Manufacturer: Hyperion Solar Registry: CEC Verified Engineering Specification

Hyperion Solar HY-DH108P8-410 is a 410.0 W STC (381.2 W PTC) Mono-c-Si solar module ranking #8,539 of 21,677 CEC listings (top 41.3%; higher than 58.7% of peers). It delivers 21.03% efficiency, 37.32 V Voc at 25 C, and 41.33 V cold Voc at -10 C (14 panels max per 600 V string).

STC Wattage
410.0 W
PTC Wattage
381.2 W
Voc @ 25C
37.32 V
Efficiency
21.03%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does Hyperion Solar HY-DH108P8-410 Compare Against Peer CEC Listings?

CEC rank, roof space requirements, and NEC 690.7/690.8 limits for Hyperion Solar HY-DH108P8-410 (Mono-c-Si) residential solar systems.

Hyperion Solar HY-DH108P8-410 delivers 210.3 W/m2 (1.12 percentage points above 19.91% CEC median) and strong 93.0% PTC-to-STC heat retention (#9,879 of 21,677), placing it as a modern high-density residential and light-commercial module well-proportioned for residential pitched roofs needing 20 panels (420 sq ft) for an 8 kW array. At -4 F (-20 C), string voltage climbs to 42.48 V per unit, capping 600 V circuits at 14 panels. Compare specs directly with Elin Energy (Sirius PV) ELNSM54M-HC-BF-410 (410.0 W).

Where Does Hyperion Solar HY-DH108P8-410 Fall Across Listed CEC Models?

Comparison of Hyperion Solar HY-DH108P8-410 (410.0 W STC) against all 21,677 California Energy Commission certified photovoltaic modules. Review related calculators, peer benchmarks, and source citations below to validate design assumptions for your electrical service.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where Hyperion Solar HY-DH108P8-410 (410.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCHyperion Solar HY-: 410.0 W

What Dataset Percentiles Define Hyperion Solar HY-DH108P8-410?

Relative ranking of Hyperion Solar HY-DH108P8-410 across nameplate watts, 93.0% PTC thermal ratio, and module aperture efficiency. Homeowners and permit reviewers can filter tables below to benchmark specific ratings, wiring ages, and code allowances side by side.

Hyperion Solar HY-DH108P8-410 Engineering BenchmarksPercentile comparison of Hyperion Solar HY-DH108P8-410 wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage410.0 WPTC/STC Retention93.0%Module Efficiency21.03%

What Do the Dataset Ranks Show for Hyperion Solar HY-DH108P8-410?

Summary of Hyperion Solar HY-DH108P8-410 output rank, 8 kW array size (20 panels), efficiency rating, and 600 V string limit.

Rank #8,539 / 21,677

Top 41.3% STC Output

410.0 W STC (+25.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #6,235

21.03% Aperture Efficiency

Power density 210.3 W/m2 (1.12 percentage points above 19.91% CEC median). PTC/STC ratio: 93.0% (rank #9,879).

NEC 690.7 Limit

14 Panels Max @ -10 C (600 V)

Cold Voc reaches 41.33 V at -10 C (578.6 V string) and 42.48 V at -20 C (14 max).

8 kW Reference Array

20 Panels = 8,200 W STC

Occupies 39.0 m2 (420 sq ft) producing 7,624 W PTC; NEC 690.8 OCPD floor is 21.76 A (25 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 37.32 * (1 + (-0.307/100) * (-10 - 25)) = 41.33 V | OCPD = 1.56 * 13.95 = 21.76 A

Inputs from CEC Modules.csv for Hyperion Solar HY-DH108P8-410: Voc=37.32 V, beta_Voc=-0.307%/C, Isc=13.95 A, STC=410.0 W, Area=1.95 m2.

Result: 14 panels max on 600 V (578.6 V); 20 panels for 8 kW (420 sq ft).

What Are the Published CEC Specifications for Hyperion Solar HY-DH108P8-410?

Complete CEC test sheet for Hyperion Solar HY-DH108P8-410 including Isc (13.95 A), Voc (37.32 V), and thermal temperature coefficients.

Official California Energy Commission (NREL SAM) test parameters for Hyperion Solar HY-DH108P8-410.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 410.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 381.2 W (93.0% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 37.32 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 13.95 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 31.45 V / 13.04 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.307 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 21.03% (1.95 m2) Array roof footprint density
Cell Count & Technology 54 cells (Mono-c-Si) Bifacial glass-glass

How Many Hyperion Solar HY-DH108P8-410 Panels Build a 6 kW, 8 kW, or 10 kW Array?

Residential array count and annual electric bill savings at 18.54 c/kWh US avg vs. California tariffs using Hyperion Solar HY-DH108P8-410.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 15 6.15 kW 315 sq ft $1,539 $2,603
8 kW Class 20 8.2 kW 420 sq ft $2,052 $3,470
10 kW Class 25 10.25 kW 525 sq ft $2,565 $4,338

Which Sibling Wattage & Trim Variants Belong to This Hyperion Solar Series?

Related Hyperion Solar power steps and black/silver trims consolidated into this Hyperion Solar HY-DH108P8-410 series guide. Cross-check local Authority Having Jurisdiction amendments and serving utility net-metering terms before finalizing project sizing.

Sibling CEC listings grouped into the Hyperion Solar HY-DH108P8-410 wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
Hyperion Solar HY-DH108P8-400 400.0 W 371.7 W 37.07 V 31.01 V 20.51%
Hyperion Solar HY-DH108P8-405 405.0 W 376.5 W 37.23 V 31.21 V 20.77%
Hyperion Solar HY-DH108P8-410 410.0 W 381.2 W 37.32 V 31.45 V 21.03%
Hyperion Solar HY-DH108P8-415 415.0 W 386.0 W 37.45 V 31.61 V 21.28%

How Many Hyperion Solar HY-DH108P8-410 Modules Fit in a Cold-Weather String?

Verify freezing-morning voltage rise for Hyperion Solar HY-DH108P8-410 (37.32 V STC) before wiring 600 V or 1,000 V strings.

Computed from Voc=37.32V and beta_Voc=-0.307%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 42.48 V 14 panels 594.7 V 23 panels
-10 C (14 F) 41.33 V 14 panels 578.6 V 24 panels
0 C (32 F) 40.18 V 14 panels 562.5 V 24 panels
25 C (77 F STC) 37.32 V 16 panels 597.1 V 26 panels

Which Cross-Brand Solar Modules Compare Closest to Hyperion Solar HY-DH108P8-410?

Four comparable CEC modules such as Elin Energy (Sirius PV) ELNSM54M-HC-BF-410 (410.0 W) for side-by-side solar quote checks.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
Elin Energy (Sirius PV) ELNSM54M-HC-BF-410
Elin Energy (Sirius PV)
410.0 W Tie (0 W) 37.32 V 21.13% 94.4%
ASTORIOS Holding Inc ASTR108BDG-410W-US
ASTORIOS Holding Inc
410.0 W Tie (0 W) 37.5 V 21.13% 93.0%
AXITEC AC-410MBT/108US
AXITEC
410.0 W Tie (0 W) 37.5 V 21.13% 93.0%
CSI Solar Co Ltd CS6R-410MB
CSI Solar Co Ltd
410.0 W Tie (0 W) 38.0 V 21.69% 94.2%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for Hyperion Solar HY-DH108P8-410?

Evaluate Hyperion Solar HY-DH108P8-410 (410.0 W STC, 37.32 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), Hyperion Solar HY-DH108P8-410 reaches 42.48 V per panel—exceeding 14 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 20 panels for an 8 kW build require 420 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 20 panels (420 sq ft) for an 8 kW array.
  • 2026 tax credit baseline: cash residential installs of Hyperion Solar HY-DH108P8-410 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

Hyperion Solar HY-DH108P8-410 8 kW Residential Fit

Needs 20 modules (420 sq ft) with a 25 A string OCPD, offsetting ~$2,052/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 14 panels (-10 C) or 14 panels (-20 C), or compare Elin Energy (Sirius PV) ELNSM54M-HC-BF-410.

Bifacial / High-Heat Roof Check

Glass-glass bifacial cells capture rear albedo reflection over light ground gravel or white membranes. Real-world output tracks 381.2 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Hyperion Solar HY-DH108P8-410 by Hyperion Solar grounded in CEC test data and NEC 690.7/690.8 limits.

How many Hyperion Solar HY-DH108P8-410 panels fit on a 600 V winter solar string?

At -10 C (14 F), Hyperion Solar HY-DH108P8-410 cold Voc rises from 37.32 V to 41.33 V (beta_Voc -0.307%/C), capping a 600 V string at 14 panels (578.6 V).

How much roof area does an 8 kW array of Hyperion Solar HY-DH108P8-410 need?

An 8 kW DC system uses 20 Hyperion Solar HY-DH108P8-410 modules (8,200 W STC / 7,624 W PTC), covering roughly 420 sq ft and saving ~$2,052/yr at 18.54 c/kWh.

How does Hyperion Solar HY-DH108P8-410 compare against Elin Energy (Sirius PV) ELNSM54M-HC-BF-410?

Hyperion Solar HY-DH108P8-410 outputs 410.0 W STC (37.32 V Voc, rank #8,539 of 21,677), while Elin Energy (Sirius PV) ELNSM54M-HC-BF-410 delivers 410.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes