Skip to main content
WireAndSun
Calculators
CEC PV Module

Hansol Technics Co Ltd HS345UD-AN1 {Wht} — CEC Solar Module Specifications

Manufacturer: Hansol Technics Co Ltd Registry: CEC Verified Engineering Specification

Hansol Technics Co Ltd HS345UD-AN1 {Wht} is a 345.0 W STC (315.3 W PTC) Mono-c-Si solar module ranking #13,309 of 21,677 CEC listings (below all-CEC median; higher than 37.4% of peers). It delivers 17.78% efficiency, 46.4 V Voc at 25 C, and 50.96 V cold Voc at -10 C (11 panels max per 600 V string).

STC Wattage
345.0 W
PTC Wattage
315.3 W
Voc @ 25C
46.4 V
Efficiency
17.78%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does Hansol Technics Co Ltd HS345UD-AN1 {Wht} Compare Against Peer CEC Listings?

How Hansol Technics Co Ltd Hansol Technics Co Ltd HS345UD-AN1 {Wht} handles rooftop heat (315.3 W PTC), 8 kW sizing, and cold winter string voltage.

For NEC string engineering, Hansol Technics Co Ltd HS345UD-AN1 {Wht} exhibits 9.55 A short-circuit current, requiring a 14.9 A (156%) conductor rating and 15 A OCPD under NEC 690.8. Ranked #13,309 of 21,677 (65.0 W below the 410.0 W Mono-c-Si median), this compact residential or specialty off-grid module covers 46.6 m2 for an 8 kW system (29 panels for 10 kW). Mid-range 46.4 V open-circuit voltage allows up to 11 panels per 600 V string at 14 F.

Where Does Hansol Technics Co Ltd HS345UD-AN1 {Wht} Fall Across Listed CEC Models?

Where Hansol Technics Co Ltd HS345UD-AN1 {Wht} (345.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where Hansol Technics Co Ltd HS345UD-AN1 {Wht} (345.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCHansol Technics Co: 345.0 W

What Dataset Percentiles Define Hansol Technics Co Ltd HS345UD-AN1 {Wht}?

Percentile placement of Hansol Technics Co Ltd HS345UD-AN1 {Wht} across power density (177.8 W/m2), thermal retention, and nameplate STC wattage.

Hansol Technics Co Ltd HS345UD-AN1 {Wht} Engineering BenchmarksPercentile comparison of Hansol Technics Co Ltd HS345UD-AN1 {Wht} wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage345.0 WPTC/STC Retention91.4%Module Efficiency17.78%

What Do the Dataset Ranks Show for Hansol Technics Co Ltd HS345UD-AN1 {Wht}?

Four critical engineering numbers homeowners and solar installers check first when reviewing Hansol Technics Co Ltd HS345UD-AN1 {Wht} specifications.

Rank #13,309 / 21,677

345.0 W STC · Higher Than 37.4%

345.0 W STC (-40.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #15,390

17.78% Aperture Efficiency

Power density 177.8 W/m2 (2.13 percentage points below 19.91% CEC median). PTC/STC ratio: 91.4% (rank #15,834).

NEC 690.7 Limit

11 Panels Max @ -10 C (600 V)

Cold Voc reaches 50.96 V at -10 C (560.6 V string) and 52.27 V at -20 C (11 max).

8 kW Reference Array

24 Panels = 8,280 W STC

Occupies 46.6 m2 (501 sq ft) producing 7,567 W PTC; NEC 690.8 OCPD floor is 14.9 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 46.4 * (1 + (-0.281/100) * (-10 - 25)) = 50.96 V | OCPD = 1.56 * 9.55 = 14.9 A

Inputs from CEC Modules.csv for Hansol Technics Co Ltd HS345UD-AN1 {Wht}: Voc=46.4 V, beta_Voc=-0.281%/C, Isc=9.55 A, STC=345.0 W, Area=1.94 m2.

Result: 11 panels max on 600 V (560.6 V); 24 panels for 8 kW (501 sq ft).

What Are the Published CEC Specifications for Hansol Technics Co Ltd HS345UD-AN1 {Wht}?

Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for Hansol Technics Co Ltd HS345UD-AN1 {Wht}.

Official California Energy Commission (NREL SAM) test parameters for Hansol Technics Co Ltd HS345UD-AN1 {Wht}.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 345.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 315.3 W (91.4% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 46.4 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 9.55 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 38.6 V / 8.94 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.281 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 17.78% (1.94 m2) Array roof footprint density
Cell Count & Technology 72 cells (Mono-c-Si) Monofacial backsheet

How Many Hansol Technics Co Ltd HS345UD-AN1 {Wht} Panels Build a 6 kW, 8 kW, or 10 kW Array?

Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using Hansol Technics Co Ltd HS345UD-AN1 {Wht} (345.0 W).

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 18 6.21 kW 376 sq ft $1,554 $2,628
8 kW Class 24 8.28 kW 501 sq ft $2,072 $3,504
10 kW Class 29 10.01 kW 606 sq ft $2,505 $4,236

Which Sibling Wattage & Trim Variants Belong to This Hansol Technics Co Ltd Series?

All closely matched Hansol Technics Co Ltd wattages and cosmetic trims sharing the Hansol Technics Co Ltd HS345UD-AN1 {Wht} architecture.

Sibling CEC listings grouped into the Hansol Technics Co Ltd HS345UD-AN1 {Wht} wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
Hansol Technics Co Ltd HS340UD-AN1 {Wht} 340.0 W 310.6 W 46.1 V 38.3 V 17.58%
Hansol Technics Co Ltd HS345UD-AN1 {Wht} 345.0 W 315.3 W 46.4 V 38.6 V 17.78%

How Many Hansol Technics Co Ltd HS345UD-AN1 {Wht} Modules Fit in a Cold-Weather String?

Maximum series module counts for Hansol Technics Co Ltd HS345UD-AN1 {Wht} from 25 C down to -20 C (-4 F) under NEC 690.7.

Computed from Voc=46.4V and beta_Voc=-0.281%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 52.27 V 11 panels 575.0 V 19 panels
-10 C (14 F) 50.96 V 11 panels 560.6 V 19 panels
0 C (32 F) 49.66 V 12 panels 595.9 V 20 panels
25 C (77 F STC) 46.4 V 12 panels 556.8 V 21 panels

Which Cross-Brand Solar Modules Compare Closest to Hansol Technics Co Ltd HS345UD-AN1 {Wht}?

Alternative CEC solar modules from competing brands near Hansol Technics Co Ltd HS345UD-AN1 {Wht} (345.0 W), including GCL System Integration Technology Co Ltd GCL-M6/72345.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
GCL System Integration Technology Co Ltd GCL-M6/72345
GCL System Integration Technology Co Ltd
345.0 W Tie (0 W) 46.8 V 17.78% 90.5%
GCL System Integration Technology Co Ltd GCL-P3/72H345
GCL System Integration Technology Co Ltd
345.0 W Tie (0 W) 46.88 V 17.16% 93.1%
AXITEC AC-345M/156-72S
AXITEC
345.0 W Tie (0 W) 47.0 V 17.78% 91.4%
GCL System Integration Technology Co Ltd GCL-P6/72345
GCL System Integration Technology Co Ltd
345.0 W Tie (0 W) 47.3 V 17.78% 91.6%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for Hansol Technics Co Ltd HS345UD-AN1 {Wht}?

Evaluate Hansol Technics Co Ltd HS345UD-AN1 {Wht} (345.0 W STC, 46.4 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), Hansol Technics Co Ltd HS345UD-AN1 {Wht} reaches 52.27 V per panel—exceeding 11 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 24 panels for an 8 kW build require 501 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 24 panels (501 sq ft).
  • 2026 tax credit baseline: cash residential installs of Hansol Technics Co Ltd HS345UD-AN1 {Wht} carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

Hansol Technics Co Ltd HS345UD-AN1 {Wht} 8 kW Residential Fit

Needs 24 modules (501 sq ft) with a 15 A string OCPD, offsetting ~$2,072/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 11 panels (-10 C) or 11 panels (-20 C), or compare GCL System Integration Technology Co Ltd GCL-M6/72345.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 315.3 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Hansol Technics Co Ltd HS345UD-AN1 {Wht} by Hansol Technics Co Ltd grounded in CEC test data and NEC 690.7/690.8 limits.

Why is Hansol Technics Co Ltd HS345UD-AN1 {Wht} PTC wattage (315.3 W) lower than STC (345.0 W)?

Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 315.3 W PTC (91.4% retention) across Hansol Technics Co Ltd HS345UD-AN1 {Wht}'s 1.94 m2 aperture.

Who should skip Hansol Technics Co Ltd HS345UD-AN1 {Wht} on a complex residential roof?

Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 24 Hansol Technics Co Ltd HS345UD-AN1 {Wht} panels (501 sq ft) leave unusable roof gaps vs. GCL System Integration Technology Co Ltd GCL-M6/72345.

What is the 1,000 V commercial string limit for Hansol Technics Co Ltd HS345UD-AN1 {Wht}?

On 1,000 V commercial inverters at -10 C (50.96 V cold Voc), Hansol Technics Co Ltd HS345UD-AN1 {Wht} fits up to 19 panels per series string.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.