Skip to main content
WireAndSun
Calculators
CEC PV Module

HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S435XI — CEC Solar Module Specifications

Manufacturer: HD HYUNDAI ENERGY SOLUTIONS CO LTD Registry: CEC Verified Engineering Specification

HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S435XI is a 435.0 W STC (408.2 W PTC) Mono-c-Si solar module ranking #6,850 of 21,677 CEC listings (top 33.5%; higher than 66.5% of peers). It delivers 20.05% efficiency, 49.2 V Voc at 25 C, and 53.09 V cold Voc at -10 C (11 panels max per 600 V string).

STC Wattage
435.0 W
PTC Wattage
408.2 W
Voc @ 25C
49.2 V
Efficiency
20.05%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S435XI Compare Against Peer CEC Listings?

How HD HYUNDAI ENERGY SOLUTIONS CO LTD HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S435XI handles rooftop heat (408.2 W PTC), 8 kW sizing, and cold winter string voltage.

For NEC string engineering, HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S435XI exhibits 11.25 A short-circuit current, requiring a 17.55 A (156%) conductor rating and 20 A OCPD under NEC 690.8. Ranked #6,850 of 21,677 (25.0 W above the 410.0 W Mono-c-Si median), this modern high-density residential and light-commercial module covers 41.2 m2 for an 8 kW system (23 panels for 10 kW). Higher 49.2 V open-circuit voltage caps 600 V residential strings at 11 panels at 14 F (-10 C).

Where Does HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S435XI Fall Across Listed CEC Models?

Where HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S435XI (435.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S435XI (435.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCHD HYUNDAI ENERGY : 435.0 W

What Dataset Percentiles Define HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S435XI?

Percentile placement of HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S435XI across power density (200.5 W/m2), thermal retention, and nameplate STC wattage.

HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S435XI Engineering BenchmarksPercentile comparison of HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S435XI wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage435.0 WPTC/STC Retention93.8%Module Efficiency20.05%

What Do the Dataset Ranks Show for HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S435XI?

Four critical engineering numbers homeowners and solar installers check first when reviewing HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S435XI specifications.

Rank #6,850 / 21,677

Top 33.5% STC Output

435.0 W STC (+50.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #10,276

20.05% Aperture Efficiency

Power density 200.5 W/m2 (0.14 percentage points above 19.91% CEC median). PTC/STC ratio: 93.8% (rank #5,632).

NEC 690.7 Limit

11 Panels Max @ -10 C (600 V)

Cold Voc reaches 53.09 V at -10 C (584.0 V string) and 54.2 V at -20 C (11 max).

8 kW Reference Array

19 Panels = 8,265 W STC

Occupies 41.2 m2 (444 sq ft) producing 7,756 W PTC; NEC 690.8 OCPD floor is 17.55 A (20 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 49.2 * (1 + (-0.226/100) * (-10 - 25)) = 53.09 V | OCPD = 1.56 * 11.25 = 17.55 A

Inputs from CEC Modules.csv for HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S435XI: Voc=49.2 V, beta_Voc=-0.226%/C, Isc=11.25 A, STC=435.0 W, Area=2.17 m2.

Result: 11 panels max on 600 V (584.0 V); 19 panels for 8 kW (444 sq ft).

What Are the Published CEC Specifications for HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S435XI?

Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S435XI.

Official California Energy Commission (NREL SAM) test parameters for HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S435XI.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 435.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 408.2 W (93.8% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 49.2 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 11.25 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 41.0 V / 10.61 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.226 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 20.05% (2.17 m2) Array roof footprint density
Cell Count & Technology 72 cells (Mono-c-Si) Monofacial backsheet

How Many HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S435XI Panels Build a 6 kW, 8 kW, or 10 kW Array?

Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S435XI (435.0 W).

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 14 6.09 kW 327 sq ft $1,524 $2,577
8 kW Class 19 8.27 kW 444 sq ft $2,070 $3,500
10 kW Class 23 10.01 kW 537 sq ft $2,505 $4,236

Which Sibling Wattage & Trim Variants Belong to This HD HYUNDAI ENERGY SOLUTIONS CO LTD Series?

All closely matched HD HYUNDAI ENERGY SOLUTIONS CO LTD wattages and cosmetic trims sharing the HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S435XI architecture.

Sibling CEC listings grouped into the HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S435XI wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S425XI 425.0 W 398.6 W 48.8 V 40.6 V 19.59%
HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S430XI 430.0 W 403.4 W 49.0 V 40.8 V 19.82%
HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S435XI 435.0 W 408.2 W 49.2 V 41.0 V 20.05%
HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S440XI 440.0 W 413.0 W 49.4 V 41.2 V 20.28%
HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S445XI 445.0 W 417.8 W 49.6 V 41.4 V 20.51%

How Many HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S435XI Modules Fit in a Cold-Weather String?

Maximum series module counts for HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S435XI from 25 C down to -20 C (-4 F) under NEC 690.7.

Computed from Voc=49.2V and beta_Voc=-0.226%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 54.2 V 11 panels 596.2 V 18 panels
-10 C (14 F) 53.09 V 11 panels 584.0 V 18 panels
0 C (32 F) 51.98 V 11 panels 571.8 V 19 panels
25 C (77 F STC) 49.2 V 12 panels 590.4 V 20 panels

Which Cross-Brand Solar Modules Compare Closest to HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S435XI?

Alternative CEC solar modules from competing brands near HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S435XI (435.0 W), including AXITEC AC-435MB/144V.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
AXITEC AC-435MB/144V
AXITEC
435.0 W Tie (0 W) 49.1 V 20.33% 92.6%
Dehui Solar Power (Vietnam) CoLtd DH-M772F 435W
Dehui Solar Power (Vietnam) CoLtd
435.0 W Tie (0 W) 49.1 V 20.33% 92.6%
AXITEC AC-435MH/144V
AXITEC
435.0 W Tie (0 W) 49.4 V 20.52% 92.4%
Dehui Solar Power (Vietnam) CoLtd DH-M772W 435W
Dehui Solar Power (Vietnam) CoLtd
435.0 W Tie (0 W) 49.4 V 20.52% 92.4%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S435XI?

Evaluate HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S435XI (435.0 W STC, 49.2 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S435XI reaches 54.2 V per panel—exceeding 11 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 19 panels for an 8 kW build require 444 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 19 panels (444 sq ft) for an 8 kW array.
  • 2026 tax credit baseline: cash residential installs of HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S435XI carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S435XI 8 kW Residential Fit

Needs 19 modules (444 sq ft) with a 20 A string OCPD, offsetting ~$2,070/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 11 panels (-10 C) or 11 panels (-20 C), or compare AXITEC AC-435MB/144V.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 408.2 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S435XI by HD HYUNDAI ENERGY SOLUTIONS CO LTD grounded in CEC test data and NEC 690.7/690.8 limits.

Why is HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S435XI PTC wattage (408.2 W) lower than STC (435.0 W)?

Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 408.2 W PTC (93.8% retention) across HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S435XI's 2.17 m2 aperture.

Who should skip HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S435XI on a complex residential roof?

Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 19 HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S435XI panels (444 sq ft) leave unusable roof gaps vs. AXITEC AC-435MB/144V.

What is the 1,000 V commercial string limit for HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S435XI?

On 1,000 V commercial inverters at -10 C (53.09 V cold Voc), HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S435XI fits up to 18 panels per series string.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.