Hansol Technics Co Ltd HS330UB-HH2 is a 330.0 W STC (307.8 W PTC) Mono-c-Si solar module ranking #14,165 of 21,677 CEC listings (below all-CEC median; higher than 32.9% of peers). It delivers 19.9% efficiency, 41.4 V Voc at 25 C, and 45.28 V cold Voc at -10 C (13 panels max per 600 V string).
- STC Wattage
- 330.0 W
- PTC Wattage
- 307.8 W
- Voc @ 25C
- 41.4 V
- Efficiency
- 19.9%
How Does Hansol Technics Co Ltd HS330UB-HH2 Compare Against Peer CEC Listings?
Solar engineering breakdown for Hansol Technics Co Ltd HS330UB-HH2: PTC thermal retention, roof footprint, and cold Voc string bounds.
Across 5,889 Mono-c-Si listings from Hansol Technics Co Ltd and peers, Hansol Technics Co Ltd HS330UB-HH2 stands 80.0 W below the 410.0 W Mono-c-Si median and strong 93.3% PTC-to-STC heat retention (#8,323 of 21,677). Sizing 6 kW (19 panels) to 10 kW (31 panels) yields $1,569-$2,560/yr in baseline US bill offset. Mid-range 41.4 V open-circuit voltage allows up to 13 panels per 600 V string at 14 F.
Where Does Hansol Technics Co Ltd HS330UB-HH2 Fall Across Listed CEC Models?
Distribution marker showing Hansol Technics Co Ltd HS330UB-HH2 (330.0 W) relative to the 385.0 W all-CEC solar panel median.
What Dataset Percentiles Define Hansol Technics Co Ltd HS330UB-HH2?
Dataset percentiles tracking Hansol Technics Co Ltd HS330UB-HH2 power output, thermal retention ratio, and aperture efficiency against 21,677 models.
What Do the Dataset Ranks Show for Hansol Technics Co Ltd HS330UB-HH2?
Benchmark highlights for Hansol Technics Co Ltd HS330UB-HH2 covering STC output, efficiency, 8 kW footprint, and OCPD breaker size.
330.0 W STC · Higher Than 32.9%
330.0 W STC (-55.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.
19.9% Aperture Efficiency
Power density 199.0 W/m2 (0.01 percentage points below 19.91% CEC median). PTC/STC ratio: 93.3% (rank #8,323).
13 Panels Max @ -10 C (600 V)
Cold Voc reaches 45.28 V at -10 C (588.6 V string) and 46.39 V at -20 C (12 max).
25 Panels = 8,250 W STC
Occupies 41.4 m2 (446 sq ft) producing 7,695 W PTC; NEC 690.8 OCPD floor is 15.52 A (20 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 41.4 * (1 + (-0.268/100) * (-10 - 25)) = 45.28 V | OCPD = 1.56 * 9.95 = 15.52 A
Inputs from CEC Modules.csv for Hansol Technics Co Ltd HS330UB-HH2: Voc=41.4 V, beta_Voc=-0.268%/C, Isc=9.95 A, STC=330.0 W, Area=1.658 m2.
Result: 13 panels max on 600 V (588.6 V); 25 panels for 8 kW (446 sq ft).
What Are the Published CEC Specifications for Hansol Technics Co Ltd HS330UB-HH2?
Official CEC datasheet figures for Hansol Technics Co Ltd HS330UB-HH2 (Mono-c-Si) used in utility interconnection and permit reviews.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 330.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 307.8 W (93.3% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 41.4 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 9.95 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 35.3 V / 9.35 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.268 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 19.9% (1.658 m2) | Array roof footprint density |
| Cell Count & Technology | 60 cells (Mono-c-Si) | Monofacial backsheet |
How Many Hansol Technics Co Ltd HS330UB-HH2 Panels Build a 6 kW, 8 kW, or 10 kW Array?
How many Hansol Technics Co Ltd HS330UB-HH2 modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 19 | 6.27 kW | 339 sq ft | $1,569 | $2,654 |
| 8 kW Class | 25 | 8.25 kW | 446 sq ft | $2,065 | $3,492 |
| 10 kW Class | 31 | 10.23 kW | 553 sq ft | $2,560 | $4,330 |
Which Sibling Wattage & Trim Variants Belong to This Hansol Technics Co Ltd Series?
Consolidated Hansol Technics Co Ltd wattage variants sharing the Hansol Technics Co Ltd HS330UB-HH2 mechanical and cell layout.
| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| Hansol Technics Co Ltd HS325UB-HH2 | 325.0 W | 303.1 W | 41.2 V | 35.1 V | 19.6% |
| Hansol Technics Co Ltd HS330UB-HH2 | 330.0 W | 307.8 W | 41.4 V | 35.3 V | 19.9% |
| Hansol Technics Co Ltd HS335UB-HH2 | 335.0 W | 312.6 W | 41.6 V | 35.5 V | 20.21% |
How Many Hansol Technics Co Ltd HS330UB-HH2 Modules Fit in a Cold-Weather String?
NEC 690.7(A) winter string table preventing overvoltage trips on Hansol Technics Co Ltd HS330UB-HH2 (45.28 V at 14 F).
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 46.39 V | 12 panels | 556.7 V | 21 panels |
| -10 C (14 F) | 45.28 V | 13 panels | 588.6 V | 22 panels |
| 0 C (32 F) | 44.17 V | 13 panels | 574.2 V | 22 panels |
| 25 C (77 F STC) | 41.4 V | 14 panels | 579.6 V | 24 panels |
Which Cross-Brand Solar Modules Compare Closest to Hansol Technics Co Ltd HS330UB-HH2?
Competing CEC solar panels closest to Hansol Technics Co Ltd HS330UB-HH2 in nameplate wattage and Voc, starting with Boviet Solar Technology Co Ltd BVM6610M-330L-H.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| Boviet Solar Technology Co Ltd BVM6610M-330L-H Boviet Solar Technology Co Ltd |
330.0 W | Tie (0 W) | 41.9 V | 19.76% | 93.6% |
| Boviet Solar Technology Co Ltd BVM6610M-330-H Boviet Solar Technology Co Ltd |
330.0 W | Tie (0 W) | 41.95 V | 20.25% | 93.2% |
| Boviet Solar Technology Co Ltd BVM6610M-W5-330-H Boviet Solar Technology Co Ltd |
330.0 W | Tie (0 W) | 41.95 V | 20.28% | 93.2% |
| CSI Solar Co Ltd CS3K-330MS CSI Solar Co Ltd |
330.0 W | Tie (0 W) | 40.5 V | 20.62% | 93.2% |
What Are the Design Limits and Best-Fit Uses for Hansol Technics Co Ltd HS330UB-HH2?
Evaluate Hansol Technics Co Ltd HS330UB-HH2 (330.0 W STC, 41.4 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), Hansol Technics Co Ltd HS330UB-HH2 reaches 46.39 V per panel—exceeding 12 panels in series voids 600 V inverter warranties.
- Footprint constraint: 25 panels for an 8 kW build require 446 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 25 panels (446 sq ft).
- 2026 tax credit baseline: cash residential installs of Hansol Technics Co Ltd HS330UB-HH2 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
Hansol Technics Co Ltd HS330UB-HH2 8 kW Residential Fit
Needs 25 modules (446 sq ft) with a 20 A string OCPD, offsetting ~$2,065/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 13 panels (-10 C) or 12 panels (-20 C), or compare Boviet Solar Technology Co Ltd BVM6610M-330L-H.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 307.8 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for Hansol Technics Co Ltd HS330UB-HH2 by Hansol Technics Co Ltd grounded in CEC test data and NEC 690.7/690.8 limits.
What fuse or breaker size does NEC 690.8 require for Hansol Technics Co Ltd HS330UB-HH2?
Multiplying Hansol Technics Co Ltd HS330UB-HH2's 9.95 A short-circuit current by 1.56 equals 15.52 A minimum ampacity, requiring at least a 20 A overcurrent fuse or breaker.
Can Hansol Technics Co Ltd HS330UB-HH2 pair with microinverters instead of a 600 V string inverter?
Yes—if the microinverter DC input ceiling exceeds 45.28 V cold Voc at 14 F and handles 9.95 A Isc; string inverters cap Hansol Technics Co Ltd HS330UB-HH2 at 13 panels on 600 V.
Is Hansol Technics Co Ltd HS330UB-HH2 eligible for the 30% federal 25D solar credit in 2026?
No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of Hansol Technics Co Ltd HS330UB-HH2 rely on utility bill offset (~$2,065/yr at 8 kW) rather than 25D.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)