Hansol Technics Co Ltd HS400UD-JH2 is a 400.0 W STC (375.3 W PTC) Mono-c-Si solar module ranking #9,407 of 21,677 CEC listings (top 45.5%; higher than 54.5% of peers). It delivers 20.74% efficiency, 48.7 V Voc at 25 C, and 53.44 V cold Voc at -10 C (11 panels max per 600 V string).
- STC Wattage
- 400.0 W
- PTC Wattage
- 375.3 W
- Voc @ 25C
- 48.7 V
- Efficiency
- 20.74%
How Does Hansol Technics Co Ltd HS400UD-JH2 Compare Against Peer CEC Listings?
How Hansol Technics Co Ltd Hansol Technics Co Ltd HS400UD-JH2 handles rooftop heat (375.3 W PTC), 8 kW sizing, and cold winter string voltage.
Hansol Technics Co Ltd builds the Hansol Technics Co Ltd HS400UD-JH2 (Mono-c-Si) as a modern high-density residential and light-commercial module delivering 207.4 W/m2 (0.83 percentage points above 19.91% CEC median). Compared against Boviet Solar Technology Co Ltd BVM6612M-400-H (400.0 W), this model holds strong 93.8% PTC-to-STC heat retention (#5,632 of 21,677). Higher 48.7 V open-circuit voltage caps 600 V residential strings at 11 panels at 14 F (-10 C), while NEC 690.8 sets a 16.05 A overcurrent floor served by a 20 A breaker.
Where Does Hansol Technics Co Ltd HS400UD-JH2 Fall Across Listed CEC Models?
Where Hansol Technics Co Ltd HS400UD-JH2 (400.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.
What Dataset Percentiles Define Hansol Technics Co Ltd HS400UD-JH2?
Percentile placement of Hansol Technics Co Ltd HS400UD-JH2 across power density (207.4 W/m2), thermal retention, and nameplate STC wattage.
What Do the Dataset Ranks Show for Hansol Technics Co Ltd HS400UD-JH2?
Four critical engineering numbers homeowners and solar installers check first when reviewing Hansol Technics Co Ltd HS400UD-JH2 specifications.
Top 45.5% STC Output
400.0 W STC (+15.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.
20.74% Aperture Efficiency
Power density 207.4 W/m2 (0.83 percentage points above 19.91% CEC median). PTC/STC ratio: 93.8% (rank #5,632).
11 Panels Max @ -10 C (600 V)
Cold Voc reaches 53.44 V at -10 C (587.8 V string) and 54.79 V at -20 C (10 max).
20 Panels = 8,000 W STC
Occupies 38.6 m2 (415 sq ft) producing 7,506 W PTC; NEC 690.8 OCPD floor is 16.05 A (20 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 48.7 * (1 + (-0.278/100) * (-10 - 25)) = 53.44 V | OCPD = 1.56 * 10.29 = 16.05 A
Inputs from CEC Modules.csv for Hansol Technics Co Ltd HS400UD-JH2: Voc=48.7 V, beta_Voc=-0.278%/C, Isc=10.29 A, STC=400.0 W, Area=1.929 m2.
Result: 11 panels max on 600 V (587.8 V); 20 panels for 8 kW (415 sq ft).
What Are the Published CEC Specifications for Hansol Technics Co Ltd HS400UD-JH2?
Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for Hansol Technics Co Ltd HS400UD-JH2.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 400.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 375.3 W (93.8% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 48.7 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 10.29 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 41.1 V / 9.74 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.278 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 20.74% (1.929 m2) | Array roof footprint density |
| Cell Count & Technology | 72 cells (Mono-c-Si) | Monofacial backsheet |
How Many Hansol Technics Co Ltd HS400UD-JH2 Panels Build a 6 kW, 8 kW, or 10 kW Array?
Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using Hansol Technics Co Ltd HS400UD-JH2 (400.0 W).
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 15 | 6.0 kW | 311 sq ft | $1,502 | $2,539 |
| 8 kW Class | 20 | 8.0 kW | 415 sq ft | $2,002 | $3,386 |
| 10 kW Class | 25 | 10.0 kW | 519 sq ft | $2,503 | $4,232 |
How Many Hansol Technics Co Ltd HS400UD-JH2 Modules Fit in a Cold-Weather String?
Maximum series module counts for Hansol Technics Co Ltd HS400UD-JH2 from 25 C down to -20 C (-4 F) under NEC 690.7.
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 54.79 V | 10 panels | 547.9 V | 18 panels |
| -10 C (14 F) | 53.44 V | 11 panels | 587.8 V | 18 panels |
| 0 C (32 F) | 52.08 V | 11 panels | 572.9 V | 19 panels |
| 25 C (77 F STC) | 48.7 V | 12 panels | 584.4 V | 20 panels |
Which Cross-Brand Solar Modules Compare Closest to Hansol Technics Co Ltd HS400UD-JH2?
Alternative CEC solar modules from competing brands near Hansol Technics Co Ltd HS400UD-JH2 (400.0 W), including Boviet Solar Technology Co Ltd BVM6612M-400-H.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| Boviet Solar Technology Co Ltd BVM6612M-400-H Boviet Solar Technology Co Ltd |
400.0 W | Tie (0 W) | 49.2 V | 20.62% | 93.2% |
| Boviet Solar Technology Co Ltd BVM6612M-W5-400-H Boviet Solar Technology Co Ltd |
400.0 W | Tie (0 W) | 49.2 V | 20.62% | 93.2% |
| Aptos Solar Technology LLC DNA-144-MF23-405W {Blk} Aptos Solar Technology LLC |
405.0 W | +5.0 W | 48.73 V | 20.13% | 90.8% |
| Aptos Solar Technology LLC DNA-144-MF23-405W {Wht} Aptos Solar Technology LLC |
405.0 W | +5.0 W | 48.73 V | 20.77% | 93.5% |
What Are the Design Limits and Best-Fit Uses for Hansol Technics Co Ltd HS400UD-JH2?
Evaluate Hansol Technics Co Ltd HS400UD-JH2 (400.0 W STC, 48.7 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), Hansol Technics Co Ltd HS400UD-JH2 reaches 54.79 V per panel—exceeding 10 panels in series voids 600 V inverter warranties.
- Footprint constraint: 20 panels for an 8 kW build require 415 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 20 panels (415 sq ft) for an 8 kW array.
- 2026 tax credit baseline: cash residential installs of Hansol Technics Co Ltd HS400UD-JH2 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
Hansol Technics Co Ltd HS400UD-JH2 8 kW Residential Fit
Needs 20 modules (415 sq ft) with a 20 A string OCPD, offsetting ~$2,002/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 11 panels (-10 C) or 10 panels (-20 C), or compare Boviet Solar Technology Co Ltd BVM6612M-400-H.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 375.3 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for Hansol Technics Co Ltd HS400UD-JH2 by Hansol Technics Co Ltd grounded in CEC test data and NEC 690.7/690.8 limits.
What fuse or breaker size does NEC 690.8 require for Hansol Technics Co Ltd HS400UD-JH2?
Multiplying Hansol Technics Co Ltd HS400UD-JH2's 10.29 A short-circuit current by 1.56 equals 16.05 A minimum ampacity, requiring at least a 20 A overcurrent fuse or breaker.
Can Hansol Technics Co Ltd HS400UD-JH2 pair with microinverters instead of a 600 V string inverter?
Yes—if the microinverter DC input ceiling exceeds 53.44 V cold Voc at 14 F and handles 10.29 A Isc; string inverters cap Hansol Technics Co Ltd HS400UD-JH2 at 11 panels on 600 V.
Is Hansol Technics Co Ltd HS400UD-JH2 eligible for the 30% federal 25D solar credit in 2026?
No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of Hansol Technics Co Ltd HS400UD-JH2 rely on utility bill offset (~$2,002/yr at 8 kW) rather than 25D.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)