HYUNDAI ENERGY SOLUTIONS CO LTD HiG-S365XG(BK) is a 365.0 W STC (338.6 W PTC) Mono-c-Si solar module ranking #12,044 of 21,677 CEC listings (below all-CEC median; higher than 42.9% of peers). It delivers 19.95% efficiency, 40.7 V Voc at 25 C, and 44.82 V cold Voc at -10 C (13 panels max per 600 V string).
- STC Wattage
- 365.0 W
- PTC Wattage
- 338.6 W
- Voc @ 25C
- 40.7 V
- Efficiency
- 19.95%
How Does HYUNDAI ENERGY SOLUTIONS CO LTD HiG-S365XG(BK) Compare Against Peer CEC Listings?
CEC rank, roof space requirements, and NEC 690.7/690.8 limits for HYUNDAI ENERGY SOLUTIONS CO LTD HiG-S365XG(BK) (Mono-c-Si) residential solar systems.
Homeowners evaluating HYUNDAI ENERGY SOLUTIONS CO LTD HiG-S365XG(BK) need 17 panels for 6 kW or 22 panels (433 sq ft) for an 8 kW array—useful on tight dormer roofs or battery cabins, though 8 kW requires 22 panels (433 sq ft). Under NEC 690.7(A), beta_Voc (-0.289%/C) pushes open-circuit voltage to 44.82 V at 14 F and 45.99 V at -4 F. Monofacial backsheet sealing targets flush dark shingle rooftop mounts.
Where Does HYUNDAI ENERGY SOLUTIONS CO LTD HiG-S365XG(BK) Fall Across Listed CEC Models?
Comparison of HYUNDAI ENERGY SOLUTIONS CO LTD HiG-S365XG(BK) (365.0 W STC) against all 21,677 California Energy Commission certified photovoltaic modules.
What Dataset Percentiles Define HYUNDAI ENERGY SOLUTIONS CO LTD HiG-S365XG(BK)?
Relative ranking of HYUNDAI ENERGY SOLUTIONS CO LTD HiG-S365XG(BK) across nameplate watts, 92.8% PTC thermal ratio, and module aperture efficiency.
What Do the Dataset Ranks Show for HYUNDAI ENERGY SOLUTIONS CO LTD HiG-S365XG(BK)?
Summary of HYUNDAI ENERGY SOLUTIONS CO LTD HiG-S365XG(BK) output rank, 8 kW array size (22 panels), efficiency rating, and 600 V string limit.
365.0 W STC · Higher Than 42.9%
365.0 W STC (-20.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.
19.95% Aperture Efficiency
Power density 199.5 W/m2 (0.04 percentage points above 19.91% CEC median). PTC/STC ratio: 92.8% (rank #10,898).
13 Panels Max @ -10 C (600 V)
Cold Voc reaches 44.82 V at -10 C (582.7 V string) and 45.99 V at -20 C (13 max).
22 Panels = 8,030 W STC
Occupies 40.3 m2 (433 sq ft) producing 7,449 W PTC; NEC 690.8 OCPD floor is 17.83 A (20 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 40.7 * (1 + (-0.289/100) * (-10 - 25)) = 44.82 V | OCPD = 1.56 * 11.43 = 17.83 A
Inputs from CEC Modules.csv for HYUNDAI ENERGY SOLUTIONS CO LTD HiG-S365XG(BK): Voc=40.7 V, beta_Voc=-0.289%/C, Isc=11.43 A, STC=365.0 W, Area=1.83 m2.
Result: 13 panels max on 600 V (582.7 V); 22 panels for 8 kW (433 sq ft).
What Are the Published CEC Specifications for HYUNDAI ENERGY SOLUTIONS CO LTD HiG-S365XG(BK)?
Complete CEC test sheet for HYUNDAI ENERGY SOLUTIONS CO LTD HiG-S365XG(BK) including Isc (11.43 A), Voc (40.7 V), and thermal temperature coefficients.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 365.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 338.6 W (92.8% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 40.7 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 11.43 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 34.2 V / 10.68 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.289 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 19.95% (1.83 m2) | Array roof footprint density |
| Cell Count & Technology | 60 cells (Mono-c-Si) | Monofacial backsheet |
How Many HYUNDAI ENERGY SOLUTIONS CO LTD HiG-S365XG(BK) Panels Build a 6 kW, 8 kW, or 10 kW Array?
Residential array count and annual electric bill savings at 18.54 c/kWh US avg vs. California tariffs using HYUNDAI ENERGY SOLUTIONS CO LTD HiG-S365XG(BK).
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 17 | 6.21 kW | 335 sq ft | $1,554 | $2,628 |
| 8 kW Class | 22 | 8.03 kW | 433 sq ft | $2,010 | $3,398 |
| 10 kW Class | 28 | 10.22 kW | 552 sq ft | $2,558 | $4,325 |
Which Sibling Wattage & Trim Variants Belong to This HYUNDAI ENERGY SOLUTIONS CO LTD Series?
Related HYUNDAI ENERGY SOLUTIONS CO LTD power steps and black/silver trims consolidated into this HYUNDAI ENERGY SOLUTIONS CO LTD HiG-S365XG(BK) series guide.
| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| HYUNDAI ENERGY SOLUTIONS CO LTD HiG-S355XG(BK) | 355.0 W | 329.1 W | 40.3 V | 33.8 V | 19.4% |
| HYUNDAI ENERGY SOLUTIONS CO LTD HiG-S360XG(BK) | 360.0 W | 333.9 W | 40.5 V | 34.0 V | 19.67% |
| HYUNDAI ENERGY SOLUTIONS CO LTD HiG-S365XG(BK) | 365.0 W | 338.6 W | 40.7 V | 34.2 V | 19.95% |
| HYUNDAI ENERGY SOLUTIONS CO LTD HiG-S370XG(BK) | 370.0 W | 343.4 W | 40.9 V | 34.4 V | 20.22% |
How Many HYUNDAI ENERGY SOLUTIONS CO LTD HiG-S365XG(BK) Modules Fit in a Cold-Weather String?
Verify freezing-morning voltage rise for HYUNDAI ENERGY SOLUTIONS CO LTD HiG-S365XG(BK) (40.7 V STC) before wiring 600 V or 1,000 V strings.
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 45.99 V | 13 panels | 597.9 V | 21 panels |
| -10 C (14 F) | 44.82 V | 13 panels | 582.7 V | 22 panels |
| 0 C (32 F) | 43.64 V | 13 panels | 567.3 V | 22 panels |
| 25 C (77 F STC) | 40.7 V | 14 panels | 569.8 V | 24 panels |
Which Cross-Brand Solar Modules Compare Closest to HYUNDAI ENERGY SOLUTIONS CO LTD HiG-S365XG(BK)?
Four comparable CEC modules such as Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M120-BHC-365W (365.0 W) for side-by-side solar quote checks.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M120-BHC-365W Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd |
365.0 W | Tie (0 W) | 40.7 V | 20.51% | 92.6% |
| Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M120-HC-365W Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd |
365.0 W | Tie (0 W) | 40.7 V | 20.17% | 92.3% |
| Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M120-HC-365W Black Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd |
365.0 W | Tie (0 W) | 40.7 V | 19.95% | 93.3% |
| Aptos Solar Technology LLC DNA-120-MF26-365W Aptos Solar Technology LLC |
365.0 W | Tie (0 W) | 40.7 V | 20.74% | 91.3% |
What Are the Design Limits and Best-Fit Uses for HYUNDAI ENERGY SOLUTIONS CO LTD HiG-S365XG(BK)?
Evaluate HYUNDAI ENERGY SOLUTIONS CO LTD HiG-S365XG(BK) (365.0 W STC, 40.7 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), HYUNDAI ENERGY SOLUTIONS CO LTD HiG-S365XG(BK) reaches 45.99 V per panel—exceeding 13 panels in series voids 600 V inverter warranties.
- Footprint constraint: 22 panels for an 8 kW build require 433 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 22 panels (433 sq ft).
- 2026 tax credit baseline: cash residential installs of HYUNDAI ENERGY SOLUTIONS CO LTD HiG-S365XG(BK) carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
HYUNDAI ENERGY SOLUTIONS CO LTD HiG-S365XG(BK) 8 kW Residential Fit
Needs 22 modules (433 sq ft) with a 20 A string OCPD, offsetting ~$2,010/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 13 panels (-10 C) or 13 panels (-20 C), or compare Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M120-BHC-365W.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 338.6 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for HYUNDAI ENERGY SOLUTIONS CO LTD HiG-S365XG(BK) by HYUNDAI ENERGY SOLUTIONS CO LTD grounded in CEC test data and NEC 690.7/690.8 limits.
Why is HYUNDAI ENERGY SOLUTIONS CO LTD HiG-S365XG(BK) PTC wattage (338.6 W) lower than STC (365.0 W)?
Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 338.6 W PTC (92.8% retention) across HYUNDAI ENERGY SOLUTIONS CO LTD HiG-S365XG(BK)'s 1.83 m2 aperture.
Who should skip HYUNDAI ENERGY SOLUTIONS CO LTD HiG-S365XG(BK) on a complex residential roof?
Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 22 HYUNDAI ENERGY SOLUTIONS CO LTD HiG-S365XG(BK) panels (433 sq ft) leave unusable roof gaps vs. Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M120-BHC-365W.
What is the 1,000 V commercial string limit for HYUNDAI ENERGY SOLUTIONS CO LTD HiG-S365XG(BK)?
On 1,000 V commercial inverters at -10 C (44.82 V cold Voc), HYUNDAI ENERGY SOLUTIONS CO LTD HiG-S365XG(BK) fits up to 22 panels per series string.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)