395W (395.0 W).
Where Does JA Solar JAM72D10-395/MB Fall Across Listed CEC Models?
Comparison of JA Solar JAM72D10-395/MB (395.0 W STC) against all 21,677 California Energy Commission certified photovoltaic modules.
What Dataset Percentiles Define JA Solar JAM72D10-395/MB?
Relative ranking of JA Solar JAM72D10-395/MB across nameplate watts, 93.9% PTC thermal ratio, and module aperture efficiency.
What Do the Dataset Ranks Show for JA Solar JAM72D10-395/MB?
Summary of JA Solar JAM72D10-395/MB output rank, 8 kW array size (21 panels), efficiency rating, and 600 V string limit.
Top 47.6% STC Output
395.0 W STC (+10.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.
19.88% Aperture Efficiency
Power density 198.8 W/m2 (0.03 percentage points below 19.91% CEC median). PTC/STC ratio: 93.9% (rank #5,210).
11 Panels Max @ -10 C (600 V)
Cold Voc reaches 53.85 V at -10 C (592.4 V string) and 55.15 V at -20 C (10 max).
21 Panels = 8,295 W STC
Occupies 41.7 m2 (449 sq ft) producing 7,789 W PTC; NEC 690.8 OCPD floor is 15.72 A (20 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 49.31 * (1 + (-0.263/100) * (-10 - 25)) = 53.85 V | OCPD = 1.56 * 10.08 = 15.72 A
Inputs from CEC Modules.csv for JA Solar JAM72D10-395/MB: Voc=49.31 V, beta_Voc=-0.263%/C, Isc=10.08 A, STC=395.0 W, Area=1.987 m2.
Result: 11 panels max on 600 V (592.4 V); 21 panels for 8 kW (449 sq ft).
What Are the Published CEC Specifications for JA Solar JAM72D10-395/MB?
Complete CEC test sheet for JA Solar JAM72D10-395/MB including Isc (10.08 A), Voc (49.31 V), and thermal temperature coefficients.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 395.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 370.9 W (93.9% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 49.31 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 10.08 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 41.76 V / 9.46 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.263 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 19.88% (1.987 m2) | Array roof footprint density |
| Cell Count & Technology | 72 cells (Mono-c-Si) | Bifacial glass-glass |
How Many JA Solar JAM72D10-395/MB Panels Build a 6 kW, 8 kW, or 10 kW Array?
Residential array count and annual electric bill savings at 18.54 c/kWh US avg vs. California tariffs using JA Solar JAM72D10-395/MB.
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 16 | 6.32 kW | 342 sq ft | $1,582 | $2,675 |
| 8 kW Class | 21 | 8.29 kW | 449 sq ft | $2,075 | $3,509 |
| 10 kW Class | 26 | 10.27 kW | 556 sq ft | $2,570 | $4,347 |
Which Sibling Wattage & Trim Variants Belong to This JA Solar Series?
Related JA Solar power steps and black/silver trims consolidated into this JA Solar JAM72D10-395/MB series guide.
| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| JA Solar JAM72D10-390/MB | 390.0 W | 366.1 W | 49.05 V | 41.49 V | 19.63% |
| JA Solar JAM72D10-395/MB | 395.0 W | 370.9 W | 49.31 V | 41.76 V | 19.88% |
How Many JA Solar JAM72D10-395/MB Modules Fit in a Cold-Weather String?
Verify freezing-morning voltage rise for JA Solar JAM72D10-395/MB (49.31 V STC) before wiring 600 V or 1,000 V strings.
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 55.15 V | 10 panels | 551.5 V | 18 panels |
| -10 C (14 F) | 53.85 V | 11 panels | 592.4 V | 18 panels |
| 0 C (32 F) | 52.55 V | 11 panels | 578.0 V | 19 panels |
| 25 C (77 F STC) | 49.31 V | 12 panels | 591.7 V | 20 panels |
Which Cross-Brand Solar Modules Compare Closest to JA Solar JAM72D10-395/MB?
Four comparable CEC modules such as Aptos Solar Technology LLC DNA-144-BF23-395W (395.0 W) for side-by-side solar quote checks.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| Aptos Solar Technology LLC DNA-144-BF23-395W Aptos Solar Technology LLC |
395.0 W | Tie (0 W) | 48.26 V | 19.94% | 92.6% |
| Boviet Solar Technology Co Ltd BVM6612M-385L-H-BF Boviet Solar Technology Co Ltd |
385.0 W | -10.0 W | 48.45 V | 19.15% | 93.2% |
| Boviet Solar Technology Co Ltd BVM6612M-385L-H-BF-DG Boviet Solar Technology Co Ltd |
385.0 W | -10.0 W | 48.45 V | 19.06% | 93.6% |
| Boviet Solar Technology Co Ltd BVM6612M-385L-H-HC-BF Boviet Solar Technology Co Ltd |
385.0 W | -10.0 W | 48.45 V | 18.78% | 93.6% |
What Are the Design Limits and Best-Fit Uses for JA Solar JAM72D10-395/MB?
Evaluate JA Solar JAM72D10-395/MB (395.0 W STC, 49.31 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), JA Solar JAM72D10-395/MB reaches 55.15 V per panel—exceeding 10 panels in series voids 600 V inverter warranties.
- Footprint constraint: 21 panels for an 8 kW build require 449 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 21 panels (449 sq ft) for an 8 kW array.
- 2026 tax credit baseline: cash residential installs of JA Solar JAM72D10-395/MB carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
JA Solar JAM72D10-395/MB 8 kW Residential Fit
Needs 21 modules (449 sq ft) with a 20 A string OCPD, offsetting ~$2,075/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 11 panels (-10 C) or 10 panels (-20 C), or compare Aptos Solar Technology LLC DNA-144-BF23-395W.
Bifacial / High-Heat Roof Check
Glass-glass bifacial cells capture rear albedo reflection over light ground gravel or white membranes. Real-world output tracks 370.9 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for JA Solar JAM72D10-395/MB by JA Solar grounded in CEC test data and NEC 690.7/690.8 limits.
How many JA Solar JAM72D10-395/MB panels fit on a 600 V winter solar string?
At -10 C (14 F), JA Solar JAM72D10-395/MB cold Voc rises from 49.31 V to 53.85 V (beta_Voc -0.263%/C), capping a 600 V string at 11 panels (592.4 V).
How much roof area does an 8 kW array of JA Solar JAM72D10-395/MB need?
An 8 kW DC system uses 21 JA Solar JAM72D10-395/MB modules (8,295 W STC / 7,789 W PTC), covering roughly 449 sq ft and saving ~$2,075/yr at 18.54 c/kWh.
How does JA Solar JAM72D10-395/MB compare against Aptos Solar Technology LLC DNA-144-BF23-395W?
JA Solar JAM72D10-395/MB outputs 395.0 W STC (49.31 V Voc, rank #9,869 of 21,677), while Aptos Solar Technology LLC DNA-144-BF23-395W delivers 395.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)