Hansol Technics Co Ltd HS285TB-AN3 is a 285.0 W STC (255.6 W PTC) Multi-c-Si solar module ranking #17,598 of 21,677 CEC listings (below all-CEC median; higher than 17.3% of peers). It delivers 17.07% efficiency, 39.1 V Voc at 25 C, and 43.75 V cold Voc at -10 C (13 panels max per 600 V string).
- STC Wattage
- 285.0 W
- PTC Wattage
- 255.6 W
- Voc @ 25C
- 39.1 V
- Efficiency
- 17.07%
How Does Hansol Technics Co Ltd HS285TB-AN3 Compare Against Peer CEC Listings?
Solar engineering breakdown for Hansol Technics Co Ltd HS285TB-AN3: PTC thermal retention, roof footprint, and cold Voc string bounds.
Across 1,407 Multi-c-Si listings from Hansol Technics Co Ltd and peers, Hansol Technics Co Ltd HS285TB-AN3 stands 6.2 W above the 278.8 W Multi-c-Si median and typical 89.7% PTC-to-STC thermal output (255.6 W real-world rating). Sizing 6 kW (22 panels) to 10 kW (36 panels) yields $1,569-$2,568/yr in baseline US bill offset. Lower 39.1 V string voltage fits 13 panels in series at 14 F and pairs easily with microinverters.
Where Does Hansol Technics Co Ltd HS285TB-AN3 Fall Across Listed CEC Models?
Distribution marker showing Hansol Technics Co Ltd HS285TB-AN3 (285.0 W) relative to the 385.0 W all-CEC solar panel median.
What Dataset Percentiles Define Hansol Technics Co Ltd HS285TB-AN3?
Dataset percentiles tracking Hansol Technics Co Ltd HS285TB-AN3 power output, thermal retention ratio, and aperture efficiency against 21,677 models.
What Do the Dataset Ranks Show for Hansol Technics Co Ltd HS285TB-AN3?
Benchmark highlights for Hansol Technics Co Ltd HS285TB-AN3 covering STC output, efficiency, 8 kW footprint, and OCPD breaker size.
285.0 W STC · Higher Than 17.3%
285.0 W STC (-100.0 W vs all-CEC median) vs 278.8 W Multi-c-Si median.
17.07% Aperture Efficiency
Power density 170.7 W/m2 (2.84 percentage points below 19.91% CEC median). PTC/STC ratio: 89.7% (rank #19,653).
13 Panels Max @ -10 C (600 V)
Cold Voc reaches 43.75 V at -10 C (568.8 V string) and 45.08 V at -20 C (13 max).
29 Panels = 8,265 W STC
Occupies 48.4 m2 (521 sq ft) producing 7,412 W PTC; NEC 690.8 OCPD floor is 14.82 A (15 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 39.1 * (1 + (-0.34/100) * (-10 - 25)) = 43.75 V | OCPD = 1.56 * 9.5 = 14.82 A
Inputs from CEC Modules.csv for Hansol Technics Co Ltd HS285TB-AN3: Voc=39.1 V, beta_Voc=-0.34%/C, Isc=9.5 A, STC=285.0 W, Area=1.67 m2.
Result: 13 panels max on 600 V (568.8 V); 29 panels for 8 kW (521 sq ft).
What Are the Published CEC Specifications for Hansol Technics Co Ltd HS285TB-AN3?
Official CEC datasheet figures for Hansol Technics Co Ltd HS285TB-AN3 (Multi-c-Si) used in utility interconnection and permit reviews.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 285.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 255.6 W (89.7% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 39.1 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 9.5 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 31.8 V / 8.97 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.34 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 17.07% (1.67 m2) | Array roof footprint density |
| Cell Count & Technology | 60 cells (Multi-c-Si) | Monofacial backsheet |
How Many Hansol Technics Co Ltd HS285TB-AN3 Panels Build a 6 kW, 8 kW, or 10 kW Array?
How many Hansol Technics Co Ltd HS285TB-AN3 modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 22 | 6.27 kW | 395 sq ft | $1,569 | $2,654 |
| 8 kW Class | 29 | 8.27 kW | 521 sq ft | $2,070 | $3,500 |
| 10 kW Class | 36 | 10.26 kW | 647 sq ft | $2,568 | $4,342 |
Which Sibling Wattage & Trim Variants Belong to This Hansol Technics Co Ltd Series?
Consolidated Hansol Technics Co Ltd wattage variants sharing the Hansol Technics Co Ltd HS285TB-AN3 mechanical and cell layout.
| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| Hansol Technics Co Ltd HS275TB-AN3 | 275.0 W | 246.3 W | 38.3 V | 31.0 V | 16.47% |
| Hansol Technics Co Ltd HS280TB-AN3 | 280.0 W | 250.9 W | 38.7 V | 31.4 V | 16.77% |
| Hansol Technics Co Ltd HS285TB-AN3 | 285.0 W | 255.6 W | 39.1 V | 31.8 V | 17.07% |
| Hansol Technics Co Ltd HS290TB-AN3 | 290.0 W | 260.2 W | 39.5 V | 32.2 V | 17.37% |
| Hansol Technics Co Ltd HS295TB-AN3 | 295.0 W | 264.8 W | 39.9 V | 32.6 V | 17.66% |
How Many Hansol Technics Co Ltd HS285TB-AN3 Modules Fit in a Cold-Weather String?
NEC 690.7(A) winter string table preventing overvoltage trips on Hansol Technics Co Ltd HS285TB-AN3 (43.75 V at 14 F).
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 45.08 V | 13 panels | 586.0 V | 22 panels |
| -10 C (14 F) | 43.75 V | 13 panels | 568.8 V | 22 panels |
| 0 C (32 F) | 42.42 V | 14 panels | 593.9 V | 23 panels |
| 25 C (77 F STC) | 39.1 V | 15 panels | 586.5 V | 25 panels |
Which Cross-Brand Solar Modules Compare Closest to Hansol Technics Co Ltd HS285TB-AN3?
Competing CEC solar panels closest to Hansol Technics Co Ltd HS285TB-AN3 in nameplate wattage and Voc, starting with Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M30-285W.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M30-285W Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd |
285.0 W | Tie (0 W) | 39.18 V | 17.69% | 91.4% |
| Centrosolar America EM60 285BW Centrosolar America |
285.0 W | Tie (0 W) | 39.18 V | 17.69% | 91.4% |
| Centrosolar America EM60 285SW Centrosolar America |
285.0 W | Tie (0 W) | 39.18 V | 17.69% | 91.4% |
| Boviet Solar Technology Co Ltd BVM6610P-285 Boviet Solar Technology Co Ltd |
285.0 W | Tie (0 W) | 39.0 V | 17.52% | 92.5% |
What Are the Design Limits and Best-Fit Uses for Hansol Technics Co Ltd HS285TB-AN3?
Evaluate Hansol Technics Co Ltd HS285TB-AN3 (285.0 W STC, 39.1 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), Hansol Technics Co Ltd HS285TB-AN3 reaches 45.08 V per panel—exceeding 13 panels in series voids 600 V inverter warranties.
- Footprint constraint: 29 panels for an 8 kW build require 521 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 29 panels (521 sq ft).
- 2026 tax credit baseline: cash residential installs of Hansol Technics Co Ltd HS285TB-AN3 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
Hansol Technics Co Ltd HS285TB-AN3 8 kW Residential Fit
Needs 29 modules (521 sq ft) with a 15 A string OCPD, offsetting ~$2,070/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 13 panels (-10 C) or 13 panels (-20 C), or compare Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M30-285W.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 255.6 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for Hansol Technics Co Ltd HS285TB-AN3 by Hansol Technics Co Ltd grounded in CEC test data and NEC 690.7/690.8 limits.
What fuse or breaker size does NEC 690.8 require for Hansol Technics Co Ltd HS285TB-AN3?
Multiplying Hansol Technics Co Ltd HS285TB-AN3's 9.5 A short-circuit current by 1.56 equals 14.82 A minimum ampacity, requiring at least a 15 A overcurrent fuse or breaker.
Can Hansol Technics Co Ltd HS285TB-AN3 pair with microinverters instead of a 600 V string inverter?
Yes—if the microinverter DC input ceiling exceeds 43.75 V cold Voc at 14 F and handles 9.5 A Isc; string inverters cap Hansol Technics Co Ltd HS285TB-AN3 at 13 panels on 600 V.
Is Hansol Technics Co Ltd HS285TB-AN3 eligible for the 30% federal 25D solar credit in 2026?
No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of Hansol Technics Co Ltd HS285TB-AN3 rely on utility bill offset (~$2,070/yr at 8 kW) rather than 25D.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)