Skip to main content
WireAndSun
Calculators
CEC PV Module

Hansol Technics Co Ltd HS340TD-AN4 — CEC Solar Module Specifications

Manufacturer: Hansol Technics Co Ltd Registry: CEC Verified Engineering Specification

Hansol Technics Co Ltd HS340TD-AN4 is a 340.0 W STC (314.6 W PTC) Mono-c-Si solar module ranking #13,575 of 21,677 CEC listings (below all-CEC median; higher than 36.1% of peers). It delivers 17.58% efficiency, 46.6 V Voc at 25 C, and 51.18 V cold Voc at -10 C (11 panels max per 600 V string).

STC Wattage
340.0 W
PTC Wattage
314.6 W
Voc @ 25C
46.6 V
Efficiency
17.58%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does Hansol Technics Co Ltd HS340TD-AN4 Compare Against Peer CEC Listings?

CEC rank, roof space requirements, and NEC 690.7/690.8 limits for Hansol Technics Co Ltd HS340TD-AN4 (Mono-c-Si) residential solar systems.

Homeowners evaluating Hansol Technics Co Ltd HS340TD-AN4 need 18 panels for 6 kW or 24 panels (500 sq ft) for an 8 kW array—useful on tight dormer roofs or battery cabins, though 8 kW requires 24 panels (500 sq ft). Under NEC 690.7(A), beta_Voc (-0.281%/C) pushes open-circuit voltage to 51.18 V at 14 F and 52.49 V at -4 F. Monofacial backsheet sealing targets flush dark shingle rooftop mounts.

Where Does Hansol Technics Co Ltd HS340TD-AN4 Fall Across Listed CEC Models?

Comparison of Hansol Technics Co Ltd HS340TD-AN4 (340.0 W STC) against all 21,677 California Energy Commission certified photovoltaic modules.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where Hansol Technics Co Ltd HS340TD-AN4 (340.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCHansol Technics Co: 340.0 W

What Dataset Percentiles Define Hansol Technics Co Ltd HS340TD-AN4?

Relative ranking of Hansol Technics Co Ltd HS340TD-AN4 across nameplate watts, 92.5% PTC thermal ratio, and module aperture efficiency.

Hansol Technics Co Ltd HS340TD-AN4 Engineering BenchmarksPercentile comparison of Hansol Technics Co Ltd HS340TD-AN4 wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage340.0 WPTC/STC Retention92.5%Module Efficiency17.58%

What Do the Dataset Ranks Show for Hansol Technics Co Ltd HS340TD-AN4?

Summary of Hansol Technics Co Ltd HS340TD-AN4 output rank, 8 kW array size (24 panels), efficiency rating, and 600 V string limit.

Rank #13,575 / 21,677

340.0 W STC · Higher Than 36.1%

340.0 W STC (-45.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #15,678

17.58% Aperture Efficiency

Power density 175.7 W/m2 (2.33 percentage points below 19.91% CEC median). PTC/STC ratio: 92.5% (rank #12,531).

NEC 690.7 Limit

11 Panels Max @ -10 C (600 V)

Cold Voc reaches 51.18 V at -10 C (563.0 V string) and 52.49 V at -20 C (11 max).

8 kW Reference Array

24 Panels = 8,160 W STC

Occupies 46.4 m2 (500 sq ft) producing 7,550 W PTC; NEC 690.8 OCPD floor is 14.88 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 46.6 * (1 + (-0.281/100) * (-10 - 25)) = 51.18 V | OCPD = 1.56 * 9.54 = 14.88 A

Inputs from CEC Modules.csv for Hansol Technics Co Ltd HS340TD-AN4: Voc=46.6 V, beta_Voc=-0.281%/C, Isc=9.54 A, STC=340.0 W, Area=1.935 m2.

Result: 11 panels max on 600 V (563.0 V); 24 panels for 8 kW (500 sq ft).

What Are the Published CEC Specifications for Hansol Technics Co Ltd HS340TD-AN4?

Complete CEC test sheet for Hansol Technics Co Ltd HS340TD-AN4 including Isc (9.54 A), Voc (46.6 V), and thermal temperature coefficients.

Official California Energy Commission (NREL SAM) test parameters for Hansol Technics Co Ltd HS340TD-AN4.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 340.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 314.6 W (92.5% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 46.6 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 9.54 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 38.0 V / 8.95 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.281 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 17.58% (1.935 m2) Array roof footprint density
Cell Count & Technology 72 cells (Mono-c-Si) Monofacial backsheet

How Many Hansol Technics Co Ltd HS340TD-AN4 Panels Build a 6 kW, 8 kW, or 10 kW Array?

Residential array count and annual electric bill savings at 18.54 c/kWh US avg vs. California tariffs using Hansol Technics Co Ltd HS340TD-AN4.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 18 6.12 kW 375 sq ft $1,532 $2,590
8 kW Class 24 8.16 kW 500 sq ft $2,042 $3,454
10 kW Class 30 10.2 kW 625 sq ft $2,553 $4,317

Which Sibling Wattage & Trim Variants Belong to This Hansol Technics Co Ltd Series?

Related Hansol Technics Co Ltd power steps and black/silver trims consolidated into this Hansol Technics Co Ltd HS340TD-AN4 series guide.

Sibling CEC listings grouped into the Hansol Technics Co Ltd HS340TD-AN4 wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
Hansol Technics Co Ltd HS330TD-AN4 330.0 W 305.2 W 45.8 V 37.2 V 17.06%
Hansol Technics Co Ltd HS335TD-AN4 335.0 W 309.9 W 46.2 V 37.6 V 17.32%
Hansol Technics Co Ltd HS340TD-AN4 340.0 W 314.6 W 46.6 V 38.0 V 17.58%
Hansol Technics Co Ltd HS345TD-AN4 345.0 W 319.4 W 47.0 V 38.4 V 17.83%

How Many Hansol Technics Co Ltd HS340TD-AN4 Modules Fit in a Cold-Weather String?

Verify freezing-morning voltage rise for Hansol Technics Co Ltd HS340TD-AN4 (46.6 V STC) before wiring 600 V or 1,000 V strings.

Computed from Voc=46.6V and beta_Voc=-0.281%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 52.49 V 11 panels 577.4 V 19 panels
-10 C (14 F) 51.18 V 11 panels 563.0 V 19 panels
0 C (32 F) 49.87 V 12 panels 598.4 V 20 panels
25 C (77 F STC) 46.6 V 12 panels 559.2 V 21 panels

Which Cross-Brand Solar Modules Compare Closest to Hansol Technics Co Ltd HS340TD-AN4?

Four comparable CEC modules such as GCL System Integration Technology Co Ltd GCL-M6/72340 (340.0 W) for side-by-side solar quote checks.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
GCL System Integration Technology Co Ltd GCL-M6/72340
GCL System Integration Technology Co Ltd
340.0 W Tie (0 W) 46.6 V 17.53% 90.5%
GCL System Integration Technology Co Ltd GCL-M6/72H340
GCL System Integration Technology Co Ltd
340.0 W Tie (0 W) 46.6 V 17.53% 91.4%
GCL System Integration Technology Co Ltd GCL-P6/72340
GCL System Integration Technology Co Ltd
340.0 W Tie (0 W) 46.6 V 17.53% 91.5%
GCL System Integration Technology Co Ltd GCL-P6/72H340
GCL System Integration Technology Co Ltd
340.0 W Tie (0 W) 46.6 V 17.53% 91.7%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for Hansol Technics Co Ltd HS340TD-AN4?

Evaluate Hansol Technics Co Ltd HS340TD-AN4 (340.0 W STC, 46.6 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), Hansol Technics Co Ltd HS340TD-AN4 reaches 52.49 V per panel—exceeding 11 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 24 panels for an 8 kW build require 500 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 24 panels (500 sq ft).
  • 2026 tax credit baseline: cash residential installs of Hansol Technics Co Ltd HS340TD-AN4 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

Hansol Technics Co Ltd HS340TD-AN4 8 kW Residential Fit

Needs 24 modules (500 sq ft) with a 15 A string OCPD, offsetting ~$2,042/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 11 panels (-10 C) or 11 panels (-20 C), or compare GCL System Integration Technology Co Ltd GCL-M6/72340.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 314.6 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Hansol Technics Co Ltd HS340TD-AN4 by Hansol Technics Co Ltd grounded in CEC test data and NEC 690.7/690.8 limits.

Why is Hansol Technics Co Ltd HS340TD-AN4 PTC wattage (314.6 W) lower than STC (340.0 W)?

Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 314.6 W PTC (92.5% retention) across Hansol Technics Co Ltd HS340TD-AN4's 1.935 m2 aperture.

Who should skip Hansol Technics Co Ltd HS340TD-AN4 on a complex residential roof?

Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 24 Hansol Technics Co Ltd HS340TD-AN4 panels (500 sq ft) leave unusable roof gaps vs. GCL System Integration Technology Co Ltd GCL-M6/72340.

What is the 1,000 V commercial string limit for Hansol Technics Co Ltd HS340TD-AN4?

On 1,000 V commercial inverters at -10 C (51.18 V cold Voc), Hansol Technics Co Ltd HS340TD-AN4 fits up to 19 panels per series string.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.