Skip to main content
WireAndSun
Calculators
CEC PV Module

Hyperion Solar HY-DH120P8-440-T — CEC Solar Module Specifications

Manufacturer: Hyperion Solar Registry: CEC Verified Engineering Specification

Hyperion Solar HY-DH120P8-440-T is a 440.0 W STC (408.8 W PTC) Mono-c-Si solar module ranking #6,418 of 21,677 CEC listings (top 31.6%; higher than 68.4% of peers). It delivers 20.37% efficiency, 40.91 V Voc at 25 C, and 45.31 V cold Voc at -10 C (13 panels max per 600 V string).

STC Wattage
440.0 W
PTC Wattage
408.8 W
Voc @ 25C
40.91 V
Efficiency
20.37%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does Hyperion Solar HY-DH120P8-440-T Compare Against Peer CEC Listings?

Engineering position of Hyperion Solar HY-DH120P8-440-T (440.0 W STC) vs. ALTERNATIVE ENERGY (AE) SOLAR CO LTD AE440MD-120BS across 5,889 CEC Mono-c-Si solar modules.

Built with 60 Mono-c-Si cells, Hyperion Solar HY-DH120P8-440-T pairs strong 92.9% PTC-to-STC heat retention (#10,348 of 21,677) with 40.91 V nominal Voc. An 8 kW residential build (8,360 W DC, 7,767 W PTC) saves ~$2,092/yr at 18.54 c/kWh with zero federal 25D credit in 2026. Glass-glass bifacial cells capture rear albedo reflection over light ground gravel or white membranes. Peer ALTERNATIVE ENERGY (AE) SOLAR CO LTD AE440MD-120BS offers a 440.0 W alternative.

Where Does Hyperion Solar HY-DH120P8-440-T Fall Across Listed CEC Models?

Plots Hyperion Solar HY-DH120P8-440-T at 440.0 W STC across all 21,677 California Energy Commission photovoltaic modules relative to the 385.0 W median.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where Hyperion Solar HY-DH120P8-440-T (440.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCHyperion Solar HY-: 440.0 W

What Dataset Percentiles Define Hyperion Solar HY-DH120P8-440-T?

Benchmarks Hyperion Solar HY-DH120P8-440-T on STC wattage, thermal PTC/STC retention, and 20.37 aperture conversion efficiency against CEC peers.

Hyperion Solar HY-DH120P8-440-T Engineering BenchmarksPercentile comparison of Hyperion Solar HY-DH120P8-440-T wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage440.0 WPTC/STC Retention92.9%Module Efficiency20.37%

What Do the Dataset Ranks Show for Hyperion Solar HY-DH120P8-440-T?

Key electrical performance ranks, roof area sizing, and NEC 690.7/690.8 design boundaries for Hyperion Solar HY-DH120P8-440-T by Hyperion Solar.

Rank #6,418 / 21,677

Top 31.6% STC Output

440.0 W STC (+55.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #9,017

20.37% Aperture Efficiency

Power density 203.7 W/m2 (0.46 percentage points above 19.91% CEC median). PTC/STC ratio: 92.9% (rank #10,348).

NEC 690.7 Limit

13 Panels Max @ -10 C (600 V)

Cold Voc reaches 45.31 V at -10 C (589.0 V string) and 46.56 V at -20 C (12 max).

8 kW Reference Array

19 Panels = 8,360 W STC

Occupies 41.0 m2 (442 sq ft) producing 7,767 W PTC; NEC 690.8 OCPD floor is 21.37 A (25 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 40.91 * (1 + (-0.307/100) * (-10 - 25)) = 45.31 V | OCPD = 1.56 * 13.7 = 21.37 A

Inputs from CEC Modules.csv for Hyperion Solar HY-DH120P8-440-T: Voc=40.91 V, beta_Voc=-0.307%/C, Isc=13.7 A, STC=440.0 W, Area=2.16 m2.

Result: 13 panels max on 600 V (589.0 V); 19 panels for 8 kW (442 sq ft).

What Are the Published CEC Specifications for Hyperion Solar HY-DH120P8-440-T?

Laboratory test ratings recorded for Hyperion Solar HY-DH120P8-440-T (Mono-c-Si) in the official California Energy Commission NREL SAM equipment catalog.

Official California Energy Commission (NREL SAM) test parameters for Hyperion Solar HY-DH120P8-440-T.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 440.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 408.8 W (92.9% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 40.91 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 13.7 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 34.41 V / 12.79 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.307 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 20.37% (2.16 m2) Array roof footprint density
Cell Count & Technology 60 cells (Mono-c-Si) Bifacial glass-glass

How Many Hyperion Solar HY-DH120P8-440-T Panels Build a 6 kW, 8 kW, or 10 kW Array?

Panel counts, roof square footage (442 sq ft at 8 kW), and estimated Year-1 electric bill offset for Hyperion Solar HY-DH120P8-440-T.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 14 6.16 kW 326 sq ft $1,542 $2,607
8 kW Class 19 8.36 kW 442 sq ft $2,092 $3,538
10 kW Class 23 10.12 kW 535 sq ft $2,533 $4,283

Which Sibling Wattage & Trim Variants Belong to This Hyperion Solar Series?

Sibling wattage bins and frame colors grouped with Hyperion Solar HY-DH120P8-440-T under Hyperion Solar to prevent duplicate spec pages.

Sibling CEC listings grouped into the Hyperion Solar HY-DH120P8-440-T wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
Hyperion Solar HY-DH120P8-435-T 435.0 W 404.0 W 40.78 V 34.26 V 20.14%
Hyperion Solar HY-DH120P8-440-T 440.0 W 408.8 W 40.91 V 34.41 V 20.37%
Hyperion Solar HY-DH120P8-445-T 445.0 W 413.5 W 41.04 V 34.58 V 20.6%

How Many Hyperion Solar HY-DH120P8-440-T Modules Fit in a Cold-Weather String?

Cold-weather Voc escalation for Hyperion Solar HY-DH120P8-440-T (beta_Voc -0.307%/C) across 600 V residential and 1,000 V commercial inverters.

Computed from Voc=40.91V and beta_Voc=-0.307%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 46.56 V 12 panels 558.7 V 21 panels
-10 C (14 F) 45.31 V 13 panels 589.0 V 22 panels
0 C (32 F) 44.05 V 13 panels 572.6 V 22 panels
25 C (77 F STC) 40.91 V 14 panels 572.7 V 24 panels

Which Cross-Brand Solar Modules Compare Closest to Hyperion Solar HY-DH120P8-440-T?

Closest cross-brand CEC competitors to Hyperion Solar HY-DH120P8-440-T matched near 440.0 W STC and 40.91 V Voc, led by ALTERNATIVE ENERGY (AE) SOLAR CO LTD AE440MD-120BS.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
ALTERNATIVE ENERGY (AE) SOLAR CO LTD AE440MD-120BS
ALTERNATIVE ENERGY (AE) SOLAR CO LTD
440.0 W Tie (0 W) 41.1 V 20.56% 92.6%
Aptos Solar Technology LLC DNA-120-BF10-440W
Aptos Solar Technology LLC
440.0 W Tie (0 W) 41.11 V 20.56% 92.6%
Dehui Solar Power (Vietnam) CoLtd DH-M160T 440W
Dehui Solar Power (Vietnam) CoLtd
440.0 W Tie (0 W) 41.11 V 20.56% 92.6%
Aptos Solar Technology LLC DNA-120-BF10-440W-USAptos1
Aptos Solar Technology LLC
440.0 W Tie (0 W) 41.18 V 20.56% 94.3%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for Hyperion Solar HY-DH120P8-440-T?

Evaluate Hyperion Solar HY-DH120P8-440-T (440.0 W STC, 40.91 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), Hyperion Solar HY-DH120P8-440-T reaches 46.56 V per panel—exceeding 12 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 19 panels for an 8 kW build require 442 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 19 panels (442 sq ft) for an 8 kW array.
  • 2026 tax credit baseline: cash residential installs of Hyperion Solar HY-DH120P8-440-T carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

Hyperion Solar HY-DH120P8-440-T 8 kW Residential Fit

Needs 19 modules (442 sq ft) with a 25 A string OCPD, offsetting ~$2,092/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 13 panels (-10 C) or 12 panels (-20 C), or compare ALTERNATIVE ENERGY (AE) SOLAR CO LTD AE440MD-120BS.

Bifacial / High-Heat Roof Check

Glass-glass bifacial cells capture rear albedo reflection over light ground gravel or white membranes. Real-world output tracks 408.8 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Hyperion Solar HY-DH120P8-440-T by Hyperion Solar grounded in CEC test data and NEC 690.7/690.8 limits.

What fuse or breaker size does NEC 690.8 require for Hyperion Solar HY-DH120P8-440-T?

Multiplying Hyperion Solar HY-DH120P8-440-T's 13.7 A short-circuit current by 1.56 equals 21.37 A minimum ampacity, requiring at least a 25 A overcurrent fuse or breaker.

Can Hyperion Solar HY-DH120P8-440-T pair with microinverters instead of a 600 V string inverter?

Yes—if the microinverter DC input ceiling exceeds 45.31 V cold Voc at 14 F and handles 13.7 A Isc; string inverters cap Hyperion Solar HY-DH120P8-440-T at 13 panels on 600 V.

Is Hyperion Solar HY-DH120P8-440-T eligible for the 30% federal 25D solar credit in 2026?

No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of Hyperion Solar HY-DH120P8-440-T rely on utility bill offset (~$2,092/yr at 8 kW) rather than 25D.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.