Skip to main content
WireAndSun
Calculators
CEC PV Module

Hansol Technics Co Ltd HS390UE-AN1 — CEC Solar Module Specifications

Manufacturer: Hansol Technics Co Ltd Registry: CEC Verified Engineering Specification

Hansol Technics Co Ltd HS390UE-AN1 is a 390.0 W STC (359.6 W PTC) Mono-c-Si solar module ranking #10,321 of 21,677 CEC listings (top 49.5%; higher than 50.5% of peers). It delivers 18.66% efficiency, 50.5 V Voc at 25 C, and 55.47 V cold Voc at -10 C (10 panels max per 600 V string).

STC Wattage
390.0 W
PTC Wattage
359.6 W
Voc @ 25C
50.5 V
Efficiency
18.66%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does Hansol Technics Co Ltd HS390UE-AN1 Compare Against Peer CEC Listings?

CEC rank, roof space requirements, and NEC 690.7/690.8 limits for Hansol Technics Co Ltd HS390UE-AN1 (Mono-c-Si) residential solar systems.

Hansol Technics Co Ltd HS390UE-AN1 delivers 186.6 W/m2 (1.25 percentage points below 19.91% CEC median) and strong 92.2% PTC-to-STC heat retention (#13,542 of 21,677), placing it as a modern high-density residential and light-commercial module well-proportioned for residential pitched roofs needing 21 panels (472 sq ft) for an 8 kW array. At -4 F (-20 C), string voltage climbs to 56.89 V per unit, capping 600 V circuits at 10 panels. Compare specs directly with CSI Solar Co Ltd CS1Y-390MS (390.0 W).

Where Does Hansol Technics Co Ltd HS390UE-AN1 Fall Across Listed CEC Models?

Comparison of Hansol Technics Co Ltd HS390UE-AN1 (390.0 W STC) against all 21,677 California Energy Commission certified photovoltaic modules.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where Hansol Technics Co Ltd HS390UE-AN1 (390.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCHansol Technics Co: 390.0 W

What Dataset Percentiles Define Hansol Technics Co Ltd HS390UE-AN1?

Relative ranking of Hansol Technics Co Ltd HS390UE-AN1 across nameplate watts, 92.2% PTC thermal ratio, and module aperture efficiency.

Hansol Technics Co Ltd HS390UE-AN1 Engineering BenchmarksPercentile comparison of Hansol Technics Co Ltd HS390UE-AN1 wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage390.0 WPTC/STC Retention92.2%Module Efficiency18.66%

What Do the Dataset Ranks Show for Hansol Technics Co Ltd HS390UE-AN1?

Summary of Hansol Technics Co Ltd HS390UE-AN1 output rank, 8 kW array size (21 panels), efficiency rating, and 600 V string limit.

Rank #10,321 / 21,677

Top 49.5% STC Output

390.0 W STC (+5.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #14,080

18.66% Aperture Efficiency

Power density 186.6 W/m2 (1.25 percentage points below 19.91% CEC median). PTC/STC ratio: 92.2% (rank #13,542).

NEC 690.7 Limit

10 Panels Max @ -10 C (600 V)

Cold Voc reaches 55.47 V at -10 C (554.7 V string) and 56.89 V at -20 C (10 max).

8 kW Reference Array

21 Panels = 8,190 W STC

Occupies 43.9 m2 (472 sq ft) producing 7,552 W PTC; NEC 690.8 OCPD floor is 16.26 A (20 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 50.5 * (1 + (-0.281/100) * (-10 - 25)) = 55.47 V | OCPD = 1.56 * 10.42 = 16.26 A

Inputs from CEC Modules.csv for Hansol Technics Co Ltd HS390UE-AN1: Voc=50.5 V, beta_Voc=-0.281%/C, Isc=10.42 A, STC=390.0 W, Area=2.09 m2.

Result: 10 panels max on 600 V (554.7 V); 21 panels for 8 kW (472 sq ft).

What Are the Published CEC Specifications for Hansol Technics Co Ltd HS390UE-AN1?

Complete CEC test sheet for Hansol Technics Co Ltd HS390UE-AN1 including Isc (10.42 A), Voc (50.5 V), and thermal temperature coefficients.

Official California Energy Commission (NREL SAM) test parameters for Hansol Technics Co Ltd HS390UE-AN1.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 390.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 359.6 W (92.2% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 50.5 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 10.42 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 40.9 V / 9.54 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.281 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 18.66% (2.09 m2) Array roof footprint density
Cell Count & Technology 78 cells (Mono-c-Si) Monofacial backsheet

How Many Hansol Technics Co Ltd HS390UE-AN1 Panels Build a 6 kW, 8 kW, or 10 kW Array?

Residential array count and annual electric bill savings at 18.54 c/kWh US avg vs. California tariffs using Hansol Technics Co Ltd HS390UE-AN1.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 16 6.24 kW 360 sq ft $1,562 $2,641
8 kW Class 21 8.19 kW 472 sq ft $2,050 $3,466
10 kW Class 26 10.14 kW 585 sq ft $2,538 $4,292

Which Sibling Wattage & Trim Variants Belong to This Hansol Technics Co Ltd Series?

Related Hansol Technics Co Ltd power steps and black/silver trims consolidated into this Hansol Technics Co Ltd HS390UE-AN1 series guide.

Sibling CEC listings grouped into the Hansol Technics Co Ltd HS390UE-AN1 wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
Hansol Technics Co Ltd HS380UE-AN1 380.0 W 350.1 W 49.7 V 40.1 V 18.18%
Hansol Technics Co Ltd HS385UE-AN1 385.0 W 354.9 W 50.1 V 40.5 V 18.42%
Hansol Technics Co Ltd HS390UE-AN1 390.0 W 359.6 W 50.5 V 40.9 V 18.66%
Hansol Technics Co Ltd HS395UE-AN1 395.0 W 364.3 W 50.9 V 41.3 V 18.9%

How Many Hansol Technics Co Ltd HS390UE-AN1 Modules Fit in a Cold-Weather String?

Verify freezing-morning voltage rise for Hansol Technics Co Ltd HS390UE-AN1 (50.5 V STC) before wiring 600 V or 1,000 V strings.

Computed from Voc=50.5V and beta_Voc=-0.281%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 56.89 V 10 panels 568.9 V 17 panels
-10 C (14 F) 55.47 V 10 panels 554.7 V 18 panels
0 C (32 F) 54.05 V 11 panels 594.5 V 18 panels
25 C (77 F STC) 50.5 V 11 panels 555.5 V 19 panels

Which Cross-Brand Solar Modules Compare Closest to Hansol Technics Co Ltd HS390UE-AN1?

Four comparable CEC modules such as CSI Solar Co Ltd CS1Y-390MS (390.0 W) for side-by-side solar quote checks.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
CSI Solar Co Ltd CS1Y-390MS
CSI Solar Co Ltd
390.0 W Tie (0 W) 51.9 V 20.0% 94.0%
BYD Company Limited BYD415MIK-36
BYD Company Limited
395.0 W +5.0 W 50.06 V 19.65% 93.9%
ELITE Solar ET-M672BH395GL
ELITE Solar
395.0 W +5.0 W 49.6 V 19.36% 93.2%
ELITE Solar ET-M672BH395WW
ELITE Solar
395.0 W +5.0 W 49.5 V 19.85% 93.3%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for Hansol Technics Co Ltd HS390UE-AN1?

Evaluate Hansol Technics Co Ltd HS390UE-AN1 (390.0 W STC, 50.5 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), Hansol Technics Co Ltd HS390UE-AN1 reaches 56.89 V per panel—exceeding 10 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 21 panels for an 8 kW build require 472 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 21 panels (472 sq ft) for an 8 kW array.
  • 2026 tax credit baseline: cash residential installs of Hansol Technics Co Ltd HS390UE-AN1 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

Hansol Technics Co Ltd HS390UE-AN1 8 kW Residential Fit

Needs 21 modules (472 sq ft) with a 20 A string OCPD, offsetting ~$2,050/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 10 panels (-10 C) or 10 panels (-20 C), or compare CSI Solar Co Ltd CS1Y-390MS.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 359.6 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Hansol Technics Co Ltd HS390UE-AN1 by Hansol Technics Co Ltd grounded in CEC test data and NEC 690.7/690.8 limits.

How many Hansol Technics Co Ltd HS390UE-AN1 panels fit on a 600 V winter solar string?

At -10 C (14 F), Hansol Technics Co Ltd HS390UE-AN1 cold Voc rises from 50.5 V to 55.47 V (beta_Voc -0.281%/C), capping a 600 V string at 10 panels (554.7 V).

How much roof area does an 8 kW array of Hansol Technics Co Ltd HS390UE-AN1 need?

An 8 kW DC system uses 21 Hansol Technics Co Ltd HS390UE-AN1 modules (8,190 W STC / 7,552 W PTC), covering roughly 472 sq ft and saving ~$2,050/yr at 18.54 c/kWh.

How does Hansol Technics Co Ltd HS390UE-AN1 compare against CSI Solar Co Ltd CS1Y-390MS?

Hansol Technics Co Ltd HS390UE-AN1 outputs 390.0 W STC (50.5 V Voc, rank #10,321 of 21,677), while CSI Solar Co Ltd CS1Y-390MS delivers 390.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.