HYUNDAI ENERGY SOLUTIONS CO LTD HiA-S365XG(BK) is a 365.0 W STC (339.8 W PTC) Mono-c-Si solar module ranking #12,044 of 21,677 CEC listings (below all-CEC median; higher than 42.9% of peers). It delivers 20.04% efficiency, 40.59 V Voc at 25 C, and 44.61 V cold Voc at -10 C (13 panels max per 600 V string).
- STC Wattage
- 365.0 W
- PTC Wattage
- 339.8 W
- Voc @ 25C
- 40.59 V
- Efficiency
- 20.04%
How Does HYUNDAI ENERGY SOLUTIONS CO LTD HiA-S365XG(BK) Compare Against Peer CEC Listings?
Engineering position of HYUNDAI ENERGY SOLUTIONS CO LTD HiA-S365XG(BK) (365.0 W STC) vs. Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M120-BHC-365W across 5,889 CEC Mono-c-Si solar modules.
Built with 60 Mono-c-Si cells, HYUNDAI ENERGY SOLUTIONS CO LTD HiA-S365XG(BK) pairs strong 93.1% PTC-to-STC heat retention (#9,420 of 21,677) with 40.59 V nominal Voc. An 8 kW residential build (8,030 W DC, 7,476 W PTC) saves ~$2,010/yr at 18.54 c/kWh with zero federal 25D credit in 2026. Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Peer Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M120-BHC-365W offers a 365.0 W alternative.
Where Does HYUNDAI ENERGY SOLUTIONS CO LTD HiA-S365XG(BK) Fall Across Listed CEC Models?
Plots HYUNDAI ENERGY SOLUTIONS CO LTD HiA-S365XG(BK) at 365.0 W STC across all 21,677 California Energy Commission photovoltaic modules relative to the 385.0 W median.
What Dataset Percentiles Define HYUNDAI ENERGY SOLUTIONS CO LTD HiA-S365XG(BK)?
Benchmarks HYUNDAI ENERGY SOLUTIONS CO LTD HiA-S365XG(BK) on STC wattage, thermal PTC/STC retention, and 20.04 aperture conversion efficiency against CEC peers.
What Do the Dataset Ranks Show for HYUNDAI ENERGY SOLUTIONS CO LTD HiA-S365XG(BK)?
Key electrical performance ranks, roof area sizing, and NEC 690.7/690.8 design boundaries for HYUNDAI ENERGY SOLUTIONS CO LTD HiA-S365XG(BK) by HYUNDAI ENERGY SOLUTIONS CO LTD.
365.0 W STC · Higher Than 42.9%
365.0 W STC (-20.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.
20.04% Aperture Efficiency
Power density 200.3 W/m2 (0.13 percentage points above 19.91% CEC median). PTC/STC ratio: 93.1% (rank #9,420).
13 Panels Max @ -10 C (600 V)
Cold Voc reaches 44.61 V at -10 C (579.9 V string) and 45.76 V at -20 C (13 max).
22 Panels = 8,030 W STC
Occupies 40.1 m2 (431 sq ft) producing 7,476 W PTC; NEC 690.8 OCPD floor is 17.6 A (20 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 40.59 * (1 + (-0.283/100) * (-10 - 25)) = 44.61 V | OCPD = 1.56 * 11.28 = 17.6 A
Inputs from CEC Modules.csv for HYUNDAI ENERGY SOLUTIONS CO LTD HiA-S365XG(BK): Voc=40.59 V, beta_Voc=-0.283%/C, Isc=11.28 A, STC=365.0 W, Area=1.822 m2.
Result: 13 panels max on 600 V (579.9 V); 22 panels for 8 kW (431 sq ft).
What Are the Published CEC Specifications for HYUNDAI ENERGY SOLUTIONS CO LTD HiA-S365XG(BK)?
Laboratory test ratings recorded for HYUNDAI ENERGY SOLUTIONS CO LTD HiA-S365XG(BK) (Mono-c-Si) in the official California Energy Commission NREL SAM equipment catalog.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 365.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 339.8 W (93.1% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 40.59 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 11.28 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 33.92 V / 10.76 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.283 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 20.04% (1.822 m2) | Array roof footprint density |
| Cell Count & Technology | 60 cells (Mono-c-Si) | Monofacial backsheet |
How Many HYUNDAI ENERGY SOLUTIONS CO LTD HiA-S365XG(BK) Panels Build a 6 kW, 8 kW, or 10 kW Array?
Panel counts, roof square footage (431 sq ft at 8 kW), and estimated Year-1 electric bill offset for HYUNDAI ENERGY SOLUTIONS CO LTD HiA-S365XG(BK).
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 17 | 6.21 kW | 333 sq ft | $1,554 | $2,628 |
| 8 kW Class | 22 | 8.03 kW | 431 sq ft | $2,010 | $3,398 |
| 10 kW Class | 28 | 10.22 kW | 549 sq ft | $2,558 | $4,325 |
Which Sibling Wattage & Trim Variants Belong to This HYUNDAI ENERGY SOLUTIONS CO LTD Series?
Sibling wattage bins and frame colors grouped with HYUNDAI ENERGY SOLUTIONS CO LTD HiA-S365XG(BK) under HYUNDAI ENERGY SOLUTIONS CO LTD to prevent duplicate spec pages.
| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| HYUNDAI ENERGY SOLUTIONS CO LTD HiA-S355XG(BK) | 355.0 W | 330.2 W | 39.95 V | 33.21 V | 19.49% |
| HYUNDAI ENERGY SOLUTIONS CO LTD HiA-S360XG(BK) | 360.0 W | 335.0 W | 40.26 V | 33.58 V | 19.76% |
| HYUNDAI ENERGY SOLUTIONS CO LTD HiA-S365XG(BK) | 365.0 W | 339.8 W | 40.59 V | 33.92 V | 20.04% |
| HYUNDAI ENERGY SOLUTIONS CO LTD HiA-S370XG(BK) | 370.0 W | 344.6 W | 40.91 V | 34.26 V | 20.31% |
How Many HYUNDAI ENERGY SOLUTIONS CO LTD HiA-S365XG(BK) Modules Fit in a Cold-Weather String?
Cold-weather Voc escalation for HYUNDAI ENERGY SOLUTIONS CO LTD HiA-S365XG(BK) (beta_Voc -0.283%/C) across 600 V residential and 1,000 V commercial inverters.
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 45.76 V | 13 panels | 594.9 V | 21 panels |
| -10 C (14 F) | 44.61 V | 13 panels | 579.9 V | 22 panels |
| 0 C (32 F) | 43.46 V | 13 panels | 565.0 V | 23 panels |
| 25 C (77 F STC) | 40.59 V | 14 panels | 568.3 V | 24 panels |
Which Cross-Brand Solar Modules Compare Closest to HYUNDAI ENERGY SOLUTIONS CO LTD HiA-S365XG(BK)?
Closest cross-brand CEC competitors to HYUNDAI ENERGY SOLUTIONS CO LTD HiA-S365XG(BK) matched near 365.0 W STC and 40.59 V Voc, led by Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M120-BHC-365W.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M120-BHC-365W Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd |
365.0 W | Tie (0 W) | 40.7 V | 20.51% | 92.6% |
| Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M120-HC-365W Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd |
365.0 W | Tie (0 W) | 40.7 V | 20.17% | 92.3% |
| Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M120-HC-365W Black Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd |
365.0 W | Tie (0 W) | 40.7 V | 19.95% | 93.3% |
| Aptos Solar Technology LLC DNA-120-MF26-365W Aptos Solar Technology LLC |
365.0 W | Tie (0 W) | 40.7 V | 20.74% | 91.3% |
What Are the Design Limits and Best-Fit Uses for HYUNDAI ENERGY SOLUTIONS CO LTD HiA-S365XG(BK)?
Evaluate HYUNDAI ENERGY SOLUTIONS CO LTD HiA-S365XG(BK) (365.0 W STC, 40.59 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), HYUNDAI ENERGY SOLUTIONS CO LTD HiA-S365XG(BK) reaches 45.76 V per panel—exceeding 13 panels in series voids 600 V inverter warranties.
- Footprint constraint: 22 panels for an 8 kW build require 431 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 22 panels (431 sq ft).
- 2026 tax credit baseline: cash residential installs of HYUNDAI ENERGY SOLUTIONS CO LTD HiA-S365XG(BK) carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
HYUNDAI ENERGY SOLUTIONS CO LTD HiA-S365XG(BK) 8 kW Residential Fit
Needs 22 modules (431 sq ft) with a 20 A string OCPD, offsetting ~$2,010/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 13 panels (-10 C) or 13 panels (-20 C), or compare Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M120-BHC-365W.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 339.8 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for HYUNDAI ENERGY SOLUTIONS CO LTD HiA-S365XG(BK) by HYUNDAI ENERGY SOLUTIONS CO LTD grounded in CEC test data and NEC 690.7/690.8 limits.
What fuse or breaker size does NEC 690.8 require for HYUNDAI ENERGY SOLUTIONS CO LTD HiA-S365XG(BK)?
Multiplying HYUNDAI ENERGY SOLUTIONS CO LTD HiA-S365XG(BK)'s 11.28 A short-circuit current by 1.56 equals 17.6 A minimum ampacity, requiring at least a 20 A overcurrent fuse or breaker.
Can HYUNDAI ENERGY SOLUTIONS CO LTD HiA-S365XG(BK) pair with microinverters instead of a 600 V string inverter?
Yes—if the microinverter DC input ceiling exceeds 44.61 V cold Voc at 14 F and handles 11.28 A Isc; string inverters cap HYUNDAI ENERGY SOLUTIONS CO LTD HiA-S365XG(BK) at 13 panels on 600 V.
Is HYUNDAI ENERGY SOLUTIONS CO LTD HiA-S365XG(BK) eligible for the 30% federal 25D solar credit in 2026?
No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of HYUNDAI ENERGY SOLUTIONS CO LTD HiA-S365XG(BK) rely on utility bill offset (~$2,010/yr at 8 kW) rather than 25D.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)