JA Solar JAM60S10-320/PR is a 320.0 W STC (299.4 W PTC) Mono-c-Si solar module ranking #14,944 of 21,677 CEC listings (below all-CEC median; higher than 29.0% of peers). It delivers 19.63% efficiency, 40.27 V Voc at 25 C, and 44.02 V cold Voc at -10 C (13 panels max per 600 V string).
- STC Wattage
- 320.0 W
- PTC Wattage
- 299.4 W
- Voc @ 25C
- 40.27 V
- Efficiency
- 19.63%
How Does JA Solar JAM60S10-320/PR Compare Against Peer CEC Listings?
How JA Solar JA Solar JAM60S10-320/PR handles rooftop heat (299.4 W PTC), 8 kW sizing, and cold winter string voltage.
JA Solar builds the JA Solar JAM60S10-320/PR (Mono-c-Si) as a compact residential or specialty off-grid module delivering 196.3 W/m2 (0.28 percentage points below 19.91% CEC median). Compared against GCL System Integration Technology Co Ltd GCL-M6/60320 (320.0 W), this model holds strong 93.6% PTC-to-STC heat retention (#6,726 of 21,677). Mid-range 40.27 V open-circuit voltage allows up to 13 panels per 600 V string at 14 F, while NEC 690.8 sets a 15.85 A overcurrent floor served by a 20 A breaker.
Where Does JA Solar JAM60S10-320/PR Fall Across Listed CEC Models?
Where JA Solar JAM60S10-320/PR (320.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.
What Dataset Percentiles Define JA Solar JAM60S10-320/PR?
Percentile placement of JA Solar JAM60S10-320/PR across power density (196.3 W/m2), thermal retention, and nameplate STC wattage.
What Do the Dataset Ranks Show for JA Solar JAM60S10-320/PR?
Four critical engineering numbers homeowners and solar installers check first when reviewing JA Solar JAM60S10-320/PR specifications. Cross-check local Authority Having Jurisdiction amendments and serving utility net-metering terms before finalizing project sizing.
320.0 W STC · Higher Than 29.0%
320.0 W STC (-65.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.
19.63% Aperture Efficiency
Power density 196.3 W/m2 (0.28 percentage points below 19.91% CEC median). PTC/STC ratio: 93.6% (rank #6,726).
13 Panels Max @ -10 C (600 V)
Cold Voc reaches 44.02 V at -10 C (572.3 V string) and 45.09 V at -20 C (13 max).
25 Panels = 8,000 W STC
Occupies 40.8 m2 (439 sq ft) producing 7,485 W PTC; NEC 690.8 OCPD floor is 15.85 A (20 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 40.27 * (1 + (-0.266/100) * (-10 - 25)) = 44.02 V | OCPD = 1.56 * 10.16 = 15.85 A
Inputs from CEC Modules.csv for JA Solar JAM60S10-320/PR: Voc=40.27 V, beta_Voc=-0.266%/C, Isc=10.16 A, STC=320.0 W, Area=1.63 m2.
Result: 13 panels max on 600 V (572.3 V); 25 panels for 8 kW (439 sq ft).
What Are the Published CEC Specifications for JA Solar JAM60S10-320/PR?
Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for JA Solar JAM60S10-320/PR.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 320.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 299.4 W (93.6% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 40.27 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 10.16 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 33.62 V / 9.52 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.266 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 19.63% (1.63 m2) | Array roof footprint density |
| Cell Count & Technology | 60 cells (Mono-c-Si) | Monofacial backsheet |
How Many JA Solar JAM60S10-320/PR Panels Build a 6 kW, 8 kW, or 10 kW Array?
Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using JA Solar JAM60S10-320/PR (320.0 W).
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 19 | 6.08 kW | 333 sq ft | $1,522 | $2,573 |
| 8 kW Class | 25 | 8.0 kW | 439 sq ft | $2,002 | $3,386 |
| 10 kW Class | 32 | 10.24 kW | 561 sq ft | $2,563 | $4,334 |
How Many JA Solar JAM60S10-320/PR Modules Fit in a Cold-Weather String?
Maximum series module counts for JA Solar JAM60S10-320/PR from 25 C down to -20 C (-4 F) under NEC 690.7.
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 45.09 V | 13 panels | 586.2 V | 22 panels |
| -10 C (14 F) | 44.02 V | 13 panels | 572.3 V | 22 panels |
| 0 C (32 F) | 42.95 V | 13 panels | 558.4 V | 23 panels |
| 25 C (77 F STC) | 40.27 V | 14 panels | 563.8 V | 24 panels |
Which Cross-Brand Solar Modules Compare Closest to JA Solar JAM60S10-320/PR?
Alternative CEC solar modules from competing brands near JA Solar JAM60S10-320/PR (320.0 W), including GCL System Integration Technology Co Ltd GCL-M6/60320.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| GCL System Integration Technology Co Ltd GCL-M6/60320 GCL System Integration Technology Co Ltd |
320.0 W | Tie (0 W) | 40.3 V | 19.63% | 91.3% |
| Dehui Solar Power (Vietnam) CoLtd DH-M860F 320W Dehui Solar Power (Vietnam) CoLtd |
320.0 W | Tie (0 W) | 40.2 V | 19.88% | 92.9% |
| CSI Solar Co Ltd CS3K-320MS CSI Solar Co Ltd |
320.0 W | Tie (0 W) | 40.1 V | 20.0% | 93.2% |
| Aptos Solar Technology LLC DNA-120-MF23-320W {Blk} Aptos Solar Technology LLC |
320.0 W | Tie (0 W) | 39.92 V | 18.96% | 90.7% |
What Are the Design Limits and Best-Fit Uses for JA Solar JAM60S10-320/PR?
Evaluate JA Solar JAM60S10-320/PR (320.0 W STC, 40.27 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), JA Solar JAM60S10-320/PR reaches 45.09 V per panel—exceeding 13 panels in series voids 600 V inverter warranties.
- Footprint constraint: 25 panels for an 8 kW build require 439 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 25 panels (439 sq ft).
- 2026 tax credit baseline: cash residential installs of JA Solar JAM60S10-320/PR carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
JA Solar JAM60S10-320/PR 8 kW Residential Fit
Needs 25 modules (439 sq ft) with a 20 A string OCPD, offsetting ~$2,002/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 13 panels (-10 C) or 13 panels (-20 C), or compare GCL System Integration Technology Co Ltd GCL-M6/60320.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 299.4 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for JA Solar JAM60S10-320/PR by JA Solar grounded in CEC test data and NEC 690.7/690.8 limits.
What fuse or breaker size does NEC 690.8 require for JA Solar JAM60S10-320/PR?
Multiplying JA Solar JAM60S10-320/PR's 10.16 A short-circuit current by 1.56 equals 15.85 A minimum ampacity, requiring at least a 20 A overcurrent fuse or breaker.
Can JA Solar JAM60S10-320/PR pair with microinverters instead of a 600 V string inverter?
Yes—if the microinverter DC input ceiling exceeds 44.02 V cold Voc at 14 F and handles 10.16 A Isc; string inverters cap JA Solar JAM60S10-320/PR at 13 panels on 600 V.
Is JA Solar JAM60S10-320/PR eligible for the 30% federal 25D solar credit in 2026?
No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of JA Solar JAM60S10-320/PR rely on utility bill offset (~$2,002/yr at 8 kW) rather than 25D.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)