Hanwha Qcells (Qidong) Co Ltd SF160-24-P175 is a 175.0 W STC (154.5 W PTC) Multi-c-Si solar module ranking #21,282 of 21,677 CEC listings (below all-CEC median; higher than 1.6% of peers). It delivers 13.71% efficiency, 44.5 V Voc at 25 C, and 49.8 V cold Voc at -10 C (12 panels max per 600 V string).
- STC Wattage
- 175.0 W
- PTC Wattage
- 154.5 W
- Voc @ 25C
- 44.5 V
- Efficiency
- 13.71%
How Does Hanwha Qcells (Qidong) Co Ltd SF160-24-P175 Compare Against Peer CEC Listings?
How Hanwha Qcells (Qidong) Co Ltd Hanwha Qcells (Qidong) Co Ltd SF160-24-P175 handles rooftop heat (154.5 W PTC), 8 kW sizing, and cold winter string voltage.
Hanwha Qcells (Qidong) Co Ltd builds the Hanwha Qcells (Qidong) Co Ltd SF160-24-P175 (Multi-c-Si) as a compact residential or specialty off-grid module delivering 137.0 W/m2 (6.20 percentage points below 19.91% CEC median). Compared against Solarbest Energy-Tech (Zhejiang) ZSB-M180(125) (180.0 W), this model holds typical 88.3% PTC-to-STC thermal output (154.5 W real-world rating). Mid-range 44.5 V open-circuit voltage allows up to 12 panels per 600 V string at 14 F, while NEC 690.8 sets a 8.11 A overcurrent floor served by a 15 A breaker.
Where Does Hanwha Qcells (Qidong) Co Ltd SF160-24-P175 Fall Across Listed CEC Models?
Where Hanwha Qcells (Qidong) Co Ltd SF160-24-P175 (175.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.
What Dataset Percentiles Define Hanwha Qcells (Qidong) Co Ltd SF160-24-P175?
Percentile placement of Hanwha Qcells (Qidong) Co Ltd SF160-24-P175 across power density (137.0 W/m2), thermal retention, and nameplate STC wattage.
What Do the Dataset Ranks Show for Hanwha Qcells (Qidong) Co Ltd SF160-24-P175?
Four critical engineering numbers homeowners and solar installers check first when reviewing Hanwha Qcells (Qidong) Co Ltd SF160-24-P175 specifications.
175.0 W STC · Higher Than 1.6%
175.0 W STC (-210.0 W vs all-CEC median) vs 278.8 W Multi-c-Si median.
13.71% Aperture Efficiency
Power density 137.0 W/m2 (6.20 percentage points below 19.91% CEC median). PTC/STC ratio: 88.3% (rank #21,245).
12 Panels Max @ -10 C (600 V)
Cold Voc reaches 49.8 V at -10 C (597.6 V string) and 51.31 V at -20 C (11 max).
46 Panels = 8,050 W STC
Occupies 58.7 m2 (632 sq ft) producing 7,107 W PTC; NEC 690.8 OCPD floor is 8.11 A (15 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 44.5 * (1 + (-0.34/100) * (-10 - 25)) = 49.8 V | OCPD = 1.56 * 5.2 = 8.11 A
Inputs from CEC Modules.csv for Hanwha Qcells (Qidong) Co Ltd SF160-24-P175: Voc=44.5 V, beta_Voc=-0.34%/C, Isc=5.2 A, STC=175.0 W, Area=1.277 m2.
Result: 12 panels max on 600 V (597.6 V); 46 panels for 8 kW (632 sq ft).
What Are the Published CEC Specifications for Hanwha Qcells (Qidong) Co Ltd SF160-24-P175?
Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for Hanwha Qcells (Qidong) Co Ltd SF160-24-P175.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 175.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 154.5 W (88.3% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 44.5 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 5.2 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 35.7 V / 4.9 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.34 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 13.71% (1.277 m2) | Array roof footprint density |
| Cell Count & Technology | 72 cells (Multi-c-Si) | Monofacial backsheet |
How Many Hanwha Qcells (Qidong) Co Ltd SF160-24-P175 Panels Build a 6 kW, 8 kW, or 10 kW Array?
Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using Hanwha Qcells (Qidong) Co Ltd SF160-24-P175 (175.0 W).
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 35 | 6.12 kW | 481 sq ft | $1,532 | $2,590 |
| 8 kW Class | 46 | 8.05 kW | 632 sq ft | $2,015 | $3,407 |
| 10 kW Class | 58 | 10.15 kW | 797 sq ft | $2,540 | $4,296 |
How Many Hanwha Qcells (Qidong) Co Ltd SF160-24-P175 Modules Fit in a Cold-Weather String?
Maximum series module counts for Hanwha Qcells (Qidong) Co Ltd SF160-24-P175 from 25 C down to -20 C (-4 F) under NEC 690.7.
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 51.31 V | 11 panels | 564.4 V | 19 panels |
| -10 C (14 F) | 49.8 V | 12 panels | 597.6 V | 20 panels |
| 0 C (32 F) | 48.28 V | 12 panels | 579.4 V | 20 panels |
| 25 C (77 F STC) | 44.5 V | 13 panels | 578.5 V | 22 panels |
Which Cross-Brand Solar Modules Compare Closest to Hanwha Qcells (Qidong) Co Ltd SF160-24-P175?
Alternative CEC solar modules from competing brands near Hanwha Qcells (Qidong) Co Ltd SF160-24-P175 (175.0 W), including Solarbest Energy-Tech (Zhejiang) ZSB-M180(125).
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| Solarbest Energy-Tech (Zhejiang) ZSB-M180(125) Solarbest Energy-Tech (Zhejiang) |
180.0 W | +5.0 W | 44.35 V | 14.1% | 89.8% |
| Enp Sonne Solar Technikk ENP-M170MO Enp Sonne Solar Technikk |
170.0 W | -5.0 W | 44.2 V | 13.29% | 89.3% |
| Guangdong Golden Glass Technologies GG180S1-36/1589x807 Guangdong Golden Glass Technologies |
180.0 W | +5.0 W | 44.2 V | 14.04% | 90.8% |
| Trina Solar TSM-180DA01 Trina Solar |
180.0 W | +5.0 W | 44.2 V | 14.26% | 90.6% |
What Are the Design Limits and Best-Fit Uses for Hanwha Qcells (Qidong) Co Ltd SF160-24-P175?
Evaluate Hanwha Qcells (Qidong) Co Ltd SF160-24-P175 (175.0 W STC, 44.5 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), Hanwha Qcells (Qidong) Co Ltd SF160-24-P175 reaches 51.31 V per panel—exceeding 11 panels in series voids 600 V inverter warranties.
- Footprint constraint: 46 panels for an 8 kW build require 632 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 46 panels (632 sq ft).
- 2026 tax credit baseline: cash residential installs of Hanwha Qcells (Qidong) Co Ltd SF160-24-P175 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
Hanwha Qcells (Qidong) Co Ltd SF160-24-P175 8 kW Residential Fit
Needs 46 modules (632 sq ft) with a 15 A string OCPD, offsetting ~$2,015/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 12 panels (-10 C) or 11 panels (-20 C), or compare Solarbest Energy-Tech (Zhejiang) ZSB-M180(125).
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 154.5 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for Hanwha Qcells (Qidong) Co Ltd SF160-24-P175 by Hanwha Qcells (Qidong) Co Ltd grounded in CEC test data and NEC 690.7/690.8 limits.
What fuse or breaker size does NEC 690.8 require for Hanwha Qcells (Qidong) Co Ltd SF160-24-P175?
Multiplying Hanwha Qcells (Qidong) Co Ltd SF160-24-P175's 5.2 A short-circuit current by 1.56 equals 8.11 A minimum ampacity, requiring at least a 15 A overcurrent fuse or breaker.
Can Hanwha Qcells (Qidong) Co Ltd SF160-24-P175 pair with microinverters instead of a 600 V string inverter?
Yes—if the microinverter DC input ceiling exceeds 49.8 V cold Voc at 14 F and handles 5.2 A Isc; string inverters cap Hanwha Qcells (Qidong) Co Ltd SF160-24-P175 at 12 panels on 600 V.
Is Hanwha Qcells (Qidong) Co Ltd SF160-24-P175 eligible for the 30% federal 25D solar credit in 2026?
No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of Hanwha Qcells (Qidong) Co Ltd SF160-24-P175 rely on utility bill offset (~$2,015/yr at 8 kW) rather than 25D.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)