Skip to main content
WireAndSun
Calculators
CEC PV Module

Hansol Technics Co Ltd HS315ND-AN4 — CEC Solar Module Specifications

Manufacturer: Hansol Technics Co Ltd Registry: CEC Verified Engineering Specification

Hansol Technics Co Ltd HS315ND-AN4 is a 315.0 W STC (288.5 W PTC) Multi-c-Si solar module ranking #15,387 of 21,677 CEC listings (below all-CEC median; higher than 27.3% of peers). It delivers 16.28% efficiency, 45.7 V Voc at 25 C, and 50.61 V cold Voc at -10 C (11 panels max per 600 V string).

STC Wattage
315.0 W
PTC Wattage
288.5 W
Voc @ 25C
45.7 V
Efficiency
16.28%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does Hansol Technics Co Ltd HS315ND-AN4 Compare Against Peer CEC Listings?

CEC rank, roof space requirements, and NEC 690.7/690.8 limits for Hansol Technics Co Ltd HS315ND-AN4 (Multi-c-Si) residential solar systems.

Hansol Technics Co Ltd HS315ND-AN4 delivers 162.8 W/m2 (3.63 percentage points below 19.91% CEC median) and strong 91.6% PTC-to-STC heat retention (#15,328 of 21,677), placing it as a compact residential or specialty off-grid module useful on tight dormer roofs or battery cabins, though 8 kW requires 26 panels (542 sq ft). At -4 F (-20 C), string voltage climbs to 52.01 V per unit, capping 600 V circuits at 11 panels. Compare specs directly with Centrosolar America EP72 315BW (315.0 W).

Where Does Hansol Technics Co Ltd HS315ND-AN4 Fall Across Listed CEC Models?

Comparison of Hansol Technics Co Ltd HS315ND-AN4 (315.0 W STC) against all 21,677 California Energy Commission certified photovoltaic modules.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where Hansol Technics Co Ltd HS315ND-AN4 (315.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCHansol Technics Co: 315.0 W

What Dataset Percentiles Define Hansol Technics Co Ltd HS315ND-AN4?

Relative ranking of Hansol Technics Co Ltd HS315ND-AN4 across nameplate watts, 91.6% PTC thermal ratio, and module aperture efficiency.

Hansol Technics Co Ltd HS315ND-AN4 Engineering BenchmarksPercentile comparison of Hansol Technics Co Ltd HS315ND-AN4 wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage315.0 WPTC/STC Retention91.6%Module Efficiency16.28%

What Do the Dataset Ranks Show for Hansol Technics Co Ltd HS315ND-AN4?

Summary of Hansol Technics Co Ltd HS315ND-AN4 output rank, 8 kW array size (26 panels), efficiency rating, and 600 V string limit.

Rank #15,387 / 21,677

315.0 W STC · Higher Than 27.3%

315.0 W STC (-70.0 W vs all-CEC median) vs 278.8 W Multi-c-Si median.

Eff #17,701

16.28% Aperture Efficiency

Power density 162.8 W/m2 (3.63 percentage points below 19.91% CEC median). PTC/STC ratio: 91.6% (rank #15,328).

NEC 690.7 Limit

11 Panels Max @ -10 C (600 V)

Cold Voc reaches 50.61 V at -10 C (556.7 V string) and 52.01 V at -20 C (11 max).

8 kW Reference Array

26 Panels = 8,190 W STC

Occupies 50.3 m2 (542 sq ft) producing 7,501 W PTC; NEC 690.8 OCPD floor is 14.23 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 45.7 * (1 + (-0.307/100) * (-10 - 25)) = 50.61 V | OCPD = 1.56 * 9.12 = 14.23 A

Inputs from CEC Modules.csv for Hansol Technics Co Ltd HS315ND-AN4: Voc=45.7 V, beta_Voc=-0.307%/C, Isc=9.12 A, STC=315.0 W, Area=1.935 m2.

Result: 11 panels max on 600 V (556.7 V); 26 panels for 8 kW (542 sq ft).

What Are the Published CEC Specifications for Hansol Technics Co Ltd HS315ND-AN4?

Complete CEC test sheet for Hansol Technics Co Ltd HS315ND-AN4 including Isc (9.12 A), Voc (45.7 V), and thermal temperature coefficients.

Official California Energy Commission (NREL SAM) test parameters for Hansol Technics Co Ltd HS315ND-AN4.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 315.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 288.5 W (91.6% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 45.7 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 9.12 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 36.7 V / 8.59 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.307 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 16.28% (1.935 m2) Array roof footprint density
Cell Count & Technology 72 cells (Multi-c-Si) Monofacial backsheet

How Many Hansol Technics Co Ltd HS315ND-AN4 Panels Build a 6 kW, 8 kW, or 10 kW Array?

Residential array count and annual electric bill savings at 18.54 c/kWh US avg vs. California tariffs using Hansol Technics Co Ltd HS315ND-AN4.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 20 6.3 kW 417 sq ft $1,577 $2,666
8 kW Class 26 8.19 kW 542 sq ft $2,050 $3,466
10 kW Class 32 10.08 kW 667 sq ft $2,523 $4,266

Which Sibling Wattage & Trim Variants Belong to This Hansol Technics Co Ltd Series?

Related Hansol Technics Co Ltd power steps and black/silver trims consolidated into this Hansol Technics Co Ltd HS315ND-AN4 series guide.

Sibling CEC listings grouped into the Hansol Technics Co Ltd HS315ND-AN4 wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
Hansol Technics Co Ltd HS305ND-AN4 305.0 W 279.1 W 44.9 V 35.9 V 15.77%
Hansol Technics Co Ltd HS310ND-AN4 310.0 W 283.8 W 45.3 V 36.3 V 16.02%
Hansol Technics Co Ltd HS315ND-AN4 315.0 W 288.5 W 45.7 V 36.7 V 16.28%
Hansol Technics Co Ltd HS320ND-AN4 320.0 W 293.2 W 46.1 V 37.1 V 16.54%

How Many Hansol Technics Co Ltd HS315ND-AN4 Modules Fit in a Cold-Weather String?

Verify freezing-morning voltage rise for Hansol Technics Co Ltd HS315ND-AN4 (45.7 V STC) before wiring 600 V or 1,000 V strings.

Computed from Voc=45.7V and beta_Voc=-0.307%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 52.01 V 11 panels 572.1 V 19 panels
-10 C (14 F) 50.61 V 11 panels 556.7 V 19 panels
0 C (32 F) 49.21 V 12 panels 590.5 V 20 panels
25 C (77 F STC) 45.7 V 13 panels 594.1 V 21 panels

Which Cross-Brand Solar Modules Compare Closest to Hansol Technics Co Ltd HS315ND-AN4?

Four comparable CEC modules such as Centrosolar America EP72 315BW (315.0 W) for side-by-side solar quote checks. Regional housing vintage, storm hazard frequency, and wholesale utility prices directly govern residential upgrade payback across jurisdictions.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
Centrosolar America EP72 315BW
Centrosolar America
315.0 W Tie (0 W) 45.75 V 16.38% 91.2%
Centrosolar America EP72 315SW
Centrosolar America
315.0 W Tie (0 W) 45.75 V 16.38% 91.2%
GCL System Integration Technology Co Ltd GCL-P6/72315
GCL System Integration Technology Co Ltd
315.0 W Tie (0 W) 45.6 V 16.23% 90.5%
Boviet Solar Technology Co Ltd BVM6612M-315
Boviet Solar Technology Co Ltd
315.0 W Tie (0 W) 46.1 V 16.23% 90.5%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for Hansol Technics Co Ltd HS315ND-AN4?

Evaluate Hansol Technics Co Ltd HS315ND-AN4 (315.0 W STC, 45.7 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), Hansol Technics Co Ltd HS315ND-AN4 reaches 52.01 V per panel—exceeding 11 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 26 panels for an 8 kW build require 542 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 26 panels (542 sq ft).
  • 2026 tax credit baseline: cash residential installs of Hansol Technics Co Ltd HS315ND-AN4 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

Hansol Technics Co Ltd HS315ND-AN4 8 kW Residential Fit

Needs 26 modules (542 sq ft) with a 15 A string OCPD, offsetting ~$2,050/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 11 panels (-10 C) or 11 panels (-20 C), or compare Centrosolar America EP72 315BW.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 288.5 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Hansol Technics Co Ltd HS315ND-AN4 by Hansol Technics Co Ltd grounded in CEC test data and NEC 690.7/690.8 limits.

How many Hansol Technics Co Ltd HS315ND-AN4 panels fit on a 600 V winter solar string?

At -10 C (14 F), Hansol Technics Co Ltd HS315ND-AN4 cold Voc rises from 45.7 V to 50.61 V (beta_Voc -0.307%/C), capping a 600 V string at 11 panels (556.7 V).

How much roof area does an 8 kW array of Hansol Technics Co Ltd HS315ND-AN4 need?

An 8 kW DC system uses 26 Hansol Technics Co Ltd HS315ND-AN4 modules (8,190 W STC / 7,501 W PTC), covering roughly 542 sq ft and saving ~$2,050/yr at 18.54 c/kWh.

How does Hansol Technics Co Ltd HS315ND-AN4 compare against Centrosolar America EP72 315BW?

Hansol Technics Co Ltd HS315ND-AN4 outputs 315.0 W STC (45.7 V Voc, rank #15,387 of 21,677), while Centrosolar America EP72 315BW delivers 315.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.