Hanwha Qcells (Qidong) Co Ltd HSL60P6-PB-4-260TW is a 260.0 W STC (233.1 W PTC) Multi-c-Si solar module ranking #19,146 of 21,677 CEC listings (below all-CEC median; higher than 10.4% of peers). It delivers 16.24% efficiency, 37.7 V Voc at 25 C, and 42.45 V cold Voc at -10 C (14 panels max per 600 V string).
- STC Wattage
- 260.0 W
- PTC Wattage
- 233.1 W
- Voc @ 25C
- 37.7 V
- Efficiency
- 16.24%
How Does Hanwha Qcells (Qidong) Co Ltd HSL60P6-PB-4-260TW Compare Against Peer CEC Listings?
Solar engineering breakdown for Hanwha Qcells (Qidong) Co Ltd HSL60P6-PB-4-260TW: PTC thermal retention, roof footprint, and cold Voc string bounds.
Across 1,407 Multi-c-Si listings from Hanwha Qcells (Qidong) Co Ltd and peers, Hanwha Qcells (Qidong) Co Ltd HSL60P6-PB-4-260TW stands 18.8 W below the 278.8 W Multi-c-Si median and typical 89.7% PTC-to-STC thermal output (233.1 W real-world rating). Sizing 6 kW (24 panels) to 10 kW (39 panels) yields $1,562-$2,538/yr in baseline US bill offset. Lower 37.7 V string voltage fits 14 panels in series at 14 F and pairs easily with microinverters.
Where Does Hanwha Qcells (Qidong) Co Ltd HSL60P6-PB-4-260TW Fall Across Listed CEC Models?
Distribution marker showing Hanwha Qcells (Qidong) Co Ltd HSL60P6-PB-4-260TW (260.0 W) relative to the 385.0 W all-CEC solar panel median.
What Dataset Percentiles Define Hanwha Qcells (Qidong) Co Ltd HSL60P6-PB-4-260TW?
Dataset percentiles tracking Hanwha Qcells (Qidong) Co Ltd HSL60P6-PB-4-260TW power output, thermal retention ratio, and aperture efficiency against 21,677 models.
What Do the Dataset Ranks Show for Hanwha Qcells (Qidong) Co Ltd HSL60P6-PB-4-260TW?
Benchmark highlights for Hanwha Qcells (Qidong) Co Ltd HSL60P6-PB-4-260TW covering STC output, efficiency, 8 kW footprint, and OCPD breaker size.
260.0 W STC · Higher Than 10.4%
260.0 W STC (-125.0 W vs all-CEC median) vs 278.8 W Multi-c-Si median.
16.24% Aperture Efficiency
Power density 162.4 W/m2 (3.67 percentage points below 19.91% CEC median). PTC/STC ratio: 89.7% (rank #19,653).
14 Panels Max @ -10 C (600 V)
Cold Voc reaches 42.45 V at -10 C (594.3 V string) and 43.81 V at -20 C (13 max).
31 Panels = 8,060 W STC
Occupies 49.6 m2 (534 sq ft) producing 7,226 W PTC; NEC 690.8 OCPD floor is 14.02 A (15 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 37.7 * (1 + (-0.36/100) * (-10 - 25)) = 42.45 V | OCPD = 1.56 * 8.99 = 14.02 A
Inputs from CEC Modules.csv for Hanwha Qcells (Qidong) Co Ltd HSL60P6-PB-4-260TW: Voc=37.7 V, beta_Voc=-0.36%/C, Isc=8.99 A, STC=260.0 W, Area=1.601 m2.
Result: 14 panels max on 600 V (594.3 V); 31 panels for 8 kW (534 sq ft).
What Are the Published CEC Specifications for Hanwha Qcells (Qidong) Co Ltd HSL60P6-PB-4-260TW?
Official CEC datasheet figures for Hanwha Qcells (Qidong) Co Ltd HSL60P6-PB-4-260TW (Multi-c-Si) used in utility interconnection and permit reviews.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 260.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 233.1 W (89.7% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 37.7 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 8.99 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 30.4 V / 8.56 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.36 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 16.24% (1.601 m2) | Array roof footprint density |
| Cell Count & Technology | 60 cells (Multi-c-Si) | Monofacial backsheet |
How Many Hanwha Qcells (Qidong) Co Ltd HSL60P6-PB-4-260TW Panels Build a 6 kW, 8 kW, or 10 kW Array?
How many Hanwha Qcells (Qidong) Co Ltd HSL60P6-PB-4-260TW modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 24 | 6.24 kW | 414 sq ft | $1,562 | $2,641 |
| 8 kW Class | 31 | 8.06 kW | 534 sq ft | $2,017 | $3,411 |
| 10 kW Class | 39 | 10.14 kW | 672 sq ft | $2,538 | $4,292 |
Which Sibling Wattage & Trim Variants Belong to This Hanwha Qcells (Qidong) Co Ltd Series?
Consolidated Hanwha Qcells (Qidong) Co Ltd wattage variants sharing the Hanwha Qcells (Qidong) Co Ltd HSL60P6-PB-4-260TW mechanical and cell layout.
| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| Hanwha Qcells (Qidong) Co Ltd HSL60P6-PB-4-250TW | 250.0 W | 225.2 W | 37.4 V | 30.0 V | 15.47% |
| Hanwha Qcells (Qidong) Co Ltd HSL60P6-PB-4-255TW | 255.0 W | 228.8 W | 37.5 V | 30.1 V | 15.78% |
| Hanwha Qcells (Qidong) Co Ltd HSL60P6-PB-4-260TW | 260.0 W | 233.1 W | 37.7 V | 30.4 V | 16.24% |
| Hanwha Qcells (Qidong) Co Ltd HSL60P6-PB-4-265TW | 265.0 W | 237.8 W | 37.8 V | 30.6 V | 16.56% |
| Hanwha Qcells (Qidong) Co Ltd HSL60P6-PB-4-270TW | 270.0 W | 242.4 W | 37.8 V | 30.8 V | 16.87% |
How Many Hanwha Qcells (Qidong) Co Ltd HSL60P6-PB-4-260TW Modules Fit in a Cold-Weather String?
NEC 690.7(A) winter string table preventing overvoltage trips on Hanwha Qcells (Qidong) Co Ltd HSL60P6-PB-4-260TW (42.45 V at 14 F).
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 43.81 V | 13 panels | 569.5 V | 22 panels |
| -10 C (14 F) | 42.45 V | 14 panels | 594.3 V | 23 panels |
| 0 C (32 F) | 41.09 V | 14 panels | 575.3 V | 24 panels |
| 25 C (77 F STC) | 37.7 V | 15 panels | 565.5 V | 26 panels |
Which Cross-Brand Solar Modules Compare Closest to Hanwha Qcells (Qidong) Co Ltd HSL60P6-PB-4-260TW?
Competing CEC solar panels closest to Hanwha Qcells (Qidong) Co Ltd HSL60P6-PB-4-260TW in nameplate wattage and Voc, starting with AXITEC AC-260M/156-60S.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| AXITEC AC-260M/156-60S AXITEC |
260.0 W | Tie (0 W) | 37.73 V | 16.02% | 90.2% |
| AXITEC AC-260P/156-60S AXITEC |
260.0 W | Tie (0 W) | 37.65 V | 16.02% | 89.0% |
| Centrosolar America EP6 260BW Centrosolar America |
260.0 W | Tie (0 W) | 37.65 V | 16.02% | 89.0% |
| Centrosolar America EP6 260SW Centrosolar America |
260.0 W | Tie (0 W) | 37.65 V | 16.02% | 89.0% |
What Are the Design Limits and Best-Fit Uses for Hanwha Qcells (Qidong) Co Ltd HSL60P6-PB-4-260TW?
Evaluate Hanwha Qcells (Qidong) Co Ltd HSL60P6-PB-4-260TW (260.0 W STC, 37.7 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), Hanwha Qcells (Qidong) Co Ltd HSL60P6-PB-4-260TW reaches 43.81 V per panel—exceeding 13 panels in series voids 600 V inverter warranties.
- Footprint constraint: 31 panels for an 8 kW build require 534 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 31 panels (534 sq ft).
- 2026 tax credit baseline: cash residential installs of Hanwha Qcells (Qidong) Co Ltd HSL60P6-PB-4-260TW carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
Hanwha Qcells (Qidong) Co Ltd HSL60P6-PB-4-260TW 8 kW Residential Fit
Needs 31 modules (534 sq ft) with a 15 A string OCPD, offsetting ~$2,017/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 14 panels (-10 C) or 13 panels (-20 C), or compare AXITEC AC-260M/156-60S.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 233.1 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for Hanwha Qcells (Qidong) Co Ltd HSL60P6-PB-4-260TW by Hanwha Qcells (Qidong) Co Ltd grounded in CEC test data and NEC 690.7/690.8 limits.
What fuse or breaker size does NEC 690.8 require for Hanwha Qcells (Qidong) Co Ltd HSL60P6-PB-4-260TW?
Multiplying Hanwha Qcells (Qidong) Co Ltd HSL60P6-PB-4-260TW's 8.99 A short-circuit current by 1.56 equals 14.02 A minimum ampacity, requiring at least a 15 A overcurrent fuse or breaker.
Can Hanwha Qcells (Qidong) Co Ltd HSL60P6-PB-4-260TW pair with microinverters instead of a 600 V string inverter?
Yes—if the microinverter DC input ceiling exceeds 42.45 V cold Voc at 14 F and handles 8.99 A Isc; string inverters cap Hanwha Qcells (Qidong) Co Ltd HSL60P6-PB-4-260TW at 14 panels on 600 V.
Is Hanwha Qcells (Qidong) Co Ltd HSL60P6-PB-4-260TW eligible for the 30% federal 25D solar credit in 2026?
No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of Hanwha Qcells (Qidong) Co Ltd HSL60P6-PB-4-260TW rely on utility bill offset (~$2,017/yr at 8 kW) rather than 25D.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)