Hyperion Solar HY-DH120P8-440 is a 440.0 W STC (408.8 W PTC) Mono-c-Si solar module ranking #6,418 of 21,677 CEC listings (top 31.6%; higher than 68.4% of peers). It delivers 20.37% efficiency, 40.91 V Voc at 25 C, and 45.31 V cold Voc at -10 C (13 panels max per 600 V string).
- STC Wattage
- 440.0 W
- PTC Wattage
- 408.8 W
- Voc @ 25C
- 40.91 V
- Efficiency
- 20.37%
How Does Hyperion Solar HY-DH120P8-440 Compare Against Peer CEC Listings?
Solar engineering breakdown for Hyperion Solar HY-DH120P8-440: PTC thermal retention, roof footprint, and cold Voc string bounds. Regional housing vintage, storm hazard frequency, and wholesale utility prices directly govern residential upgrade payback across jurisdictions.
Measured at 440.0 W STC and 408.8 W PTC, Hyperion Solar HY-DH120P8-440 sits +55.0 W vs all-CEC median (top 31.6%; higher than 68.4% of peers) among 21,677 listed modules. Power density reaches 203.7 W/m2 (0.46 percentage points above 19.91% CEC median). Mid-range 40.91 V open-circuit voltage allows up to 13 panels per 600 V string at 14 F, whereas 1,000 V commercial inverters handle up to 22 panels in series. Alternative peer ALTERNATIVE ENERGY (AE) SOLAR CO LTD AE440MD-120BS rates 440.0 W.
Where Does Hyperion Solar HY-DH120P8-440 Fall Across Listed CEC Models?
Distribution marker showing Hyperion Solar HY-DH120P8-440 (440.0 W) relative to the 385.0 W all-CEC solar panel median. Homeowners and permit reviewers can filter tables below to benchmark specific ratings, wiring ages, and code allowances side by side.
What Dataset Percentiles Define Hyperion Solar HY-DH120P8-440?
Dataset percentiles tracking Hyperion Solar HY-DH120P8-440 power output, thermal retention ratio, and aperture efficiency against 21,677 models. Data intervals combine current 2025 federal utility and BLS wage releases with verified state electrical board rosters.
What Do the Dataset Ranks Show for Hyperion Solar HY-DH120P8-440?
Benchmark highlights for Hyperion Solar HY-DH120P8-440 covering STC output, efficiency, 8 kW footprint, and OCPD breaker size. Always verify current state NEC adoption cycles, local utility interconnection tariffs, and panel busbar ratings before pulling project permits.
Top 31.6% STC Output
440.0 W STC (+55.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.
20.37% Aperture Efficiency
Power density 203.7 W/m2 (0.46 percentage points above 19.91% CEC median). PTC/STC ratio: 92.9% (rank #10,348).
13 Panels Max @ -10 C (600 V)
Cold Voc reaches 45.31 V at -10 C (589.0 V string) and 46.56 V at -20 C (12 max).
19 Panels = 8,360 W STC
Occupies 41.0 m2 (442 sq ft) producing 7,767 W PTC; NEC 690.8 OCPD floor is 21.37 A (25 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 40.91 * (1 + (-0.307/100) * (-10 - 25)) = 45.31 V | OCPD = 1.56 * 13.7 = 21.37 A
Inputs from CEC Modules.csv for Hyperion Solar HY-DH120P8-440: Voc=40.91 V, beta_Voc=-0.307%/C, Isc=13.7 A, STC=440.0 W, Area=2.16 m2.
Result: 13 panels max on 600 V (589.0 V); 19 panels for 8 kW (442 sq ft).
What Are the Published CEC Specifications for Hyperion Solar HY-DH120P8-440?
Official CEC datasheet figures for Hyperion Solar HY-DH120P8-440 (Mono-c-Si) used in utility interconnection and permit reviews. Every reported metric links directly to federal public records or state regulatory filings with zero paid contractor placements.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 440.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 408.8 W (92.9% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 40.91 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 13.7 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 34.41 V / 12.79 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.307 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 20.37% (2.16 m2) | Array roof footprint density |
| Cell Count & Technology | 60 cells (Mono-c-Si) | Bifacial glass-glass |
How Many Hyperion Solar HY-DH120P8-440 Panels Build a 6 kW, 8 kW, or 10 kW Array?
How many Hyperion Solar HY-DH120P8-440 modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 14 | 6.16 kW | 326 sq ft | $1,542 | $2,607 |
| 8 kW Class | 19 | 8.36 kW | 442 sq ft | $2,092 | $3,538 |
| 10 kW Class | 23 | 10.12 kW | 535 sq ft | $2,533 | $4,283 |
Which Sibling Wattage & Trim Variants Belong to This Hyperion Solar Series?
Consolidated Hyperion Solar wattage variants sharing the Hyperion Solar HY-DH120P8-440 mechanical and cell layout. Use these verified dataset benchmarks alongside a licensed electrician load calculation to compare residential upgrade bids with confidence.
| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| Hyperion Solar HY-DH120P8-435 | 435.0 W | 404.0 W | 40.78 V | 34.26 V | 20.14% |
| Hyperion Solar HY-DH120P8-440 | 440.0 W | 408.8 W | 40.91 V | 34.41 V | 20.37% |
| Hyperion Solar HY-DH120P8-445 | 445.0 W | 413.5 W | 41.04 V | 34.58 V | 20.6% |
How Many Hyperion Solar HY-DH120P8-440 Modules Fit in a Cold-Weather String?
NEC 690.7(A) winter string table preventing overvoltage trips on Hyperion Solar HY-DH120P8-440 (45.31 V at 14 F).
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 46.56 V | 12 panels | 558.7 V | 21 panels |
| -10 C (14 F) | 45.31 V | 13 panels | 589.0 V | 22 panels |
| 0 C (32 F) | 44.05 V | 13 panels | 572.6 V | 22 panels |
| 25 C (77 F STC) | 40.91 V | 14 panels | 572.7 V | 24 panels |
Which Cross-Brand Solar Modules Compare Closest to Hyperion Solar HY-DH120P8-440?
Competing CEC solar panels closest to Hyperion Solar HY-DH120P8-440 in nameplate wattage and Voc, starting with ALTERNATIVE ENERGY (AE) SOLAR CO LTD AE440MD-120BS.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| ALTERNATIVE ENERGY (AE) SOLAR CO LTD AE440MD-120BS ALTERNATIVE ENERGY (AE) SOLAR CO LTD |
440.0 W | Tie (0 W) | 41.1 V | 20.56% | 92.6% |
| Aptos Solar Technology LLC DNA-120-BF10-440W Aptos Solar Technology LLC |
440.0 W | Tie (0 W) | 41.11 V | 20.56% | 92.6% |
| Dehui Solar Power (Vietnam) CoLtd DH-M160T 440W Dehui Solar Power (Vietnam) CoLtd |
440.0 W | Tie (0 W) | 41.11 V | 20.56% | 92.6% |
| Aptos Solar Technology LLC DNA-120-BF10-440W-USAptos1 Aptos Solar Technology LLC |
440.0 W | Tie (0 W) | 41.18 V | 20.56% | 94.3% |
What Are the Design Limits and Best-Fit Uses for Hyperion Solar HY-DH120P8-440?
Evaluate Hyperion Solar HY-DH120P8-440 (440.0 W STC, 40.91 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), Hyperion Solar HY-DH120P8-440 reaches 46.56 V per panel—exceeding 12 panels in series voids 600 V inverter warranties.
- Footprint constraint: 19 panels for an 8 kW build require 442 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 19 panels (442 sq ft) for an 8 kW array.
- 2026 tax credit baseline: cash residential installs of Hyperion Solar HY-DH120P8-440 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
Hyperion Solar HY-DH120P8-440 8 kW Residential Fit
Needs 19 modules (442 sq ft) with a 25 A string OCPD, offsetting ~$2,092/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 13 panels (-10 C) or 12 panels (-20 C), or compare ALTERNATIVE ENERGY (AE) SOLAR CO LTD AE440MD-120BS.
Bifacial / High-Heat Roof Check
Glass-glass bifacial cells capture rear albedo reflection over light ground gravel or white membranes. Real-world output tracks 408.8 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for Hyperion Solar HY-DH120P8-440 by Hyperion Solar grounded in CEC test data and NEC 690.7/690.8 limits.
How many Hyperion Solar HY-DH120P8-440 panels fit on a 600 V winter solar string?
At -10 C (14 F), Hyperion Solar HY-DH120P8-440 cold Voc rises from 40.91 V to 45.31 V (beta_Voc -0.307%/C), capping a 600 V string at 13 panels (589.0 V).
How much roof area does an 8 kW array of Hyperion Solar HY-DH120P8-440 need?
An 8 kW DC system uses 19 Hyperion Solar HY-DH120P8-440 modules (8,360 W STC / 7,767 W PTC), covering roughly 442 sq ft and saving ~$2,092/yr at 18.54 c/kWh.
How does Hyperion Solar HY-DH120P8-440 compare against ALTERNATIVE ENERGY (AE) SOLAR CO LTD AE440MD-120BS?
Hyperion Solar HY-DH120P8-440 outputs 440.0 W STC (40.91 V Voc, rank #6,418 of 21,677), while ALTERNATIVE ENERGY (AE) SOLAR CO LTD AE440MD-120BS delivers 440.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)