Skip to main content
WireAndSun
Calculators
CEC PV Module

Hyperion Solar HY-DH120P8-455-T — CEC Solar Module Specifications

Manufacturer: Hyperion Solar Registry: CEC Verified Engineering Specification

Hyperion Solar HY-DH120P8-455-T is a 455.0 W STC (423.1 W PTC) Mono-c-Si solar module ranking #5,417 of 21,677 CEC listings (top 26.2%; higher than 73.8% of peers). It delivers 21.06% efficiency, 41.36 V Voc at 25 C, and 45.8 V cold Voc at -10 C (13 panels max per 600 V string).

STC Wattage
455.0 W
PTC Wattage
423.1 W
Voc @ 25C
41.36 V
Efficiency
21.06%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does Hyperion Solar HY-DH120P8-455-T Compare Against Peer CEC Listings?

CEC rank, roof space requirements, and NEC 690.7/690.8 limits for Hyperion Solar HY-DH120P8-455-T (Mono-c-Si) residential solar systems.

Homeowners evaluating Hyperion Solar HY-DH120P8-455-T need 14 panels for 6 kW or 18 panels (419 sq ft) for an 8 kW array—well-proportioned for residential pitched roofs needing 18 panels (419 sq ft) for an 8 kW array. Under NEC 690.7(A), beta_Voc (-0.307%/C) pushes open-circuit voltage to 45.8 V at 14 F and 47.07 V at -4 F. Glass-glass bifacial cells capture rear albedo reflection over light ground gravel or white membranes.

Where Does Hyperion Solar HY-DH120P8-455-T Fall Across Listed CEC Models?

Comparison of Hyperion Solar HY-DH120P8-455-T (455.0 W STC) against all 21,677 California Energy Commission certified photovoltaic modules. Published percentiles compare local state, county, metro, and certified equipment metrics against nationwide residential electrical baselines.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where Hyperion Solar HY-DH120P8-455-T (455.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCHyperion Solar HY-: 455.0 W

What Dataset Percentiles Define Hyperion Solar HY-DH120P8-455-T?

Relative ranking of Hyperion Solar HY-DH120P8-455-T across nameplate watts, 93.0% PTC thermal ratio, and module aperture efficiency. All figures trace directly to published federal energy filings, state electrical boards, CEC datasheets, and NFPA 70 NEC tables.

Hyperion Solar HY-DH120P8-455-T Engineering BenchmarksPercentile comparison of Hyperion Solar HY-DH120P8-455-T wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage455.0 WPTC/STC Retention93.0%Module Efficiency21.06%

What Do the Dataset Ranks Show for Hyperion Solar HY-DH120P8-455-T?

Summary of Hyperion Solar HY-DH120P8-455-T output rank, 8 kW array size (18 panels), efficiency rating, and 600 V string limit.

Rank #5,417 / 21,677

Top 26.2% STC Output

455.0 W STC (+70.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #6,104

21.06% Aperture Efficiency

Power density 210.6 W/m2 (1.15 percentage points above 19.91% CEC median). PTC/STC ratio: 93.0% (rank #9,879).

NEC 690.7 Limit

13 Panels Max @ -10 C (600 V)

Cold Voc reaches 45.8 V at -10 C (595.4 V string) and 47.07 V at -20 C (12 max).

8 kW Reference Array

18 Panels = 8,190 W STC

Occupies 38.9 m2 (419 sq ft) producing 7,616 W PTC; NEC 690.8 OCPD floor is 21.76 A (25 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 41.36 * (1 + (-0.307/100) * (-10 - 25)) = 45.8 V | OCPD = 1.56 * 13.95 = 21.76 A

Inputs from CEC Modules.csv for Hyperion Solar HY-DH120P8-455-T: Voc=41.36 V, beta_Voc=-0.307%/C, Isc=13.95 A, STC=455.0 W, Area=2.16 m2.

Result: 13 panels max on 600 V (595.4 V); 18 panels for 8 kW (419 sq ft).

What Are the Published CEC Specifications for Hyperion Solar HY-DH120P8-455-T?

Complete CEC test sheet for Hyperion Solar HY-DH120P8-455-T including Isc (13.95 A), Voc (41.36 V), and thermal temperature coefficients.

Official California Energy Commission (NREL SAM) test parameters for Hyperion Solar HY-DH120P8-455-T.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 455.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 423.1 W (93.0% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 41.36 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 13.95 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 34.9 V / 13.04 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.307 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 21.06% (2.16 m2) Array roof footprint density
Cell Count & Technology 60 cells (Mono-c-Si) Bifacial glass-glass

How Many Hyperion Solar HY-DH120P8-455-T Panels Build a 6 kW, 8 kW, or 10 kW Array?

Residential array count and annual electric bill savings at 18.54 c/kWh US avg vs. California tariffs using Hyperion Solar HY-DH120P8-455-T.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 14 6.37 kW 326 sq ft $1,594 $2,696
8 kW Class 18 8.19 kW 419 sq ft $2,050 $3,466
10 kW Class 22 10.01 kW 512 sq ft $2,505 $4,236

Which Sibling Wattage & Trim Variants Belong to This Hyperion Solar Series?

Related Hyperion Solar power steps and black/silver trims consolidated into this Hyperion Solar HY-DH120P8-455-T series guide. Regional housing vintage, storm hazard frequency, and wholesale utility prices directly govern residential upgrade payback across jurisdictions.

Sibling CEC listings grouped into the Hyperion Solar HY-DH120P8-455-T wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
Hyperion Solar HY-DH120P8-450-T 450.0 W 418.3 W 41.2 V 34.73 V 20.83%
Hyperion Solar HY-DH120P8-455-T 455.0 W 423.1 W 41.36 V 34.9 V 21.06%
Hyperion Solar HY-DH120P8-460-T 460.0 W 427.9 W 41.54 V 35.04 V 21.3%

How Many Hyperion Solar HY-DH120P8-455-T Modules Fit in a Cold-Weather String?

Verify freezing-morning voltage rise for Hyperion Solar HY-DH120P8-455-T (41.36 V STC) before wiring 600 V or 1,000 V strings.

Computed from Voc=41.36V and beta_Voc=-0.307%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 47.07 V 12 panels 564.8 V 21 panels
-10 C (14 F) 45.8 V 13 panels 595.4 V 21 panels
0 C (32 F) 44.53 V 13 panels 578.9 V 22 panels
25 C (77 F STC) 41.36 V 14 panels 579.0 V 24 panels

Which Cross-Brand Solar Modules Compare Closest to Hyperion Solar HY-DH120P8-455-T?

Four comparable CEC modules such as ALTERNATIVE ENERGY (AE) SOLAR CO LTD AE455MD-120BS (455.0 W) for side-by-side solar quote checks.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
ALTERNATIVE ENERGY (AE) SOLAR CO LTD AE455MD-120BS
ALTERNATIVE ENERGY (AE) SOLAR CO LTD
455.0 W Tie (0 W) 41.5 V 21.26% 92.7%
Aptos Solar Technology LLC DNA-120-BF10-455W
Aptos Solar Technology LLC
455.0 W Tie (0 W) 41.51 V 21.26% 92.7%
Dehui Solar Power (Vietnam) CoLtd DH-M160T 455W
Dehui Solar Power (Vietnam) CoLtd
455.0 W Tie (0 W) 41.51 V 21.26% 92.7%
Aptos Solar Technology LLC DNA-120-BF10-455W-USAptos1
Aptos Solar Technology LLC
455.0 W Tie (0 W) 41.65 V 21.26% 94.4%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for Hyperion Solar HY-DH120P8-455-T?

Evaluate Hyperion Solar HY-DH120P8-455-T (455.0 W STC, 41.36 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), Hyperion Solar HY-DH120P8-455-T reaches 47.07 V per panel—exceeding 12 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 18 panels for an 8 kW build require 419 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 18 panels (419 sq ft) for an 8 kW array.
  • 2026 tax credit baseline: cash residential installs of Hyperion Solar HY-DH120P8-455-T carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

Hyperion Solar HY-DH120P8-455-T 8 kW Residential Fit

Needs 18 modules (419 sq ft) with a 25 A string OCPD, offsetting ~$2,050/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 13 panels (-10 C) or 12 panels (-20 C), or compare ALTERNATIVE ENERGY (AE) SOLAR CO LTD AE455MD-120BS.

Bifacial / High-Heat Roof Check

Glass-glass bifacial cells capture rear albedo reflection over light ground gravel or white membranes. Real-world output tracks 423.1 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Hyperion Solar HY-DH120P8-455-T by Hyperion Solar grounded in CEC test data and NEC 690.7/690.8 limits.

Why is Hyperion Solar HY-DH120P8-455-T PTC wattage (423.1 W) lower than STC (455.0 W)?

Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 423.1 W PTC (93.0% retention) across Hyperion Solar HY-DH120P8-455-T's 2.16 m2 aperture.

Who should skip Hyperion Solar HY-DH120P8-455-T on a complex residential roof?

Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 18 Hyperion Solar HY-DH120P8-455-T panels (419 sq ft) leave unusable roof gaps vs. ALTERNATIVE ENERGY (AE) SOLAR CO LTD AE455MD-120BS.

What is the 1,000 V commercial string limit for Hyperion Solar HY-DH120P8-455-T?

On 1,000 V commercial inverters at -10 C (45.8 V cold Voc), Hyperion Solar HY-DH120P8-455-T fits up to 21 panels per series string. Review current municipal Authority Having Jurisdiction (AHJ) code amendments affecting Hyperion Solar HY-DH120P8-455-T.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.