HYUNDAI ENERGY SOLUTIONS CO LTD HiA-S365XG(BK) — CEC Solar Module Specifications

Manufacturer: HYUNDAI ENERGY SOLUTIONS CO LTD Registry: CEC Verified Engineering Specification

HYUNDAI ENERGY SOLUTIONS CO LTD HiA-S365XG(BK) is a 365.0 W STC (339.8 W PTC) Mono-c-Si solar module ranking #12,044 of 21,677 CEC listings (below all-CEC median; higher than 42.9% of peers). It delivers 20.04% efficiency, 40.59 V Voc at 25 C, and 44.61 V cold Voc at -10 C (13 panels max per 600 V string).

STC Wattage
365.0 W
PTC Wattage
339.8 W
Voc @ 25C
40.59 V
Efficiency
20.04%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does HYUNDAI ENERGY SOLUTIONS CO LTD HiA-S365XG(BK) Compare Against Peer CEC Listings?

Engineering position of HYUNDAI ENERGY SOLUTIONS CO LTD HiA-S365XG(BK) (365.0 W STC) vs. Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M120-BHC-365W across 5,889 CEC Mono-c-Si solar modules.

Built with 60 Mono-c-Si cells, HYUNDAI ENERGY SOLUTIONS CO LTD HiA-S365XG(BK) pairs strong 93.1% PTC-to-STC heat retention (#9,420 of 21,677) with 40.59 V nominal Voc. An 8 kW residential build (8,030 W DC, 7,476 W PTC) saves ~$2,010/yr at 18.54 c/kWh with zero federal 25D credit in 2026. Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Peer Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M120-BHC-365W offers a 365.0 W alternative.

Where Does HYUNDAI ENERGY SOLUTIONS CO LTD HiA-S365XG(BK) Fall Across Listed CEC Models?

Plots HYUNDAI ENERGY SOLUTIONS CO LTD HiA-S365XG(BK) at 365.0 W STC across all 21,677 California Energy Commission photovoltaic modules relative to the 385.0 W median.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where HYUNDAI ENERGY SOLUTIONS CO LTD HiA-S365XG(BK) (365.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCHYUNDAI ENERGY SOL: 365.0 W

What Dataset Percentiles Define HYUNDAI ENERGY SOLUTIONS CO LTD HiA-S365XG(BK)?

Benchmarks HYUNDAI ENERGY SOLUTIONS CO LTD HiA-S365XG(BK) on STC wattage, thermal PTC/STC retention, and 20.04 aperture conversion efficiency against CEC peers.

HYUNDAI ENERGY SOLUTIONS CO LTD HiA-S365XG(BK) Engineering BenchmarksPercentile comparison of HYUNDAI ENERGY SOLUTIONS CO LTD HiA-S365XG(BK) wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage365.0 WPTC/STC Retention93.1%Module Efficiency20.04%

What Do the Dataset Ranks Show for HYUNDAI ENERGY SOLUTIONS CO LTD HiA-S365XG(BK)?

Key electrical performance ranks, roof area sizing, and NEC 690.7/690.8 design boundaries for HYUNDAI ENERGY SOLUTIONS CO LTD HiA-S365XG(BK) by HYUNDAI ENERGY SOLUTIONS CO LTD.

Rank #12,044 / 21,677

365.0 W STC · Higher Than 42.9%

365.0 W STC (-20.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #10,397

20.04% Aperture Efficiency

Power density 200.3 W/m2 (0.13 percentage points above 19.91% CEC median). PTC/STC ratio: 93.1% (rank #9,420).

NEC 690.7 Limit

13 Panels Max @ -10 C (600 V)

Cold Voc reaches 44.61 V at -10 C (579.9 V string) and 45.76 V at -20 C (13 max).

8 kW Reference Array

22 Panels = 8,030 W STC

Occupies 40.1 m2 (431 sq ft) producing 7,476 W PTC; NEC 690.8 OCPD floor is 17.6 A (20 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 40.59 * (1 + (-0.283/100) * (-10 - 25)) = 44.61 V | OCPD = 1.56 * 11.28 = 17.6 A

Inputs from CEC Modules.csv for HYUNDAI ENERGY SOLUTIONS CO LTD HiA-S365XG(BK): Voc=40.59 V, beta_Voc=-0.283%/C, Isc=11.28 A, STC=365.0 W, Area=1.822 m2.

Result: 13 panels max on 600 V (579.9 V); 22 panels for 8 kW (431 sq ft).

What Are the Published CEC Specifications for HYUNDAI ENERGY SOLUTIONS CO LTD HiA-S365XG(BK)?

Laboratory test ratings recorded for HYUNDAI ENERGY SOLUTIONS CO LTD HiA-S365XG(BK) (Mono-c-Si) in the official California Energy Commission NREL SAM equipment catalog.

Official California Energy Commission (NREL SAM) test parameters for HYUNDAI ENERGY SOLUTIONS CO LTD HiA-S365XG(BK).
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 365.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 339.8 W (93.1% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 40.59 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 11.28 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 33.92 V / 10.76 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.283 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 20.04% (1.822 m2) Array roof footprint density
Cell Count & Technology 60 cells (Mono-c-Si) Monofacial backsheet

How Many HYUNDAI ENERGY SOLUTIONS CO LTD HiA-S365XG(BK) Panels Build a 6 kW, 8 kW, or 10 kW Array?

Panel counts, roof square footage (431 sq ft at 8 kW), and estimated Year-1 electric bill offset for HYUNDAI ENERGY SOLUTIONS CO LTD HiA-S365XG(BK).

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 17 6.21 kW 333 sq ft $1,554 $2,628
8 kW Class 22 8.03 kW 431 sq ft $2,010 $3,398
10 kW Class 28 10.22 kW 549 sq ft $2,558 $4,325

Which Sibling Wattage & Trim Variants Belong to This HYUNDAI ENERGY SOLUTIONS CO LTD Series?

Sibling wattage bins and frame colors grouped with HYUNDAI ENERGY SOLUTIONS CO LTD HiA-S365XG(BK) under HYUNDAI ENERGY SOLUTIONS CO LTD to prevent duplicate spec pages.

Sibling CEC listings grouped into the HYUNDAI ENERGY SOLUTIONS CO LTD HiA-S365XG(BK) wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
HYUNDAI ENERGY SOLUTIONS CO LTD HiA-S355XG(BK) 355.0 W 330.2 W 39.95 V 33.21 V 19.49%
HYUNDAI ENERGY SOLUTIONS CO LTD HiA-S360XG(BK) 360.0 W 335.0 W 40.26 V 33.58 V 19.76%
HYUNDAI ENERGY SOLUTIONS CO LTD HiA-S365XG(BK) 365.0 W 339.8 W 40.59 V 33.92 V 20.04%
HYUNDAI ENERGY SOLUTIONS CO LTD HiA-S370XG(BK) 370.0 W 344.6 W 40.91 V 34.26 V 20.31%

How Many HYUNDAI ENERGY SOLUTIONS CO LTD HiA-S365XG(BK) Modules Fit in a Cold-Weather String?

Cold-weather Voc escalation for HYUNDAI ENERGY SOLUTIONS CO LTD HiA-S365XG(BK) (beta_Voc -0.283%/C) across 600 V residential and 1,000 V commercial inverters.

Computed from Voc=40.59V and beta_Voc=-0.283%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 45.76 V 13 panels 594.9 V 21 panels
-10 C (14 F) 44.61 V 13 panels 579.9 V 22 panels
0 C (32 F) 43.46 V 13 panels 565.0 V 23 panels
25 C (77 F STC) 40.59 V 14 panels 568.3 V 24 panels

Which Cross-Brand Solar Modules Compare Closest to HYUNDAI ENERGY SOLUTIONS CO LTD HiA-S365XG(BK)?

Closest cross-brand CEC competitors to HYUNDAI ENERGY SOLUTIONS CO LTD HiA-S365XG(BK) matched near 365.0 W STC and 40.59 V Voc, led by Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M120-BHC-365W.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M120-BHC-365W
Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd
365.0 W Tie (0 W) 40.7 V 20.51% 92.6%
Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M120-HC-365W
Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd
365.0 W Tie (0 W) 40.7 V 20.17% 92.3%
Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M120-HC-365W Black
Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd
365.0 W Tie (0 W) 40.7 V 19.95% 93.3%
Aptos Solar Technology LLC DNA-120-MF26-365W
Aptos Solar Technology LLC
365.0 W Tie (0 W) 40.7 V 20.74% 91.3%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for HYUNDAI ENERGY SOLUTIONS CO LTD HiA-S365XG(BK)?

Evaluate HYUNDAI ENERGY SOLUTIONS CO LTD HiA-S365XG(BK) (365.0 W STC, 40.59 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), HYUNDAI ENERGY SOLUTIONS CO LTD HiA-S365XG(BK) reaches 45.76 V per panel—exceeding 13 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 22 panels for an 8 kW build require 431 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 22 panels (431 sq ft).
  • 2026 tax credit baseline: cash residential installs of HYUNDAI ENERGY SOLUTIONS CO LTD HiA-S365XG(BK) carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

HYUNDAI ENERGY SOLUTIONS CO LTD HiA-S365XG(BK) 8 kW Residential Fit

Needs 22 modules (431 sq ft) with a 20 A string OCPD, offsetting ~$2,010/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 13 panels (-10 C) or 13 panels (-20 C), or compare Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M120-BHC-365W.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 339.8 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for HYUNDAI ENERGY SOLUTIONS CO LTD HiA-S365XG(BK) by HYUNDAI ENERGY SOLUTIONS CO LTD grounded in CEC test data and NEC 690.7/690.8 limits.

What fuse or breaker size does NEC 690.8 require for HYUNDAI ENERGY SOLUTIONS CO LTD HiA-S365XG(BK)?

Multiplying HYUNDAI ENERGY SOLUTIONS CO LTD HiA-S365XG(BK)'s 11.28 A short-circuit current by 1.56 equals 17.6 A minimum ampacity, requiring at least a 20 A overcurrent fuse or breaker.

Can HYUNDAI ENERGY SOLUTIONS CO LTD HiA-S365XG(BK) pair with microinverters instead of a 600 V string inverter?

Yes—if the microinverter DC input ceiling exceeds 44.61 V cold Voc at 14 F and handles 11.28 A Isc; string inverters cap HYUNDAI ENERGY SOLUTIONS CO LTD HiA-S365XG(BK) at 13 panels on 600 V.

Is HYUNDAI ENERGY SOLUTIONS CO LTD HiA-S365XG(BK) eligible for the 30% federal 25D solar credit in 2026?

No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of HYUNDAI ENERGY SOLUTIONS CO LTD HiA-S365XG(BK) rely on utility bill offset (~$2,010/yr at 8 kW) rather than 25D.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.