Hansol Technics Co Ltd HS340TD-AN4 is a 340.0 W STC (314.6 W PTC) Mono-c-Si solar module ranking #13,575 of 21,677 CEC listings (below all-CEC median; higher than 36.1% of peers). It delivers 17.58% efficiency, 46.6 V Voc at 25 C, and 51.18 V cold Voc at -10 C (11 panels max per 600 V string).
- STC Wattage
- 340.0 W
- PTC Wattage
- 314.6 W
- Voc @ 25C
- 46.6 V
- Efficiency
- 17.58%
How Does Hansol Technics Co Ltd HS340TD-AN4 Compare Against Peer CEC Listings?
CEC rank, roof space requirements, and NEC 690.7/690.8 limits for Hansol Technics Co Ltd HS340TD-AN4 (Mono-c-Si) residential solar systems.
Homeowners evaluating Hansol Technics Co Ltd HS340TD-AN4 need 18 panels for 6 kW or 24 panels (500 sq ft) for an 8 kW array—useful on tight dormer roofs or battery cabins, though 8 kW requires 24 panels (500 sq ft). Under NEC 690.7(A), beta_Voc (-0.281%/C) pushes open-circuit voltage to 51.18 V at 14 F and 52.49 V at -4 F. Monofacial backsheet sealing targets flush dark shingle rooftop mounts.
Where Does Hansol Technics Co Ltd HS340TD-AN4 Fall Across Listed CEC Models?
Comparison of Hansol Technics Co Ltd HS340TD-AN4 (340.0 W STC) against all 21,677 California Energy Commission certified photovoltaic modules.
What Dataset Percentiles Define Hansol Technics Co Ltd HS340TD-AN4?
Relative ranking of Hansol Technics Co Ltd HS340TD-AN4 across nameplate watts, 92.5% PTC thermal ratio, and module aperture efficiency.
What Do the Dataset Ranks Show for Hansol Technics Co Ltd HS340TD-AN4?
Summary of Hansol Technics Co Ltd HS340TD-AN4 output rank, 8 kW array size (24 panels), efficiency rating, and 600 V string limit.
340.0 W STC · Higher Than 36.1%
340.0 W STC (-45.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.
17.58% Aperture Efficiency
Power density 175.7 W/m2 (2.33 percentage points below 19.91% CEC median). PTC/STC ratio: 92.5% (rank #12,531).
11 Panels Max @ -10 C (600 V)
Cold Voc reaches 51.18 V at -10 C (563.0 V string) and 52.49 V at -20 C (11 max).
24 Panels = 8,160 W STC
Occupies 46.4 m2 (500 sq ft) producing 7,550 W PTC; NEC 690.8 OCPD floor is 14.88 A (15 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 46.6 * (1 + (-0.281/100) * (-10 - 25)) = 51.18 V | OCPD = 1.56 * 9.54 = 14.88 A
Inputs from CEC Modules.csv for Hansol Technics Co Ltd HS340TD-AN4: Voc=46.6 V, beta_Voc=-0.281%/C, Isc=9.54 A, STC=340.0 W, Area=1.935 m2.
Result: 11 panels max on 600 V (563.0 V); 24 panels for 8 kW (500 sq ft).
What Are the Published CEC Specifications for Hansol Technics Co Ltd HS340TD-AN4?
Complete CEC test sheet for Hansol Technics Co Ltd HS340TD-AN4 including Isc (9.54 A), Voc (46.6 V), and thermal temperature coefficients.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 340.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 314.6 W (92.5% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 46.6 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 9.54 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 38.0 V / 8.95 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.281 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 17.58% (1.935 m2) | Array roof footprint density |
| Cell Count & Technology | 72 cells (Mono-c-Si) | Monofacial backsheet |
How Many Hansol Technics Co Ltd HS340TD-AN4 Panels Build a 6 kW, 8 kW, or 10 kW Array?
Residential array count and annual electric bill savings at 18.54 c/kWh US avg vs. California tariffs using Hansol Technics Co Ltd HS340TD-AN4.
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 18 | 6.12 kW | 375 sq ft | $1,532 | $2,590 |
| 8 kW Class | 24 | 8.16 kW | 500 sq ft | $2,042 | $3,454 |
| 10 kW Class | 30 | 10.2 kW | 625 sq ft | $2,553 | $4,317 |
Which Sibling Wattage & Trim Variants Belong to This Hansol Technics Co Ltd Series?
Related Hansol Technics Co Ltd power steps and black/silver trims consolidated into this Hansol Technics Co Ltd HS340TD-AN4 series guide.
| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| Hansol Technics Co Ltd HS330TD-AN4 | 330.0 W | 305.2 W | 45.8 V | 37.2 V | 17.06% |
| Hansol Technics Co Ltd HS335TD-AN4 | 335.0 W | 309.9 W | 46.2 V | 37.6 V | 17.32% |
| Hansol Technics Co Ltd HS340TD-AN4 | 340.0 W | 314.6 W | 46.6 V | 38.0 V | 17.58% |
| Hansol Technics Co Ltd HS345TD-AN4 | 345.0 W | 319.4 W | 47.0 V | 38.4 V | 17.83% |
How Many Hansol Technics Co Ltd HS340TD-AN4 Modules Fit in a Cold-Weather String?
Verify freezing-morning voltage rise for Hansol Technics Co Ltd HS340TD-AN4 (46.6 V STC) before wiring 600 V or 1,000 V strings.
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 52.49 V | 11 panels | 577.4 V | 19 panels |
| -10 C (14 F) | 51.18 V | 11 panels | 563.0 V | 19 panels |
| 0 C (32 F) | 49.87 V | 12 panels | 598.4 V | 20 panels |
| 25 C (77 F STC) | 46.6 V | 12 panels | 559.2 V | 21 panels |
Which Cross-Brand Solar Modules Compare Closest to Hansol Technics Co Ltd HS340TD-AN4?
Four comparable CEC modules such as GCL System Integration Technology Co Ltd GCL-M6/72340 (340.0 W) for side-by-side solar quote checks.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| GCL System Integration Technology Co Ltd GCL-M6/72340 GCL System Integration Technology Co Ltd |
340.0 W | Tie (0 W) | 46.6 V | 17.53% | 90.5% |
| GCL System Integration Technology Co Ltd GCL-M6/72H340 GCL System Integration Technology Co Ltd |
340.0 W | Tie (0 W) | 46.6 V | 17.53% | 91.4% |
| GCL System Integration Technology Co Ltd GCL-P6/72340 GCL System Integration Technology Co Ltd |
340.0 W | Tie (0 W) | 46.6 V | 17.53% | 91.5% |
| GCL System Integration Technology Co Ltd GCL-P6/72H340 GCL System Integration Technology Co Ltd |
340.0 W | Tie (0 W) | 46.6 V | 17.53% | 91.7% |
What Are the Design Limits and Best-Fit Uses for Hansol Technics Co Ltd HS340TD-AN4?
Evaluate Hansol Technics Co Ltd HS340TD-AN4 (340.0 W STC, 46.6 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), Hansol Technics Co Ltd HS340TD-AN4 reaches 52.49 V per panel—exceeding 11 panels in series voids 600 V inverter warranties.
- Footprint constraint: 24 panels for an 8 kW build require 500 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 24 panels (500 sq ft).
- 2026 tax credit baseline: cash residential installs of Hansol Technics Co Ltd HS340TD-AN4 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
Hansol Technics Co Ltd HS340TD-AN4 8 kW Residential Fit
Needs 24 modules (500 sq ft) with a 15 A string OCPD, offsetting ~$2,042/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 11 panels (-10 C) or 11 panels (-20 C), or compare GCL System Integration Technology Co Ltd GCL-M6/72340.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 314.6 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for Hansol Technics Co Ltd HS340TD-AN4 by Hansol Technics Co Ltd grounded in CEC test data and NEC 690.7/690.8 limits.
Why is Hansol Technics Co Ltd HS340TD-AN4 PTC wattage (314.6 W) lower than STC (340.0 W)?
Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 314.6 W PTC (92.5% retention) across Hansol Technics Co Ltd HS340TD-AN4's 1.935 m2 aperture.
Who should skip Hansol Technics Co Ltd HS340TD-AN4 on a complex residential roof?
Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 24 Hansol Technics Co Ltd HS340TD-AN4 panels (500 sq ft) leave unusable roof gaps vs. GCL System Integration Technology Co Ltd GCL-M6/72340.
What is the 1,000 V commercial string limit for Hansol Technics Co Ltd HS340TD-AN4?
On 1,000 V commercial inverters at -10 C (51.18 V cold Voc), Hansol Technics Co Ltd HS340TD-AN4 fits up to 19 panels per series string.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)