JA Solar JAM72D09-385/BP is a 385.0 W STC (357.7 W PTC) Mono-c-Si solar module ranking #10,723 of 21,677 CEC listings (at all-CEC median; higher than 49.1% of peers). It delivers 19.51% efficiency, 49.11 V Voc at 25 C, and 53.75 V cold Voc at -10 C (11 panels max per 600 V string).

STC Wattage
385.0 W
PTC Wattage
357.7 W
Voc @ 25C
49.11 V
Efficiency
19.51%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does JA Solar JAM72D09-385/BP Compare Against Peer CEC Listings?

Engineering position of JA Solar JAM72D09-385/BP (385.0 W STC) vs. Boviet Solar Technology Co Ltd BVM6612M-385L-H-BF across 5,889 CEC Mono-c-Si solar modules.

Ranking #10,723 across 21,677 CEC solar panels (at all-CEC median; higher than 49.1% of peers), JA Solar JAM72D09-385/BP operates as a compact residential or specialty off-grid module sitting 25.0 W below the 410.0 W Mono-c-Si median. Higher 49.11 V open-circuit voltage caps 600 V residential strings at 11 panels at 14 F (-10 C). With strong 92.9% PTC-to-STC heat retention (#10,348 of 21,677), 21 panels occupy 446 sq ft and offset roughly $2,025/yr at average US rates (or $3,424/yr in California). Glass-glass bifacial cells capture rear albedo reflection over light ground gravel or white membranes.

Where Does JA Solar JAM72D09-385/BP Fall Across Listed CEC Models?

Plots JA Solar JAM72D09-385/BP at 385.0 W STC across all 21,677 California Energy Commission photovoltaic modules relative to the 385.0 W median.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where JA Solar JAM72D09-385/BP (385.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCJA Solar JAM72D09-: 385.0 W

What Dataset Percentiles Define JA Solar JAM72D09-385/BP?

Benchmarks JA Solar JAM72D09-385/BP on STC wattage, thermal PTC/STC retention, and 19.51 aperture conversion efficiency against CEC peers.

JA Solar JAM72D09-385/BP Engineering BenchmarksPercentile comparison of JA Solar JAM72D09-385/BP wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage385.0 WPTC/STC Retention92.9%Module Efficiency19.51%

What Do the Dataset Ranks Show for JA Solar JAM72D09-385/BP?

Key electrical performance ranks, roof area sizing, and NEC 690.7/690.8 design boundaries for JA Solar JAM72D09-385/BP by JA Solar.

Rank #10,723 / 21,677

385.0 W STC · Higher Than 49.1%

385.0 W STC (equal to all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #12,152

19.51% Aperture Efficiency

Power density 195.1 W/m2 (0.40 percentage points below 19.91% CEC median). PTC/STC ratio: 92.9% (rank #10,348).

NEC 690.7 Limit

11 Panels Max @ -10 C (600 V)

Cold Voc reaches 53.75 V at -10 C (591.2 V string) and 55.08 V at -20 C (10 max).

8 kW Reference Array

21 Panels = 8,085 W STC

Occupies 41.4 m2 (446 sq ft) producing 7,512 W PTC; NEC 690.8 OCPD floor is 15.74 A (20 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 49.11 * (1 + (-0.27/100) * (-10 - 25)) = 53.75 V | OCPD = 1.56 * 10.09 = 15.74 A

Inputs from CEC Modules.csv for JA Solar JAM72D09-385/BP: Voc=49.11 V, beta_Voc=-0.27%/C, Isc=10.09 A, STC=385.0 W, Area=1.973 m2.

Result: 11 panels max on 600 V (591.2 V); 21 panels for 8 kW (446 sq ft).

What Are the Published CEC Specifications for JA Solar JAM72D09-385/BP?

Laboratory test ratings recorded for JA Solar JAM72D09-385/BP (Mono-c-Si) in the official California Energy Commission NREL SAM equipment catalog.

Official California Energy Commission (NREL SAM) test parameters for JA Solar JAM72D09-385/BP.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 385.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 357.7 W (92.9% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 49.11 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 10.09 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 40.33 V / 9.55 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.27 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 19.51% (1.973 m2) Array roof footprint density
Cell Count & Technology 72 cells (Mono-c-Si) Bifacial glass-glass

How Many JA Solar JAM72D09-385/BP Panels Build a 6 kW, 8 kW, or 10 kW Array?

Panel counts, roof square footage (446 sq ft at 8 kW), and estimated Year-1 electric bill offset for JA Solar JAM72D09-385/BP.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 16 6.16 kW 340 sq ft $1,542 $2,607
8 kW Class 21 8.09 kW 446 sq ft $2,025 $3,424
10 kW Class 26 10.01 kW 552 sq ft $2,505 $4,236

Which Sibling Wattage & Trim Variants Belong to This JA Solar Series?

Sibling wattage bins and frame colors grouped with JA Solar JAM72D09-385/BP under JA Solar to prevent duplicate spec pages.

Sibling CEC listings grouped into the JA Solar JAM72D09-385/BP wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
JA Solar JAM72D09-375/BP 375.0 W 348.2 W 48.51 V 39.73 V 19.01%
JA Solar JAM72D09-380/BP 380.0 W 353.0 W 48.81 V 40.02 V 19.26%
JA Solar JAM72D09-385/BP 385.0 W 357.7 W 49.11 V 40.33 V 19.51%
JA Solar JAM72D09-390/BP 390.0 W 362.5 W 49.42 V 40.63 V 19.77%

How Many JA Solar JAM72D09-385/BP Modules Fit in a Cold-Weather String?

Cold-weather Voc escalation for JA Solar JAM72D09-385/BP (beta_Voc -0.27%/C) across 600 V residential and 1,000 V commercial inverters.

Computed from Voc=49.11V and beta_Voc=-0.27%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 55.08 V 10 panels 550.8 V 18 panels
-10 C (14 F) 53.75 V 11 panels 591.2 V 18 panels
0 C (32 F) 52.42 V 11 panels 576.6 V 19 panels
25 C (77 F STC) 49.11 V 12 panels 589.3 V 20 panels

Which Cross-Brand Solar Modules Compare Closest to JA Solar JAM72D09-385/BP?

Closest cross-brand CEC competitors to JA Solar JAM72D09-385/BP matched near 385.0 W STC and 49.11 V Voc, led by Boviet Solar Technology Co Ltd BVM6612M-385L-H-BF.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
Boviet Solar Technology Co Ltd BVM6612M-385L-H-BF
Boviet Solar Technology Co Ltd
385.0 W Tie (0 W) 48.45 V 19.15% 93.2%
Boviet Solar Technology Co Ltd BVM6612M-385L-H-BF-DG
Boviet Solar Technology Co Ltd
385.0 W Tie (0 W) 48.45 V 19.06% 93.6%
Boviet Solar Technology Co Ltd BVM6612M-385L-H-HC-BF
Boviet Solar Technology Co Ltd
385.0 W Tie (0 W) 48.45 V 18.78% 93.6%
Boviet Solar Technology Co Ltd BVM6612M-385L-H-HC-BF-DG
Boviet Solar Technology Co Ltd
385.0 W Tie (0 W) 48.45 V 18.78% 93.6%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for JA Solar JAM72D09-385/BP?

Evaluate JA Solar JAM72D09-385/BP (385.0 W STC, 49.11 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), JA Solar JAM72D09-385/BP reaches 55.08 V per panel—exceeding 10 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 21 panels for an 8 kW build require 446 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 21 panels (446 sq ft).
  • 2026 tax credit baseline: cash residential installs of JA Solar JAM72D09-385/BP carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

JA Solar JAM72D09-385/BP 8 kW Residential Fit

Needs 21 modules (446 sq ft) with a 20 A string OCPD, offsetting ~$2,025/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 11 panels (-10 C) or 10 panels (-20 C), or compare Boviet Solar Technology Co Ltd BVM6612M-385L-H-BF.

Bifacial / High-Heat Roof Check

Glass-glass bifacial cells capture rear albedo reflection over light ground gravel or white membranes. Real-world output tracks 357.7 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for JA Solar JAM72D09-385/BP by JA Solar grounded in CEC test data and NEC 690.7/690.8 limits.

How many JA Solar JAM72D09-385/BP panels fit on a 600 V winter solar string?

At -10 C (14 F), JA Solar JAM72D09-385/BP cold Voc rises from 49.11 V to 53.75 V (beta_Voc -0.27%/C), capping a 600 V string at 11 panels (591.2 V).

How much roof area does an 8 kW array of JA Solar JAM72D09-385/BP need?

An 8 kW DC system uses 21 JA Solar JAM72D09-385/BP modules (8,085 W STC / 7,512 W PTC), covering roughly 446 sq ft and saving ~$2,025/yr at 18.54 c/kWh.

How does JA Solar JAM72D09-385/BP compare against Boviet Solar Technology Co Ltd BVM6612M-385L-H-BF?

JA Solar JAM72D09-385/BP outputs 385.0 W STC (49.11 V Voc, rank #10,723 of 21,677), while Boviet Solar Technology Co Ltd BVM6612M-385L-H-BF delivers 385.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.