Hansol Technics Co Ltd HS355TD-AN4 — CEC Solar Module Specifications

Manufacturer: Hansol Technics Co Ltd Registry: CEC Verified Engineering Specification

Hansol Technics Co Ltd HS355TD-AN4 is a 355.0 W STC (328.9 W PTC) Mono-c-Si solar module ranking #12,724 of 21,677 CEC listings (below all-CEC median; higher than 39.9% of peers). It delivers 18.35% efficiency, 47.8 V Voc at 25 C, and 52.5 V cold Voc at -10 C (11 panels max per 600 V string).

STC Wattage
355.0 W
PTC Wattage
328.9 W
Voc @ 25C
47.8 V
Efficiency
18.35%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does Hansol Technics Co Ltd HS355TD-AN4 Compare Against Peer CEC Listings?

Engineering position of Hansol Technics Co Ltd HS355TD-AN4 (355.0 W STC) vs. Bluesun Solar Energy Tech CoLtd BSM355P-72 across 5,889 CEC Mono-c-Si solar modules.

Ranking #12,724 across 21,677 CEC solar panels (below all-CEC median; higher than 39.9% of peers), Hansol Technics Co Ltd HS355TD-AN4 operates as a compact residential or specialty off-grid module sitting 55.0 W below the 410.0 W Mono-c-Si median. Mid-range 47.8 V open-circuit voltage allows up to 11 panels per 600 V string at 14 F. With strong 92.6% PTC-to-STC heat retention (#11,981 of 21,677), 23 panels occupy 479 sq ft and offset roughly $2,042/yr at average US rates (or $3,454/yr in California). Monofacial backsheet sealing targets flush dark shingle rooftop mounts.

Where Does Hansol Technics Co Ltd HS355TD-AN4 Fall Across Listed CEC Models?

Plots Hansol Technics Co Ltd HS355TD-AN4 at 355.0 W STC across all 21,677 California Energy Commission photovoltaic modules relative to the 385.0 W median.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where Hansol Technics Co Ltd HS355TD-AN4 (355.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCHansol Technics Co: 355.0 W

What Dataset Percentiles Define Hansol Technics Co Ltd HS355TD-AN4?

Benchmarks Hansol Technics Co Ltd HS355TD-AN4 on STC wattage, thermal PTC/STC retention, and 18.35 aperture conversion efficiency against CEC peers.

Hansol Technics Co Ltd HS355TD-AN4 Engineering BenchmarksPercentile comparison of Hansol Technics Co Ltd HS355TD-AN4 wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage355.0 WPTC/STC Retention92.6%Module Efficiency18.35%

What Do the Dataset Ranks Show for Hansol Technics Co Ltd HS355TD-AN4?

Key electrical performance ranks, roof area sizing, and NEC 690.7/690.8 design boundaries for Hansol Technics Co Ltd HS355TD-AN4 by Hansol Technics Co Ltd.

Rank #12,724 / 21,677

355.0 W STC · Higher Than 39.9%

355.0 W STC (-30.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #14,568

18.35% Aperture Efficiency

Power density 183.5 W/m2 (1.56 percentage points below 19.91% CEC median). PTC/STC ratio: 92.6% (rank #11,981).

NEC 690.7 Limit

11 Panels Max @ -10 C (600 V)

Cold Voc reaches 52.5 V at -10 C (577.5 V string) and 53.84 V at -20 C (11 max).

8 kW Reference Array

23 Panels = 8,165 W STC

Occupies 44.5 m2 (479 sq ft) producing 7,565 W PTC; NEC 690.8 OCPD floor is 15.05 A (20 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 47.8 * (1 + (-0.281/100) * (-10 - 25)) = 52.5 V | OCPD = 1.56 * 9.65 = 15.05 A

Inputs from CEC Modules.csv for Hansol Technics Co Ltd HS355TD-AN4: Voc=47.8 V, beta_Voc=-0.281%/C, Isc=9.65 A, STC=355.0 W, Area=1.935 m2.

Result: 11 panels max on 600 V (577.5 V); 23 panels for 8 kW (479 sq ft).

What Are the Published CEC Specifications for Hansol Technics Co Ltd HS355TD-AN4?

Laboratory test ratings recorded for Hansol Technics Co Ltd HS355TD-AN4 (Mono-c-Si) in the official California Energy Commission NREL SAM equipment catalog.

Official California Energy Commission (NREL SAM) test parameters for Hansol Technics Co Ltd HS355TD-AN4.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 355.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 328.9 W (92.6% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 47.8 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 9.65 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 39.2 V / 9.06 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.281 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 18.35% (1.935 m2) Array roof footprint density
Cell Count & Technology 72 cells (Mono-c-Si) Monofacial backsheet

How Many Hansol Technics Co Ltd HS355TD-AN4 Panels Build a 6 kW, 8 kW, or 10 kW Array?

Panel counts, roof square footage (479 sq ft at 8 kW), and estimated Year-1 electric bill offset for Hansol Technics Co Ltd HS355TD-AN4.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 17 6.04 kW 354 sq ft $1,512 $2,556
8 kW Class 23 8.16 kW 479 sq ft $2,042 $3,454
10 kW Class 29 10.29 kW 604 sq ft $2,575 $4,355

Which Sibling Wattage & Trim Variants Belong to This Hansol Technics Co Ltd Series?

Sibling wattage bins and frame colors grouped with Hansol Technics Co Ltd HS355TD-AN4 under Hansol Technics Co Ltd to prevent duplicate spec pages.

Sibling CEC listings grouped into the Hansol Technics Co Ltd HS355TD-AN4 wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
Hansol Technics Co Ltd HS350TD-AN4 350.0 W 324.1 W 47.4 V 38.8 V 18.09%
Hansol Technics Co Ltd HS355TD-AN4 355.0 W 328.9 W 47.8 V 39.2 V 18.35%
Hansol Technics Co Ltd HS360TD-AN4 360.0 W 333.6 W 48.2 V 39.6 V 18.61%

How Many Hansol Technics Co Ltd HS355TD-AN4 Modules Fit in a Cold-Weather String?

Cold-weather Voc escalation for Hansol Technics Co Ltd HS355TD-AN4 (beta_Voc -0.281%/C) across 600 V residential and 1,000 V commercial inverters.

Computed from Voc=47.8V and beta_Voc=-0.281%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 53.84 V 11 panels 592.2 V 18 panels
-10 C (14 F) 52.5 V 11 panels 577.5 V 19 panels
0 C (32 F) 51.16 V 11 panels 562.8 V 19 panels
25 C (77 F STC) 47.8 V 12 panels 573.6 V 20 panels

Which Cross-Brand Solar Modules Compare Closest to Hansol Technics Co Ltd HS355TD-AN4?

Closest cross-brand CEC competitors to Hansol Technics Co Ltd HS355TD-AN4 matched near 355.0 W STC and 47.8 V Voc, led by Bluesun Solar Energy Tech CoLtd BSM355P-72.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
Bluesun Solar Energy Tech CoLtd BSM355P-72
Bluesun Solar Energy Tech CoLtd
355.0 W Tie (0 W) 47.52 V 18.32% 91.6%
AXITEC AC-355M/156-72S
AXITEC
355.0 W Tie (0 W) 47.4 V 18.3% 91.5%
Boviet Solar Technology Co Ltd BVM6612P-355
Boviet Solar Technology Co Ltd
355.0 W Tie (0 W) 47.3 V 18.3% 92.6%
CertainTeed CT355M00-01
CertainTeed
355.0 W Tie (0 W) 47.3 V 19.61% 92.0%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for Hansol Technics Co Ltd HS355TD-AN4?

Evaluate Hansol Technics Co Ltd HS355TD-AN4 (355.0 W STC, 47.8 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), Hansol Technics Co Ltd HS355TD-AN4 reaches 53.84 V per panel—exceeding 11 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 23 panels for an 8 kW build require 479 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 23 panels (479 sq ft).
  • 2026 tax credit baseline: cash residential installs of Hansol Technics Co Ltd HS355TD-AN4 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

Hansol Technics Co Ltd HS355TD-AN4 8 kW Residential Fit

Needs 23 modules (479 sq ft) with a 20 A string OCPD, offsetting ~$2,042/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 11 panels (-10 C) or 11 panels (-20 C), or compare Bluesun Solar Energy Tech CoLtd BSM355P-72.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 328.9 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Hansol Technics Co Ltd HS355TD-AN4 by Hansol Technics Co Ltd grounded in CEC test data and NEC 690.7/690.8 limits.

How many Hansol Technics Co Ltd HS355TD-AN4 panels fit on a 600 V winter solar string?

At -10 C (14 F), Hansol Technics Co Ltd HS355TD-AN4 cold Voc rises from 47.8 V to 52.5 V (beta_Voc -0.281%/C), capping a 600 V string at 11 panels (577.5 V).

How much roof area does an 8 kW array of Hansol Technics Co Ltd HS355TD-AN4 need?

An 8 kW DC system uses 23 Hansol Technics Co Ltd HS355TD-AN4 modules (8,165 W STC / 7,565 W PTC), covering roughly 479 sq ft and saving ~$2,042/yr at 18.54 c/kWh.

How does Hansol Technics Co Ltd HS355TD-AN4 compare against Bluesun Solar Energy Tech CoLtd BSM355P-72?

Hansol Technics Co Ltd HS355TD-AN4 outputs 355.0 W STC (47.8 V Voc, rank #12,724 of 21,677), while Bluesun Solar Energy Tech CoLtd BSM355P-72 delivers 355.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.