Hyperion Solar HY-WH108P8-410 is a 410.0 W STC (380.5 W PTC) Mono-c-Si solar module ranking #8,539 of 21,677 CEC listings (top 41.3%; higher than 58.7% of peers). It delivers 21.03% efficiency, 37.32 V Voc at 25 C, and 41.21 V cold Voc at -10 C (14 panels max per 600 V string).
- STC Wattage
- 410.0 W
- PTC Wattage
- 380.5 W
- Voc @ 25C
- 37.32 V
- Efficiency
- 21.03%
How Does Hyperion Solar HY-WH108P8-410 Compare Against Peer CEC Listings?
How Hyperion Solar Hyperion Solar HY-WH108P8-410 handles rooftop heat (380.5 W PTC), 8 kW sizing, and cold winter string voltage.
Hyperion Solar builds the Hyperion Solar HY-WH108P8-410 (Mono-c-Si) as a modern high-density residential and light-commercial module delivering 210.3 W/m2 (1.12 percentage points above 19.91% CEC median). Compared against Aptos Solar Technology LLC DNA-108-MF10-410W (410.0 W), this model holds strong 92.8% PTC-to-STC heat retention (#10,898 of 21,677). Lower 37.32 V string voltage fits 14 panels in series at 14 F and pairs easily with microinverters, while NEC 690.8 sets a 21.76 A overcurrent floor served by a 25 A breaker.
Where Does Hyperion Solar HY-WH108P8-410 Fall Across Listed CEC Models?
Where Hyperion Solar HY-WH108P8-410 (410.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.
What Dataset Percentiles Define Hyperion Solar HY-WH108P8-410?
Percentile placement of Hyperion Solar HY-WH108P8-410 across power density (210.3 W/m2), thermal retention, and nameplate STC wattage.
What Do the Dataset Ranks Show for Hyperion Solar HY-WH108P8-410?
Four critical engineering numbers homeowners and solar installers check first when reviewing Hyperion Solar HY-WH108P8-410 specifications. All figures trace directly to published federal energy filings, state electrical boards, CEC datasheets, and NFPA 70 NEC tables.
Top 41.3% STC Output
410.0 W STC (+25.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.
21.03% Aperture Efficiency
Power density 210.3 W/m2 (1.12 percentage points above 19.91% CEC median). PTC/STC ratio: 92.8% (rank #10,898).
14 Panels Max @ -10 C (600 V)
Cold Voc reaches 41.21 V at -10 C (576.9 V string) and 42.32 V at -20 C (14 max).
20 Panels = 8,200 W STC
Occupies 39.0 m2 (420 sq ft) producing 7,610 W PTC; NEC 690.8 OCPD floor is 21.76 A (25 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 37.32 * (1 + (-0.298/100) * (-10 - 25)) = 41.21 V | OCPD = 1.56 * 13.95 = 21.76 A
Inputs from CEC Modules.csv for Hyperion Solar HY-WH108P8-410: Voc=37.32 V, beta_Voc=-0.298%/C, Isc=13.95 A, STC=410.0 W, Area=1.95 m2.
Result: 14 panels max on 600 V (576.9 V); 20 panels for 8 kW (420 sq ft).
What Are the Published CEC Specifications for Hyperion Solar HY-WH108P8-410?
Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for Hyperion Solar HY-WH108P8-410.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 410.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 380.5 W (92.8% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 37.32 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 13.95 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 31.45 V / 13.04 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.298 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 21.03% (1.95 m2) | Array roof footprint density |
| Cell Count & Technology | 54 cells (Mono-c-Si) | Monofacial backsheet |
How Many Hyperion Solar HY-WH108P8-410 Panels Build a 6 kW, 8 kW, or 10 kW Array?
Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using Hyperion Solar HY-WH108P8-410 (410.0 W).
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 15 | 6.15 kW | 315 sq ft | $1,539 | $2,603 |
| 8 kW Class | 20 | 8.2 kW | 420 sq ft | $2,052 | $3,470 |
| 10 kW Class | 25 | 10.25 kW | 525 sq ft | $2,565 | $4,338 |
Which Sibling Wattage & Trim Variants Belong to This Hyperion Solar Series?
All closely matched Hyperion Solar wattages and cosmetic trims sharing the Hyperion Solar HY-WH108P8-410 architecture. Review related calculators, peer benchmarks, and source citations below to validate design assumptions for your electrical service.
| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| Hyperion Solar HY-WH108P8-400 | 400.0 W | 371.0 W | 37.07 V | 31.01 V | 20.51% |
| Hyperion Solar HY-WH108P8-405 | 405.0 W | 375.8 W | 37.23 V | 31.21 V | 20.77% |
| Hyperion Solar HY-WH108P8-410 | 410.0 W | 380.5 W | 37.32 V | 31.45 V | 21.03% |
| Hyperion Solar HY-WH108P8-415 | 415.0 W | 385.3 W | 37.45 V | 31.61 V | 21.28% |
How Many Hyperion Solar HY-WH108P8-410 Modules Fit in a Cold-Weather String?
Maximum series module counts for Hyperion Solar HY-WH108P8-410 from 25 C down to -20 C (-4 F) under NEC 690.7.
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 42.32 V | 14 panels | 592.5 V | 23 panels |
| -10 C (14 F) | 41.21 V | 14 panels | 576.9 V | 24 panels |
| 0 C (32 F) | 40.1 V | 14 panels | 561.4 V | 24 panels |
| 25 C (77 F STC) | 37.32 V | 16 panels | 597.1 V | 26 panels |
Which Cross-Brand Solar Modules Compare Closest to Hyperion Solar HY-WH108P8-410?
Alternative CEC solar modules from competing brands near Hyperion Solar HY-WH108P8-410 (410.0 W), including Aptos Solar Technology LLC DNA-108-MF10-410W.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| Aptos Solar Technology LLC DNA-108-MF10-410W Aptos Solar Technology LLC |
410.0 W | Tie (0 W) | 37.32 V | 21.03% | 93.8% |
| CertainTeed CTM10410HC11-06 CertainTeed |
410.0 W | Tie (0 W) | 37.32 V | 21.03% | 93.8% |
| Elin Energy (Sirius PV) ELNSM54M-HC-410 Elin Energy (Sirius PV) |
410.0 W | Tie (0 W) | 37.32 V | 21.13% | 94.3% |
| Elin Energy (Sirius PV) ELNSM54M-HC-LV-410 Elin Energy (Sirius PV) |
410.0 W | Tie (0 W) | 37.32 V | 21.13% | 94.3% |
What Are the Design Limits and Best-Fit Uses for Hyperion Solar HY-WH108P8-410?
Evaluate Hyperion Solar HY-WH108P8-410 (410.0 W STC, 37.32 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), Hyperion Solar HY-WH108P8-410 reaches 42.32 V per panel—exceeding 14 panels in series voids 600 V inverter warranties.
- Footprint constraint: 20 panels for an 8 kW build require 420 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 20 panels (420 sq ft) for an 8 kW array.
- 2026 tax credit baseline: cash residential installs of Hyperion Solar HY-WH108P8-410 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
Hyperion Solar HY-WH108P8-410 8 kW Residential Fit
Needs 20 modules (420 sq ft) with a 25 A string OCPD, offsetting ~$2,052/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 14 panels (-10 C) or 14 panels (-20 C), or compare Aptos Solar Technology LLC DNA-108-MF10-410W.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 380.5 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for Hyperion Solar HY-WH108P8-410 by Hyperion Solar grounded in CEC test data and NEC 690.7/690.8 limits.
What fuse or breaker size does NEC 690.8 require for Hyperion Solar HY-WH108P8-410?
Multiplying Hyperion Solar HY-WH108P8-410's 13.95 A short-circuit current by 1.56 equals 21.76 A minimum ampacity, requiring at least a 25 A overcurrent fuse or breaker.
Can Hyperion Solar HY-WH108P8-410 pair with microinverters instead of a 600 V string inverter?
Yes—if the microinverter DC input ceiling exceeds 41.21 V cold Voc at 14 F and handles 13.95 A Isc; string inverters cap Hyperion Solar HY-WH108P8-410 at 14 panels on 600 V.
Is Hyperion Solar HY-WH108P8-410 eligible for the 30% federal 25D solar credit in 2026?
No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of Hyperion Solar HY-WH108P8-410 rely on utility bill offset (~$2,052/yr at 8 kW) rather than 25D.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)