Manufacturer: Hyperion Solar Registry: CEC Verified Engineering Specification

Hyperion Solar HY-DH108P8-410-T is a 410.0 W STC (381.2 W PTC) Mono-c-Si solar module ranking #8,539 of 21,677 CEC listings (top 41.3%; higher than 58.7% of peers). It delivers 21.03% efficiency, 37.32 V Voc at 25 C, and 41.33 V cold Voc at -10 C (14 panels max per 600 V string).

STC Wattage
410.0 W
PTC Wattage
381.2 W
Voc @ 25C
37.32 V
Efficiency
21.03%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does Hyperion Solar HY-DH108P8-410-T Compare Against Peer CEC Listings?

Solar engineering breakdown for Hyperion Solar HY-DH108P8-410-T: PTC thermal retention, roof footprint, and cold Voc string bounds. Inspect manufacturer nameplate documentation, UL listing boundaries, and utility rate schedules closely before ordering electrical hardware.

Across 5,889 Mono-c-Si listings from Hyperion Solar and peers, Hyperion Solar HY-DH108P8-410-T stands equal to the 410.0 W Mono-c-Si median and strong 93.0% PTC-to-STC heat retention (#9,879 of 21,677). Sizing 6 kW (15 panels) to 10 kW (25 panels) yields $1,539-$2,565/yr in baseline US bill offset. Lower 37.32 V string voltage fits 14 panels in series at 14 F and pairs easily with microinverters.

Where Does Hyperion Solar HY-DH108P8-410-T Fall Across Listed CEC Models?

Distribution marker showing Hyperion Solar HY-DH108P8-410-T (410.0 W) relative to the 385.0 W all-CEC solar panel median. Always verify current state NEC adoption cycles, local utility interconnection tariffs, and panel busbar ratings before pulling project permits.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where Hyperion Solar HY-DH108P8-410-T (410.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCHyperion Solar HY-: 410.0 W

What Dataset Percentiles Define Hyperion Solar HY-DH108P8-410-T?

Dataset percentiles tracking Hyperion Solar HY-DH108P8-410-T power output, thermal retention ratio, and aperture efficiency against 21,677 models. Compare thermal ratings, overcurrent protection caps, and continuous load headroom carefully before expanding an existing home service panel.

Hyperion Solar HY-DH108P8-410-T Engineering BenchmarksPercentile comparison of Hyperion Solar HY-DH108P8-410-T wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage410.0 WPTC/STC Retention93.0%Module Efficiency21.03%

What Do the Dataset Ranks Show for Hyperion Solar HY-DH108P8-410-T?

Benchmark highlights for Hyperion Solar HY-DH108P8-410-T covering STC output, efficiency, 8 kW footprint, and OCPD breaker size. Review related calculators, peer benchmarks, and source citations below to validate design assumptions for your electrical service.

Rank #8,539 / 21,677

Top 41.3% STC Output

410.0 W STC (+25.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #6,235

21.03% Aperture Efficiency

Power density 210.3 W/m2 (1.12 percentage points above 19.91% CEC median). PTC/STC ratio: 93.0% (rank #9,879).

NEC 690.7 Limit

14 Panels Max @ -10 C (600 V)

Cold Voc reaches 41.33 V at -10 C (578.6 V string) and 42.48 V at -20 C (14 max).

8 kW Reference Array

20 Panels = 8,200 W STC

Occupies 39.0 m2 (420 sq ft) producing 7,624 W PTC; NEC 690.8 OCPD floor is 21.76 A (25 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 37.32 * (1 + (-0.307/100) * (-10 - 25)) = 41.33 V | OCPD = 1.56 * 13.95 = 21.76 A

Inputs from CEC Modules.csv for Hyperion Solar HY-DH108P8-410-T: Voc=37.32 V, beta_Voc=-0.307%/C, Isc=13.95 A, STC=410.0 W, Area=1.95 m2.

Result: 14 panels max on 600 V (578.6 V); 20 panels for 8 kW (420 sq ft).

What Are the Published CEC Specifications for Hyperion Solar HY-DH108P8-410-T?

Official CEC datasheet figures for Hyperion Solar HY-DH108P8-410-T (Mono-c-Si) used in utility interconnection and permit reviews. Use these verified dataset benchmarks alongside a licensed electrician load calculation to compare residential upgrade bids with confidence.

Official California Energy Commission (NREL SAM) test parameters for Hyperion Solar HY-DH108P8-410-T.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 410.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 381.2 W (93.0% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 37.32 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 13.95 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 31.45 V / 13.04 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.307 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 21.03% (1.95 m2) Array roof footprint density
Cell Count & Technology 54 cells (Mono-c-Si) Bifacial glass-glass

How Many Hyperion Solar HY-DH108P8-410-T Panels Build a 6 kW, 8 kW, or 10 kW Array?

How many Hyperion Solar HY-DH108P8-410-T modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 15 6.15 kW 315 sq ft $1,539 $2,603
8 kW Class 20 8.2 kW 420 sq ft $2,052 $3,470
10 kW Class 25 10.25 kW 525 sq ft $2,565 $4,338

Which Sibling Wattage & Trim Variants Belong to This Hyperion Solar Series?

Consolidated Hyperion Solar wattage variants sharing the Hyperion Solar HY-DH108P8-410-T mechanical and cell layout. All figures trace directly to published federal energy filings, state electrical boards, CEC datasheets, and NFPA 70 NEC tables.

Sibling CEC listings grouped into the Hyperion Solar HY-DH108P8-410-T wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
Hyperion Solar HY-DH108P8-400-T 400.0 W 371.7 W 37.07 V 31.01 V 20.51%
Hyperion Solar HY-DH108P8-405-T 405.0 W 376.5 W 37.23 V 31.21 V 20.77%
Hyperion Solar HY-DH108P8-410-T 410.0 W 381.2 W 37.32 V 31.45 V 21.03%
Hyperion Solar HY-DH108P8-415-T 415.0 W 386.0 W 37.45 V 31.61 V 21.28%

How Many Hyperion Solar HY-DH108P8-410-T Modules Fit in a Cold-Weather String?

NEC 690.7(A) winter string table preventing overvoltage trips on Hyperion Solar HY-DH108P8-410-T (41.33 V at 14 F).

Computed from Voc=37.32V and beta_Voc=-0.307%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 42.48 V 14 panels 594.7 V 23 panels
-10 C (14 F) 41.33 V 14 panels 578.6 V 24 panels
0 C (32 F) 40.18 V 14 panels 562.5 V 24 panels
25 C (77 F STC) 37.32 V 16 panels 597.1 V 26 panels

Which Cross-Brand Solar Modules Compare Closest to Hyperion Solar HY-DH108P8-410-T?

Competing CEC solar panels closest to Hyperion Solar HY-DH108P8-410-T in nameplate wattage and Voc, starting with Elin Energy (Sirius PV) ELNSM54M-HC-BF-410.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
Elin Energy (Sirius PV) ELNSM54M-HC-BF-410
Elin Energy (Sirius PV)
410.0 W Tie (0 W) 37.32 V 21.13% 94.4%
ASTORIOS Holding Inc ASTR108BDG-410W-US
ASTORIOS Holding Inc
410.0 W Tie (0 W) 37.5 V 21.13% 93.0%
AXITEC AC-410MBT/108US
AXITEC
410.0 W Tie (0 W) 37.5 V 21.13% 93.0%
CSI Solar Co Ltd CS6R-410MB
CSI Solar Co Ltd
410.0 W Tie (0 W) 38.0 V 21.69% 94.2%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for Hyperion Solar HY-DH108P8-410-T?

Evaluate Hyperion Solar HY-DH108P8-410-T (410.0 W STC, 37.32 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), Hyperion Solar HY-DH108P8-410-T reaches 42.48 V per panel—exceeding 14 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 20 panels for an 8 kW build require 420 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 20 panels (420 sq ft) for an 8 kW array.
  • 2026 tax credit baseline: cash residential installs of Hyperion Solar HY-DH108P8-410-T carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

Hyperion Solar HY-DH108P8-410-T 8 kW Residential Fit

Needs 20 modules (420 sq ft) with a 25 A string OCPD, offsetting ~$2,052/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 14 panels (-10 C) or 14 panels (-20 C), or compare Elin Energy (Sirius PV) ELNSM54M-HC-BF-410.

Bifacial / High-Heat Roof Check

Glass-glass bifacial cells capture rear albedo reflection over light ground gravel or white membranes. Real-world output tracks 381.2 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Hyperion Solar HY-DH108P8-410-T by Hyperion Solar grounded in CEC test data and NEC 690.7/690.8 limits.

What fuse or breaker size does NEC 690.8 require for Hyperion Solar HY-DH108P8-410-T?

Multiplying Hyperion Solar HY-DH108P8-410-T's 13.95 A short-circuit current by 1.56 equals 21.76 A minimum ampacity, requiring at least a 25 A overcurrent fuse or breaker.

Can Hyperion Solar HY-DH108P8-410-T pair with microinverters instead of a 600 V string inverter?

Yes—if the microinverter DC input ceiling exceeds 41.33 V cold Voc at 14 F and handles 13.95 A Isc; string inverters cap Hyperion Solar HY-DH108P8-410-T at 14 panels on 600 V.

Is Hyperion Solar HY-DH108P8-410-T eligible for the 30% federal 25D solar credit in 2026?

No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of Hyperion Solar HY-DH108P8-410-T rely on utility bill offset (~$2,052/yr at 8 kW) rather than 25D.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.