Skip to main content
WireAndSun
Calculators
CEC PV Module

Hansol Technics Co Ltd HS320UB-HH2 — CEC Solar Module Specifications

Manufacturer: Hansol Technics Co Ltd Registry: CEC Verified Engineering Specification

Hansol Technics Co Ltd HS320UB-HH2 is a 320.0 W STC (298.3 W PTC) Mono-c-Si solar module ranking #14,944 of 21,677 CEC listings (below all-CEC median; higher than 29.0% of peers). It delivers 19.3% efficiency, 41.0 V Voc at 25 C, and 44.85 V cold Voc at -10 C (13 panels max per 600 V string).

STC Wattage
320.0 W
PTC Wattage
298.3 W
Voc @ 25C
41.0 V
Efficiency
19.3%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does Hansol Technics Co Ltd HS320UB-HH2 Compare Against Peer CEC Listings?

CEC rank, roof space requirements, and NEC 690.7/690.8 limits for Hansol Technics Co Ltd HS320UB-HH2 (Mono-c-Si) residential solar systems.

Hansol Technics Co Ltd HS320UB-HH2 delivers 193.0 W/m2 (0.61 percentage points below 19.91% CEC median) and strong 93.2% PTC-to-STC heat retention (#8,924 of 21,677), placing it as a compact residential or specialty off-grid module useful on tight dormer roofs or battery cabins, though 8 kW requires 25 panels (446 sq ft). At -4 F (-20 C), string voltage climbs to 45.94 V per unit, capping 600 V circuits at 13 panels. Compare specs directly with Boviet Solar Technology Co Ltd BVM6610M-320L-H (320.0 W).

Where Does Hansol Technics Co Ltd HS320UB-HH2 Fall Across Listed CEC Models?

Comparison of Hansol Technics Co Ltd HS320UB-HH2 (320.0 W STC) against all 21,677 California Energy Commission certified photovoltaic modules.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where Hansol Technics Co Ltd HS320UB-HH2 (320.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCHansol Technics Co: 320.0 W

What Dataset Percentiles Define Hansol Technics Co Ltd HS320UB-HH2?

Relative ranking of Hansol Technics Co Ltd HS320UB-HH2 across nameplate watts, 93.2% PTC thermal ratio, and module aperture efficiency.

Hansol Technics Co Ltd HS320UB-HH2 Engineering BenchmarksPercentile comparison of Hansol Technics Co Ltd HS320UB-HH2 wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage320.0 WPTC/STC Retention93.2%Module Efficiency19.3%

What Do the Dataset Ranks Show for Hansol Technics Co Ltd HS320UB-HH2?

Summary of Hansol Technics Co Ltd HS320UB-HH2 output rank, 8 kW array size (25 panels), efficiency rating, and 600 V string limit.

Rank #14,944 / 21,677

320.0 W STC · Higher Than 29.0%

320.0 W STC (-65.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #12,724

19.3% Aperture Efficiency

Power density 193.0 W/m2 (0.61 percentage points below 19.91% CEC median). PTC/STC ratio: 93.2% (rank #8,924).

NEC 690.7 Limit

13 Panels Max @ -10 C (600 V)

Cold Voc reaches 44.85 V at -10 C (583.1 V string) and 45.94 V at -20 C (13 max).

8 kW Reference Array

25 Panels = 8,000 W STC

Occupies 41.4 m2 (446 sq ft) producing 7,458 W PTC; NEC 690.8 OCPD floor is 15.24 A (20 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 41.0 * (1 + (-0.268/100) * (-10 - 25)) = 44.85 V | OCPD = 1.56 * 9.77 = 15.24 A

Inputs from CEC Modules.csv for Hansol Technics Co Ltd HS320UB-HH2: Voc=41.0 V, beta_Voc=-0.268%/C, Isc=9.77 A, STC=320.0 W, Area=1.658 m2.

Result: 13 panels max on 600 V (583.1 V); 25 panels for 8 kW (446 sq ft).

What Are the Published CEC Specifications for Hansol Technics Co Ltd HS320UB-HH2?

Complete CEC test sheet for Hansol Technics Co Ltd HS320UB-HH2 including Isc (9.77 A), Voc (41.0 V), and thermal temperature coefficients.

Official California Energy Commission (NREL SAM) test parameters for Hansol Technics Co Ltd HS320UB-HH2.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 320.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 298.3 W (93.2% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 41.0 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 9.77 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 34.9 V / 9.17 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.268 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 19.3% (1.658 m2) Array roof footprint density
Cell Count & Technology 60 cells (Mono-c-Si) Monofacial backsheet

How Many Hansol Technics Co Ltd HS320UB-HH2 Panels Build a 6 kW, 8 kW, or 10 kW Array?

Residential array count and annual electric bill savings at 18.54 c/kWh US avg vs. California tariffs using Hansol Technics Co Ltd HS320UB-HH2.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 19 6.08 kW 339 sq ft $1,522 $2,573
8 kW Class 25 8.0 kW 446 sq ft $2,002 $3,386
10 kW Class 32 10.24 kW 571 sq ft $2,563 $4,334

Which Sibling Wattage & Trim Variants Belong to This Hansol Technics Co Ltd Series?

Related Hansol Technics Co Ltd power steps and black/silver trims consolidated into this Hansol Technics Co Ltd HS320UB-HH2 series guide.

Sibling CEC listings grouped into the Hansol Technics Co Ltd HS320UB-HH2 wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
Hansol Technics Co Ltd HS315UB-HH2 315.0 W 293.5 W 40.8 V 34.7 V 19.0%
Hansol Technics Co Ltd HS320UB-HH2 320.0 W 298.3 W 41.0 V 34.9 V 19.3%

How Many Hansol Technics Co Ltd HS320UB-HH2 Modules Fit in a Cold-Weather String?

Verify freezing-morning voltage rise for Hansol Technics Co Ltd HS320UB-HH2 (41.0 V STC) before wiring 600 V or 1,000 V strings.

Computed from Voc=41.0V and beta_Voc=-0.268%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 45.94 V 13 panels 597.2 V 21 panels
-10 C (14 F) 44.85 V 13 panels 583.1 V 22 panels
0 C (32 F) 43.75 V 13 panels 568.8 V 22 panels
25 C (77 F STC) 41.0 V 14 panels 574.0 V 24 panels

Which Cross-Brand Solar Modules Compare Closest to Hansol Technics Co Ltd HS320UB-HH2?

Four comparable CEC modules such as Boviet Solar Technology Co Ltd BVM6610M-320L-H (320.0 W) for side-by-side solar quote checks.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
Boviet Solar Technology Co Ltd BVM6610M-320L-H
Boviet Solar Technology Co Ltd
320.0 W Tie (0 W) 40.95 V 19.16% 93.6%
GCL System Integration Technology Co Ltd GCL-M6/60320
GCL System Integration Technology Co Ltd
320.0 W Tie (0 W) 40.3 V 19.63% 91.3%
Dehui Solar Power (Vietnam) CoLtd DH-M860F 320W
Dehui Solar Power (Vietnam) CoLtd
320.0 W Tie (0 W) 40.2 V 19.88% 92.9%
CSI Solar Co Ltd CS3K-320MS
CSI Solar Co Ltd
320.0 W Tie (0 W) 40.1 V 20.0% 93.2%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for Hansol Technics Co Ltd HS320UB-HH2?

Evaluate Hansol Technics Co Ltd HS320UB-HH2 (320.0 W STC, 41.0 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), Hansol Technics Co Ltd HS320UB-HH2 reaches 45.94 V per panel—exceeding 13 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 25 panels for an 8 kW build require 446 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 25 panels (446 sq ft).
  • 2026 tax credit baseline: cash residential installs of Hansol Technics Co Ltd HS320UB-HH2 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

Hansol Technics Co Ltd HS320UB-HH2 8 kW Residential Fit

Needs 25 modules (446 sq ft) with a 20 A string OCPD, offsetting ~$2,002/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 13 panels (-10 C) or 13 panels (-20 C), or compare Boviet Solar Technology Co Ltd BVM6610M-320L-H.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 298.3 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Hansol Technics Co Ltd HS320UB-HH2 by Hansol Technics Co Ltd grounded in CEC test data and NEC 690.7/690.8 limits.

How many Hansol Technics Co Ltd HS320UB-HH2 panels fit on a 600 V winter solar string?

At -10 C (14 F), Hansol Technics Co Ltd HS320UB-HH2 cold Voc rises from 41.0 V to 44.85 V (beta_Voc -0.268%/C), capping a 600 V string at 13 panels (583.1 V).

How much roof area does an 8 kW array of Hansol Technics Co Ltd HS320UB-HH2 need?

An 8 kW DC system uses 25 Hansol Technics Co Ltd HS320UB-HH2 modules (8,000 W STC / 7,458 W PTC), covering roughly 446 sq ft and saving ~$2,002/yr at 18.54 c/kWh.

How does Hansol Technics Co Ltd HS320UB-HH2 compare against Boviet Solar Technology Co Ltd BVM6610M-320L-H?

Hansol Technics Co Ltd HS320UB-HH2 outputs 320.0 W STC (41.0 V Voc, rank #14,944 of 21,677), while Boviet Solar Technology Co Ltd BVM6610M-320L-H delivers 320.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.