JA Solar JAM54S30-410/MR — CEC Solar Module Specifications

Manufacturer: JA Solar Registry: CEC Verified Engineering Specification

JA Solar JAM54S30-410/MR is a 410.0 W STC (384.4 W PTC) Mono-c-Si solar module ranking #8,539 of 21,677 CEC listings (top 41.3%; higher than 58.7% of peers). It delivers 21.58% efficiency, 37.32 V Voc at 25 C, and 40.7 V cold Voc at -10 C (14 panels max per 600 V string).

STC Wattage
410.0 W
PTC Wattage
384.4 W
Voc @ 25C
37.32 V
Efficiency
21.58%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does JA Solar JAM54S30-410/MR Compare Against Peer CEC Listings?

Solar engineering breakdown for JA Solar JAM54S30-410/MR: PTC thermal retention, roof footprint, and cold Voc string bounds.

Measured at 410.0 W STC and 384.4 W PTC, JA Solar JAM54S30-410/MR sits +25.0 W vs all-CEC median (top 41.3%; higher than 58.7% of peers) among 21,677 listed modules. Power density reaches 215.8 W/m2 (1.67 percentage points above 19.91% CEC median). Lower 37.32 V string voltage fits 14 panels in series at 14 F and pairs easily with microinverters, whereas 1,000 V commercial inverters handle up to 24 panels in series. Alternative peer Aptos Solar Technology LLC DNA-108-MF10-410W rates 410.0 W.

Where Does JA Solar JAM54S30-410/MR Fall Across Listed CEC Models?

Distribution marker showing JA Solar JAM54S30-410/MR (410.0 W) relative to the 385.0 W all-CEC solar panel median.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where JA Solar JAM54S30-410/MR (410.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCJA Solar JAM54S30-: 410.0 W

What Dataset Percentiles Define JA Solar JAM54S30-410/MR?

Dataset percentiles tracking JA Solar JAM54S30-410/MR power output, thermal retention ratio, and aperture efficiency against 21,677 models.

JA Solar JAM54S30-410/MR Engineering BenchmarksPercentile comparison of JA Solar JAM54S30-410/MR wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage410.0 WPTC/STC Retention93.8%Module Efficiency21.58%

What Do the Dataset Ranks Show for JA Solar JAM54S30-410/MR?

Benchmark highlights for JA Solar JAM54S30-410/MR covering STC output, efficiency, 8 kW footprint, and OCPD breaker size.

Rank #8,539 / 21,677

Top 41.3% STC Output

410.0 W STC (+25.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #4,176

21.58% Aperture Efficiency

Power density 215.8 W/m2 (1.67 percentage points above 19.91% CEC median). PTC/STC ratio: 93.8% (rank #5,632).

NEC 690.7 Limit

14 Panels Max @ -10 C (600 V)

Cold Voc reaches 40.7 V at -10 C (569.8 V string) and 41.67 V at -20 C (14 max).

8 kW Reference Array

20 Panels = 8,200 W STC

Occupies 38.0 m2 (409 sq ft) producing 7,688 W PTC; NEC 690.8 OCPD floor is 21.76 A (25 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 37.32 * (1 + (-0.259/100) * (-10 - 25)) = 40.7 V | OCPD = 1.56 * 13.95 = 21.76 A

Inputs from CEC Modules.csv for JA Solar JAM54S30-410/MR: Voc=37.32 V, beta_Voc=-0.259%/C, Isc=13.95 A, STC=410.0 W, Area=1.9 m2.

Result: 14 panels max on 600 V (569.8 V); 20 panels for 8 kW (409 sq ft).

What Are the Published CEC Specifications for JA Solar JAM54S30-410/MR?

Official CEC datasheet figures for JA Solar JAM54S30-410/MR (Mono-c-Si) used in utility interconnection and permit reviews. Homeowners and permit reviewers can filter tables below to benchmark specific ratings, wiring ages, and code allowances side by side.

Official California Energy Commission (NREL SAM) test parameters for JA Solar JAM54S30-410/MR.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 410.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 384.4 W (93.8% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 37.32 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 13.95 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 31.45 V / 13.04 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.259 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 21.58% (1.9 m2) Array roof footprint density
Cell Count & Technology 54 cells (Mono-c-Si) Monofacial backsheet

How Many JA Solar JAM54S30-410/MR Panels Build a 6 kW, 8 kW, or 10 kW Array?

How many JA Solar JAM54S30-410/MR modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 15 6.15 kW 307 sq ft $1,539 $2,603
8 kW Class 20 8.2 kW 409 sq ft $2,052 $3,470
10 kW Class 25 10.25 kW 511 sq ft $2,565 $4,338

Which Sibling Wattage & Trim Variants Belong to This JA Solar Series?

Consolidated JA Solar wattage variants sharing the JA Solar JAM54S30-410/MR mechanical and cell layout. Cross-check local Authority Having Jurisdiction amendments and serving utility net-metering terms before finalizing project sizing.

Sibling CEC listings grouped into the JA Solar JAM54S30-410/MR wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
JA Solar JAM54S30-400/MR 400.0 W 374.7 W 37.07 V 30.01 V 21.05%
JA Solar JAM54S30-405/MR 405.0 W 379.6 W 37.23 V 31.21 V 21.32%
JA Solar JAM54S30-410/MR 410.0 W 384.4 W 37.32 V 31.45 V 21.58%
JA Solar JAM54S30-415/MR 415.0 W 389.2 W 37.45 V 31.61 V 21.84%

How Many JA Solar JAM54S30-410/MR Modules Fit in a Cold-Weather String?

NEC 690.7(A) winter string table preventing overvoltage trips on JA Solar JAM54S30-410/MR (40.7 V at 14 F).

Computed from Voc=37.32V and beta_Voc=-0.259%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 41.67 V 14 panels 583.4 V 23 panels
-10 C (14 F) 40.7 V 14 panels 569.8 V 24 panels
0 C (32 F) 39.74 V 15 panels 596.1 V 25 panels
25 C (77 F STC) 37.32 V 16 panels 597.1 V 26 panels

Which Cross-Brand Solar Modules Compare Closest to JA Solar JAM54S30-410/MR?

Competing CEC solar panels closest to JA Solar JAM54S30-410/MR in nameplate wattage and Voc, starting with Aptos Solar Technology LLC DNA-108-MF10-410W.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
Aptos Solar Technology LLC DNA-108-MF10-410W
Aptos Solar Technology LLC
410.0 W Tie (0 W) 37.32 V 21.03% 93.8%
CertainTeed CTM10410HC11-06
CertainTeed
410.0 W Tie (0 W) 37.32 V 21.03% 93.8%
Elin Energy (Sirius PV) ELNSM54M-HC-410
Elin Energy (Sirius PV)
410.0 W Tie (0 W) 37.32 V 21.13% 94.3%
Elin Energy (Sirius PV) ELNSM54M-HC-LV-410
Elin Energy (Sirius PV)
410.0 W Tie (0 W) 37.32 V 21.13% 94.3%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for JA Solar JAM54S30-410/MR?

Evaluate JA Solar JAM54S30-410/MR (410.0 W STC, 37.32 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), JA Solar JAM54S30-410/MR reaches 41.67 V per panel—exceeding 14 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 20 panels for an 8 kW build require 409 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 20 panels (409 sq ft) for an 8 kW array.
  • 2026 tax credit baseline: cash residential installs of JA Solar JAM54S30-410/MR carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

JA Solar JAM54S30-410/MR 8 kW Residential Fit

Needs 20 modules (409 sq ft) with a 25 A string OCPD, offsetting ~$2,052/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 14 panels (-10 C) or 14 panels (-20 C), or compare Aptos Solar Technology LLC DNA-108-MF10-410W.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 384.4 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for JA Solar JAM54S30-410/MR by JA Solar grounded in CEC test data and NEC 690.7/690.8 limits.

How many JA Solar JAM54S30-410/MR panels fit on a 600 V winter solar string?

At -10 C (14 F), JA Solar JAM54S30-410/MR cold Voc rises from 37.32 V to 40.7 V (beta_Voc -0.259%/C), capping a 600 V string at 14 panels (569.8 V).

How much roof area does an 8 kW array of JA Solar JAM54S30-410/MR need?

An 8 kW DC system uses 20 JA Solar JAM54S30-410/MR modules (8,200 W STC / 7,688 W PTC), covering roughly 409 sq ft and saving ~$2,052/yr at 18.54 c/kWh.

How does JA Solar JAM54S30-410/MR compare against Aptos Solar Technology LLC DNA-108-MF10-410W?

JA Solar JAM54S30-410/MR outputs 410.0 W STC (37.32 V Voc, rank #8,539 of 21,677), while Aptos Solar Technology LLC DNA-108-MF10-410W delivers 410.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?