Hyperion Solar HY-DH108P8-410 is a 410.0 W STC (381.2 W PTC) Mono-c-Si solar module ranking #8,539 of 21,677 CEC listings (top 41.3%; higher than 58.7% of peers). It delivers 21.03% efficiency, 37.32 V Voc at 25 C, and 41.33 V cold Voc at -10 C (14 panels max per 600 V string).
- STC Wattage
- 410.0 W
- PTC Wattage
- 381.2 W
- Voc @ 25C
- 37.32 V
- Efficiency
- 21.03%
How Does Hyperion Solar HY-DH108P8-410 Compare Against Peer CEC Listings?
CEC rank, roof space requirements, and NEC 690.7/690.8 limits for Hyperion Solar HY-DH108P8-410 (Mono-c-Si) residential solar systems.
Hyperion Solar HY-DH108P8-410 delivers 210.3 W/m2 (1.12 percentage points above 19.91% CEC median) and strong 93.0% PTC-to-STC heat retention (#9,879 of 21,677), placing it as a modern high-density residential and light-commercial module well-proportioned for residential pitched roofs needing 20 panels (420 sq ft) for an 8 kW array. At -4 F (-20 C), string voltage climbs to 42.48 V per unit, capping 600 V circuits at 14 panels. Compare specs directly with Elin Energy (Sirius PV) ELNSM54M-HC-BF-410 (410.0 W).
Where Does Hyperion Solar HY-DH108P8-410 Fall Across Listed CEC Models?
Comparison of Hyperion Solar HY-DH108P8-410 (410.0 W STC) against all 21,677 California Energy Commission certified photovoltaic modules. Review related calculators, peer benchmarks, and source citations below to validate design assumptions for your electrical service.
What Dataset Percentiles Define Hyperion Solar HY-DH108P8-410?
Relative ranking of Hyperion Solar HY-DH108P8-410 across nameplate watts, 93.0% PTC thermal ratio, and module aperture efficiency. Homeowners and permit reviewers can filter tables below to benchmark specific ratings, wiring ages, and code allowances side by side.
What Do the Dataset Ranks Show for Hyperion Solar HY-DH108P8-410?
Summary of Hyperion Solar HY-DH108P8-410 output rank, 8 kW array size (20 panels), efficiency rating, and 600 V string limit.
Top 41.3% STC Output
410.0 W STC (+25.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.
21.03% Aperture Efficiency
Power density 210.3 W/m2 (1.12 percentage points above 19.91% CEC median). PTC/STC ratio: 93.0% (rank #9,879).
14 Panels Max @ -10 C (600 V)
Cold Voc reaches 41.33 V at -10 C (578.6 V string) and 42.48 V at -20 C (14 max).
20 Panels = 8,200 W STC
Occupies 39.0 m2 (420 sq ft) producing 7,624 W PTC; NEC 690.8 OCPD floor is 21.76 A (25 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 37.32 * (1 + (-0.307/100) * (-10 - 25)) = 41.33 V | OCPD = 1.56 * 13.95 = 21.76 A
Inputs from CEC Modules.csv for Hyperion Solar HY-DH108P8-410: Voc=37.32 V, beta_Voc=-0.307%/C, Isc=13.95 A, STC=410.0 W, Area=1.95 m2.
Result: 14 panels max on 600 V (578.6 V); 20 panels for 8 kW (420 sq ft).
What Are the Published CEC Specifications for Hyperion Solar HY-DH108P8-410?
Complete CEC test sheet for Hyperion Solar HY-DH108P8-410 including Isc (13.95 A), Voc (37.32 V), and thermal temperature coefficients.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 410.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 381.2 W (93.0% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 37.32 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 13.95 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 31.45 V / 13.04 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.307 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 21.03% (1.95 m2) | Array roof footprint density |
| Cell Count & Technology | 54 cells (Mono-c-Si) | Bifacial glass-glass |
How Many Hyperion Solar HY-DH108P8-410 Panels Build a 6 kW, 8 kW, or 10 kW Array?
Residential array count and annual electric bill savings at 18.54 c/kWh US avg vs. California tariffs using Hyperion Solar HY-DH108P8-410.
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 15 | 6.15 kW | 315 sq ft | $1,539 | $2,603 |
| 8 kW Class | 20 | 8.2 kW | 420 sq ft | $2,052 | $3,470 |
| 10 kW Class | 25 | 10.25 kW | 525 sq ft | $2,565 | $4,338 |
Which Sibling Wattage & Trim Variants Belong to This Hyperion Solar Series?
Related Hyperion Solar power steps and black/silver trims consolidated into this Hyperion Solar HY-DH108P8-410 series guide. Cross-check local Authority Having Jurisdiction amendments and serving utility net-metering terms before finalizing project sizing.
| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| Hyperion Solar HY-DH108P8-400 | 400.0 W | 371.7 W | 37.07 V | 31.01 V | 20.51% |
| Hyperion Solar HY-DH108P8-405 | 405.0 W | 376.5 W | 37.23 V | 31.21 V | 20.77% |
| Hyperion Solar HY-DH108P8-410 | 410.0 W | 381.2 W | 37.32 V | 31.45 V | 21.03% |
| Hyperion Solar HY-DH108P8-415 | 415.0 W | 386.0 W | 37.45 V | 31.61 V | 21.28% |
How Many Hyperion Solar HY-DH108P8-410 Modules Fit in a Cold-Weather String?
Verify freezing-morning voltage rise for Hyperion Solar HY-DH108P8-410 (37.32 V STC) before wiring 600 V or 1,000 V strings.
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 42.48 V | 14 panels | 594.7 V | 23 panels |
| -10 C (14 F) | 41.33 V | 14 panels | 578.6 V | 24 panels |
| 0 C (32 F) | 40.18 V | 14 panels | 562.5 V | 24 panels |
| 25 C (77 F STC) | 37.32 V | 16 panels | 597.1 V | 26 panels |
Which Cross-Brand Solar Modules Compare Closest to Hyperion Solar HY-DH108P8-410?
Four comparable CEC modules such as Elin Energy (Sirius PV) ELNSM54M-HC-BF-410 (410.0 W) for side-by-side solar quote checks.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| Elin Energy (Sirius PV) ELNSM54M-HC-BF-410 Elin Energy (Sirius PV) |
410.0 W | Tie (0 W) | 37.32 V | 21.13% | 94.4% |
| ASTORIOS Holding Inc ASTR108BDG-410W-US ASTORIOS Holding Inc |
410.0 W | Tie (0 W) | 37.5 V | 21.13% | 93.0% |
| AXITEC AC-410MBT/108US AXITEC |
410.0 W | Tie (0 W) | 37.5 V | 21.13% | 93.0% |
| CSI Solar Co Ltd CS6R-410MB CSI Solar Co Ltd |
410.0 W | Tie (0 W) | 38.0 V | 21.69% | 94.2% |
What Are the Design Limits and Best-Fit Uses for Hyperion Solar HY-DH108P8-410?
Evaluate Hyperion Solar HY-DH108P8-410 (410.0 W STC, 37.32 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), Hyperion Solar HY-DH108P8-410 reaches 42.48 V per panel—exceeding 14 panels in series voids 600 V inverter warranties.
- Footprint constraint: 20 panels for an 8 kW build require 420 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 20 panels (420 sq ft) for an 8 kW array.
- 2026 tax credit baseline: cash residential installs of Hyperion Solar HY-DH108P8-410 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
Hyperion Solar HY-DH108P8-410 8 kW Residential Fit
Needs 20 modules (420 sq ft) with a 25 A string OCPD, offsetting ~$2,052/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 14 panels (-10 C) or 14 panels (-20 C), or compare Elin Energy (Sirius PV) ELNSM54M-HC-BF-410.
Bifacial / High-Heat Roof Check
Glass-glass bifacial cells capture rear albedo reflection over light ground gravel or white membranes. Real-world output tracks 381.2 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for Hyperion Solar HY-DH108P8-410 by Hyperion Solar grounded in CEC test data and NEC 690.7/690.8 limits.
How many Hyperion Solar HY-DH108P8-410 panels fit on a 600 V winter solar string?
At -10 C (14 F), Hyperion Solar HY-DH108P8-410 cold Voc rises from 37.32 V to 41.33 V (beta_Voc -0.307%/C), capping a 600 V string at 14 panels (578.6 V).
How much roof area does an 8 kW array of Hyperion Solar HY-DH108P8-410 need?
An 8 kW DC system uses 20 Hyperion Solar HY-DH108P8-410 modules (8,200 W STC / 7,624 W PTC), covering roughly 420 sq ft and saving ~$2,052/yr at 18.54 c/kWh.
How does Hyperion Solar HY-DH108P8-410 compare against Elin Energy (Sirius PV) ELNSM54M-HC-BF-410?
Hyperion Solar HY-DH108P8-410 outputs 410.0 W STC (37.32 V Voc, rank #8,539 of 21,677), while Elin Energy (Sirius PV) ELNSM54M-HC-BF-410 delivers 410.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)