Hansol Technics Co Ltd HS345UD-AN1 {Blk} is a 345.0 W STC (318.1 W PTC) Mono-c-Si solar module ranking #13,309 of 21,677 CEC listings (below all-CEC median; higher than 37.4% of peers). It delivers 17.97% efficiency, 46.4 V Voc at 25 C, and 50.96 V cold Voc at -10 C (11 panels max per 600 V string).
- STC Wattage
- 345.0 W
- PTC Wattage
- 318.1 W
- Voc @ 25C
- 46.4 V
- Efficiency
- 17.97%
How Does Hansol Technics Co Ltd HS345UD-AN1 {Blk} Compare Against Peer CEC Listings?
Solar engineering breakdown for Hansol Technics Co Ltd HS345UD-AN1 {Blk}: PTC thermal retention, roof footprint, and cold Voc string bounds.
Measured at 345.0 W STC and 318.1 W PTC, Hansol Technics Co Ltd HS345UD-AN1 {Blk} sits -40.0 W vs all-CEC median (below all-CEC median; higher than 37.4% of peers) among 21,677 listed modules. Power density reaches 179.7 W/m2 (1.94 percentage points below 19.91% CEC median). Mid-range 46.4 V open-circuit voltage allows up to 11 panels per 600 V string at 14 F, whereas 1,000 V commercial inverters handle up to 19 panels in series. Alternative peer GCL System Integration Technology Co Ltd GCL-M6/72345 rates 345.0 W.
Where Does Hansol Technics Co Ltd HS345UD-AN1 {Blk} Fall Across Listed CEC Models?
Distribution marker showing Hansol Technics Co Ltd HS345UD-AN1 {Blk} (345.0 W) relative to the 385.0 W all-CEC solar panel median.
What Dataset Percentiles Define Hansol Technics Co Ltd HS345UD-AN1 {Blk}?
Dataset percentiles tracking Hansol Technics Co Ltd HS345UD-AN1 {Blk} power output, thermal retention ratio, and aperture efficiency against 21,677 models.
What Do the Dataset Ranks Show for Hansol Technics Co Ltd HS345UD-AN1 {Blk}?
Benchmark highlights for Hansol Technics Co Ltd HS345UD-AN1 {Blk} covering STC output, efficiency, 8 kW footprint, and OCPD breaker size.
345.0 W STC · Higher Than 37.4%
345.0 W STC (-40.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.
17.97% Aperture Efficiency
Power density 179.7 W/m2 (1.94 percentage points below 19.91% CEC median). PTC/STC ratio: 92.2% (rank #13,542).
11 Panels Max @ -10 C (600 V)
Cold Voc reaches 50.96 V at -10 C (560.6 V string) and 52.27 V at -20 C (11 max).
24 Panels = 8,280 W STC
Occupies 46.1 m2 (496 sq ft) producing 7,634 W PTC; NEC 690.8 OCPD floor is 14.9 A (15 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 46.4 * (1 + (-0.281/100) * (-10 - 25)) = 50.96 V | OCPD = 1.56 * 9.55 = 14.9 A
Inputs from CEC Modules.csv for Hansol Technics Co Ltd HS345UD-AN1 {Blk}: Voc=46.4 V, beta_Voc=-0.281%/C, Isc=9.55 A, STC=345.0 W, Area=1.92 m2.
Result: 11 panels max on 600 V (560.6 V); 24 panels for 8 kW (496 sq ft).
What Are the Published CEC Specifications for Hansol Technics Co Ltd HS345UD-AN1 {Blk}?
Official CEC datasheet figures for Hansol Technics Co Ltd HS345UD-AN1 {Blk} (Mono-c-Si) used in utility interconnection and permit reviews.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 345.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 318.1 W (92.2% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 46.4 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 9.55 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 38.6 V / 8.94 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.281 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 17.97% (1.92 m2) | Array roof footprint density |
| Cell Count & Technology | 72 cells (Mono-c-Si) | Monofacial backsheet |
How Many Hansol Technics Co Ltd HS345UD-AN1 {Blk} Panels Build a 6 kW, 8 kW, or 10 kW Array?
How many Hansol Technics Co Ltd HS345UD-AN1 {Blk} modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 18 | 6.21 kW | 372 sq ft | $1,554 | $2,628 |
| 8 kW Class | 24 | 8.28 kW | 496 sq ft | $2,072 | $3,504 |
| 10 kW Class | 29 | 10.01 kW | 599 sq ft | $2,505 | $4,236 |
How Many Hansol Technics Co Ltd HS345UD-AN1 {Blk} Modules Fit in a Cold-Weather String?
NEC 690.7(A) winter string table preventing overvoltage trips on Hansol Technics Co Ltd HS345UD-AN1 {Blk} (50.96 V at 14 F).
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 52.27 V | 11 panels | 575.0 V | 19 panels |
| -10 C (14 F) | 50.96 V | 11 panels | 560.6 V | 19 panels |
| 0 C (32 F) | 49.66 V | 12 panels | 595.9 V | 20 panels |
| 25 C (77 F STC) | 46.4 V | 12 panels | 556.8 V | 21 panels |
Which Cross-Brand Solar Modules Compare Closest to Hansol Technics Co Ltd HS345UD-AN1 {Blk}?
Competing CEC solar panels closest to Hansol Technics Co Ltd HS345UD-AN1 {Blk} in nameplate wattage and Voc, starting with GCL System Integration Technology Co Ltd GCL-M6/72345.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| GCL System Integration Technology Co Ltd GCL-M6/72345 GCL System Integration Technology Co Ltd |
345.0 W | Tie (0 W) | 46.8 V | 17.78% | 90.5% |
| GCL System Integration Technology Co Ltd GCL-P3/72H345 GCL System Integration Technology Co Ltd |
345.0 W | Tie (0 W) | 46.88 V | 17.16% | 93.1% |
| AXITEC AC-345M/156-72S AXITEC |
345.0 W | Tie (0 W) | 47.0 V | 17.78% | 91.4% |
| GCL System Integration Technology Co Ltd GCL-P6/72345 GCL System Integration Technology Co Ltd |
345.0 W | Tie (0 W) | 47.3 V | 17.78% | 91.6% |
What Are the Design Limits and Best-Fit Uses for Hansol Technics Co Ltd HS345UD-AN1 {Blk}?
Evaluate Hansol Technics Co Ltd HS345UD-AN1 {Blk} (345.0 W STC, 46.4 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), Hansol Technics Co Ltd HS345UD-AN1 {Blk} reaches 52.27 V per panel—exceeding 11 panels in series voids 600 V inverter warranties.
- Footprint constraint: 24 panels for an 8 kW build require 496 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 24 panels (496 sq ft).
- 2026 tax credit baseline: cash residential installs of Hansol Technics Co Ltd HS345UD-AN1 {Blk} carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
Hansol Technics Co Ltd HS345UD-AN1 {Blk} 8 kW Residential Fit
Needs 24 modules (496 sq ft) with a 15 A string OCPD, offsetting ~$2,072/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 11 panels (-10 C) or 11 panels (-20 C), or compare GCL System Integration Technology Co Ltd GCL-M6/72345.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 318.1 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for Hansol Technics Co Ltd HS345UD-AN1 {Blk} by Hansol Technics Co Ltd grounded in CEC test data and NEC 690.7/690.8 limits.
How many Hansol Technics Co Ltd HS345UD-AN1 {Blk} panels fit on a 600 V winter solar string?
At -10 C (14 F), Hansol Technics Co Ltd HS345UD-AN1 {Blk} cold Voc rises from 46.4 V to 50.96 V (beta_Voc -0.281%/C), capping a 600 V string at 11 panels (560.6 V).
How much roof area does an 8 kW array of Hansol Technics Co Ltd HS345UD-AN1 {Blk} need?
An 8 kW DC system uses 24 Hansol Technics Co Ltd HS345UD-AN1 {Blk} modules (8,280 W STC / 7,634 W PTC), covering roughly 496 sq ft and saving ~$2,072/yr at 18.54 c/kWh.
How does Hansol Technics Co Ltd HS345UD-AN1 {Blk} compare against GCL System Integration Technology Co Ltd GCL-M6/72345?
Hansol Technics Co Ltd HS345UD-AN1 {Blk} outputs 345.0 W STC (46.4 V Voc, rank #13,309 of 21,677), while GCL System Integration Technology Co Ltd GCL-M6/72345 delivers 345.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)