Skip to main content
WireAndSun
Calculators
CEC PV Module

Hansol Technics Co Ltd HS330UB-JH2 {Wht} — CEC Solar Module Specifications

Manufacturer: Hansol Technics Co Ltd Registry: CEC Verified Engineering Specification

Hansol Technics Co Ltd HS330UB-JH2 {Wht} is a 330.0 W STC (309.3 W PTC) Mono-c-Si solar module ranking #14,165 of 21,677 CEC listings (below all-CEC median; higher than 32.9% of peers). It delivers 20.48% efficiency, 41.0 V Voc at 25 C, and 45.02 V cold Voc at -10 C (13 panels max per 600 V string).

STC Wattage
330.0 W
PTC Wattage
309.3 W
Voc @ 25C
41.0 V
Efficiency
20.48%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does Hansol Technics Co Ltd HS330UB-JH2 {Wht} Compare Against Peer CEC Listings?

How Hansol Technics Co Ltd Hansol Technics Co Ltd HS330UB-JH2 {Wht} handles rooftop heat (309.3 W PTC), 8 kW sizing, and cold winter string voltage.

Hansol Technics Co Ltd builds the Hansol Technics Co Ltd HS330UB-JH2 {Wht} (Mono-c-Si) as a compact residential or specialty off-grid module delivering 204.8 W/m2 (0.57 percentage points above 19.91% CEC median). Compared against CSI Solar Co Ltd CS3K-330MS (330.0 W), this model holds strong 93.7% PTC-to-STC heat retention (#6,162 of 21,677). Mid-range 41.0 V open-circuit voltage allows up to 13 panels per 600 V string at 14 F, while NEC 690.8 sets a 15.74 A overcurrent floor served by a 20 A breaker.

Where Does Hansol Technics Co Ltd HS330UB-JH2 {Wht} Fall Across Listed CEC Models?

Where Hansol Technics Co Ltd HS330UB-JH2 {Wht} (330.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where Hansol Technics Co Ltd HS330UB-JH2 {Wht} (330.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCHansol Technics Co: 330.0 W

What Dataset Percentiles Define Hansol Technics Co Ltd HS330UB-JH2 {Wht}?

Percentile placement of Hansol Technics Co Ltd HS330UB-JH2 {Wht} across power density (204.8 W/m2), thermal retention, and nameplate STC wattage.

Hansol Technics Co Ltd HS330UB-JH2 {Wht} Engineering BenchmarksPercentile comparison of Hansol Technics Co Ltd HS330UB-JH2 {Wht} wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage330.0 WPTC/STC Retention93.7%Module Efficiency20.48%

What Do the Dataset Ranks Show for Hansol Technics Co Ltd HS330UB-JH2 {Wht}?

Four critical engineering numbers homeowners and solar installers check first when reviewing Hansol Technics Co Ltd HS330UB-JH2 {Wht} specifications.

Rank #14,165 / 21,677

330.0 W STC · Higher Than 32.9%

330.0 W STC (-55.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #8,682

20.48% Aperture Efficiency

Power density 204.8 W/m2 (0.57 percentage points above 19.91% CEC median). PTC/STC ratio: 93.7% (rank #6,162).

NEC 690.7 Limit

13 Panels Max @ -10 C (600 V)

Cold Voc reaches 45.02 V at -10 C (585.3 V string) and 46.17 V at -20 C (12 max).

8 kW Reference Array

25 Panels = 8,250 W STC

Occupies 40.3 m2 (434 sq ft) producing 7,732 W PTC; NEC 690.8 OCPD floor is 15.74 A (20 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 41.0 * (1 + (-0.28/100) * (-10 - 25)) = 45.02 V | OCPD = 1.56 * 10.09 = 15.74 A

Inputs from CEC Modules.csv for Hansol Technics Co Ltd HS330UB-JH2 {Wht}: Voc=41.0 V, beta_Voc=-0.28%/C, Isc=10.09 A, STC=330.0 W, Area=1.611 m2.

Result: 13 panels max on 600 V (585.3 V); 25 panels for 8 kW (434 sq ft).

What Are the Published CEC Specifications for Hansol Technics Co Ltd HS330UB-JH2 {Wht}?

Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for Hansol Technics Co Ltd HS330UB-JH2 {Wht}.

Official California Energy Commission (NREL SAM) test parameters for Hansol Technics Co Ltd HS330UB-JH2 {Wht}.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 330.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 309.3 W (93.7% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 41.0 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 10.09 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 34.9 V / 9.46 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.28 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 20.48% (1.611 m2) Array roof footprint density
Cell Count & Technology 60 cells (Mono-c-Si) Monofacial backsheet

How Many Hansol Technics Co Ltd HS330UB-JH2 {Wht} Panels Build a 6 kW, 8 kW, or 10 kW Array?

Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using Hansol Technics Co Ltd HS330UB-JH2 {Wht} (330.0 W).

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 19 6.27 kW 329 sq ft $1,569 $2,654
8 kW Class 25 8.25 kW 434 sq ft $2,065 $3,492
10 kW Class 31 10.23 kW 538 sq ft $2,560 $4,330

Which Sibling Wattage & Trim Variants Belong to This Hansol Technics Co Ltd Series?

All closely matched Hansol Technics Co Ltd wattages and cosmetic trims sharing the Hansol Technics Co Ltd HS330UB-JH2 {Wht} architecture.

Sibling CEC listings grouped into the Hansol Technics Co Ltd HS330UB-JH2 {Wht} wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
Hansol Technics Co Ltd HS325UB-JH2 {Wht} 325.0 W 304.5 W 40.8 V 34.7 V 20.17%
Hansol Technics Co Ltd HS330UB-JH2 {Wht} 330.0 W 309.3 W 41.0 V 34.9 V 20.48%
Hansol Technics Co Ltd HS335UB-JH2 {Wht} 335.0 W 314.1 W 41.2 V 35.1 V 20.79%

How Many Hansol Technics Co Ltd HS330UB-JH2 {Wht} Modules Fit in a Cold-Weather String?

Maximum series module counts for Hansol Technics Co Ltd HS330UB-JH2 {Wht} from 25 C down to -20 C (-4 F) under NEC 690.7.

Computed from Voc=41.0V and beta_Voc=-0.28%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 46.17 V 12 panels 554.0 V 21 panels
-10 C (14 F) 45.02 V 13 panels 585.3 V 22 panels
0 C (32 F) 43.87 V 13 panels 570.3 V 22 panels
25 C (77 F STC) 41.0 V 14 panels 574.0 V 24 panels

Which Cross-Brand Solar Modules Compare Closest to Hansol Technics Co Ltd HS330UB-JH2 {Wht}?

Alternative CEC solar modules from competing brands near Hansol Technics Co Ltd HS330UB-JH2 {Wht} (330.0 W), including CSI Solar Co Ltd CS3K-330MS.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
CSI Solar Co Ltd CS3K-330MS
CSI Solar Co Ltd
330.0 W Tie (0 W) 40.5 V 20.62% 93.2%
CertainTeed CT330HC11-04
CertainTeed
330.0 W Tie (0 W) 40.27 V 19.64% 90.8%
Boviet Solar Technology Co Ltd BVM6610M-330L-H
Boviet Solar Technology Co Ltd
330.0 W Tie (0 W) 41.9 V 19.76% 93.6%
Boviet Solar Technology Co Ltd BVM6610M-330-H
Boviet Solar Technology Co Ltd
330.0 W Tie (0 W) 41.95 V 20.25% 93.2%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for Hansol Technics Co Ltd HS330UB-JH2 {Wht}?

Evaluate Hansol Technics Co Ltd HS330UB-JH2 {Wht} (330.0 W STC, 41.0 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), Hansol Technics Co Ltd HS330UB-JH2 {Wht} reaches 46.17 V per panel—exceeding 12 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 25 panels for an 8 kW build require 434 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 25 panels (434 sq ft).
  • 2026 tax credit baseline: cash residential installs of Hansol Technics Co Ltd HS330UB-JH2 {Wht} carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

Hansol Technics Co Ltd HS330UB-JH2 {Wht} 8 kW Residential Fit

Needs 25 modules (434 sq ft) with a 20 A string OCPD, offsetting ~$2,065/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 13 panels (-10 C) or 12 panels (-20 C), or compare CSI Solar Co Ltd CS3K-330MS.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 309.3 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Hansol Technics Co Ltd HS330UB-JH2 {Wht} by Hansol Technics Co Ltd grounded in CEC test data and NEC 690.7/690.8 limits.

What fuse or breaker size does NEC 690.8 require for Hansol Technics Co Ltd HS330UB-JH2 {Wht}?

Multiplying Hansol Technics Co Ltd HS330UB-JH2 {Wht}'s 10.09 A short-circuit current by 1.56 equals 15.74 A minimum ampacity, requiring at least a 20 A overcurrent fuse or breaker.

Can Hansol Technics Co Ltd HS330UB-JH2 {Wht} pair with microinverters instead of a 600 V string inverter?

Yes—if the microinverter DC input ceiling exceeds 45.02 V cold Voc at 14 F and handles 10.09 A Isc; string inverters cap Hansol Technics Co Ltd HS330UB-JH2 {Wht} at 13 panels on 600 V.

Is Hansol Technics Co Ltd HS330UB-JH2 {Wht} eligible for the 30% federal 25D solar credit in 2026?

No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of Hansol Technics Co Ltd HS330UB-JH2 {Wht} rely on utility bill offset (~$2,065/yr at 8 kW) rather than 25D.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.