Hansol Technics Co Ltd HS265PB-AN1 is a 265.0 W STC (244.1 W PTC) Multi-c-Si solar module ranking #18,880 of 21,677 CEC listings (below all-CEC median; higher than 11.7% of peers). It delivers 16.46% efficiency, 37.7 V Voc at 25 C, and 41.7 V cold Voc at -10 C (14 panels max per 600 V string).
- STC Wattage
- 265.0 W
- PTC Wattage
- 244.1 W
- Voc @ 25C
- 37.7 V
- Efficiency
- 16.46%
How Does Hansol Technics Co Ltd HS265PB-AN1 Compare Against Peer CEC Listings?
Solar engineering breakdown for Hansol Technics Co Ltd HS265PB-AN1: PTC thermal retention, roof footprint, and cold Voc string bounds.
Across 1,407 Multi-c-Si listings from Hansol Technics Co Ltd and peers, Hansol Technics Co Ltd HS265PB-AN1 stands 13.8 W below the 278.8 W Multi-c-Si median and strong 92.1% PTC-to-STC heat retention (#13,846 of 21,677). Sizing 6 kW (23 panels) to 10 kW (38 panels) yields $1,524-$2,520/yr in baseline US bill offset. Lower 37.7 V string voltage fits 14 panels in series at 14 F and pairs easily with microinverters.
Where Does Hansol Technics Co Ltd HS265PB-AN1 Fall Across Listed CEC Models?
Distribution marker showing Hansol Technics Co Ltd HS265PB-AN1 (265.0 W) relative to the 385.0 W all-CEC solar panel median.
What Dataset Percentiles Define Hansol Technics Co Ltd HS265PB-AN1?
Dataset percentiles tracking Hansol Technics Co Ltd HS265PB-AN1 power output, thermal retention ratio, and aperture efficiency against 21,677 models.
What Do the Dataset Ranks Show for Hansol Technics Co Ltd HS265PB-AN1?
Benchmark highlights for Hansol Technics Co Ltd HS265PB-AN1 covering STC output, efficiency, 8 kW footprint, and OCPD breaker size.
265.0 W STC · Higher Than 11.7%
265.0 W STC (-120.0 W vs all-CEC median) vs 278.8 W Multi-c-Si median.
16.46% Aperture Efficiency
Power density 164.6 W/m2 (3.45 percentage points below 19.91% CEC median). PTC/STC ratio: 92.1% (rank #13,846).
14 Panels Max @ -10 C (600 V)
Cold Voc reaches 41.7 V at -10 C (583.8 V string) and 42.84 V at -20 C (14 max).
31 Panels = 8,215 W STC
Occupies 49.9 m2 (537 sq ft) producing 7,567 W PTC; NEC 690.8 OCPD floor is 14.16 A (15 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 37.7 * (1 + (-0.303/100) * (-10 - 25)) = 41.7 V | OCPD = 1.56 * 9.08 = 14.16 A
Inputs from CEC Modules.csv for Hansol Technics Co Ltd HS265PB-AN1: Voc=37.7 V, beta_Voc=-0.303%/C, Isc=9.08 A, STC=265.0 W, Area=1.61 m2.
Result: 14 panels max on 600 V (583.8 V); 31 panels for 8 kW (537 sq ft).
What Are the Published CEC Specifications for Hansol Technics Co Ltd HS265PB-AN1?
Official CEC datasheet figures for Hansol Technics Co Ltd HS265PB-AN1 (Multi-c-Si) used in utility interconnection and permit reviews.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 265.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 244.1 W (92.1% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 37.7 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 9.08 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 30.9 V / 8.59 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.303 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 16.46% (1.61 m2) | Array roof footprint density |
| Cell Count & Technology | 60 cells (Multi-c-Si) | Monofacial backsheet |
How Many Hansol Technics Co Ltd HS265PB-AN1 Panels Build a 6 kW, 8 kW, or 10 kW Array?
How many Hansol Technics Co Ltd HS265PB-AN1 modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 23 | 6.09 kW | 399 sq ft | $1,524 | $2,577 |
| 8 kW Class | 31 | 8.21 kW | 537 sq ft | $2,055 | $3,475 |
| 10 kW Class | 38 | 10.07 kW | 659 sq ft | $2,520 | $4,262 |
Which Sibling Wattage & Trim Variants Belong to This Hansol Technics Co Ltd Series?
Consolidated Hansol Technics Co Ltd wattage variants sharing the Hansol Technics Co Ltd HS265PB-AN1 mechanical and cell layout.
| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| Hansol Technics Co Ltd HS260PB-AN1 | 260.0 W | 239.4 W | 37.3 V | 30.5 V | 16.15% |
| Hansol Technics Co Ltd HS265PB-AN1 | 265.0 W | 244.1 W | 37.7 V | 30.9 V | 16.46% |
| Hansol Technics Co Ltd HS270PB-AN1 | 270.0 W | 248.8 W | 38.1 V | 31.3 V | 16.77% |
How Many Hansol Technics Co Ltd HS265PB-AN1 Modules Fit in a Cold-Weather String?
NEC 690.7(A) winter string table preventing overvoltage trips on Hansol Technics Co Ltd HS265PB-AN1 (41.7 V at 14 F).
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 42.84 V | 14 panels | 599.8 V | 23 panels |
| -10 C (14 F) | 41.7 V | 14 panels | 583.8 V | 23 panels |
| 0 C (32 F) | 40.56 V | 14 panels | 567.8 V | 24 panels |
| 25 C (77 F STC) | 37.7 V | 15 panels | 565.5 V | 26 panels |
Which Cross-Brand Solar Modules Compare Closest to Hansol Technics Co Ltd HS265PB-AN1?
Competing CEC solar panels closest to Hansol Technics Co Ltd HS265PB-AN1 in nameplate wattage and Voc, starting with Centrosolar America TM6 265xx.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| Centrosolar America TM6 265xx Centrosolar America |
265.0 W | Tie (0 W) | 38.0 V | 16.22% | 90.9% |
| Centrosolar America TM6S 265xx Centrosolar America |
265.0 W | Tie (0 W) | 38.0 V | 16.22% | 90.9% |
| GCL System Integration Technology Co Ltd GCL-P6/60265 GCL System Integration Technology Co Ltd |
265.0 W | Tie (0 W) | 38.1 V | 16.29% | 90.5% |
| GCL System Integration Technology Co Ltd GCL-P6/60B265 GCL System Integration Technology Co Ltd |
265.0 W | Tie (0 W) | 38.1 V | 16.26% | 90.2% |
What Are the Design Limits and Best-Fit Uses for Hansol Technics Co Ltd HS265PB-AN1?
Evaluate Hansol Technics Co Ltd HS265PB-AN1 (265.0 W STC, 37.7 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), Hansol Technics Co Ltd HS265PB-AN1 reaches 42.84 V per panel—exceeding 14 panels in series voids 600 V inverter warranties.
- Footprint constraint: 31 panels for an 8 kW build require 537 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 31 panels (537 sq ft).
- 2026 tax credit baseline: cash residential installs of Hansol Technics Co Ltd HS265PB-AN1 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
Hansol Technics Co Ltd HS265PB-AN1 8 kW Residential Fit
Needs 31 modules (537 sq ft) with a 15 A string OCPD, offsetting ~$2,055/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 14 panels (-10 C) or 14 panels (-20 C), or compare Centrosolar America TM6 265xx.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 244.1 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for Hansol Technics Co Ltd HS265PB-AN1 by Hansol Technics Co Ltd grounded in CEC test data and NEC 690.7/690.8 limits.
What fuse or breaker size does NEC 690.8 require for Hansol Technics Co Ltd HS265PB-AN1?
Multiplying Hansol Technics Co Ltd HS265PB-AN1's 9.08 A short-circuit current by 1.56 equals 14.16 A minimum ampacity, requiring at least a 15 A overcurrent fuse or breaker.
Can Hansol Technics Co Ltd HS265PB-AN1 pair with microinverters instead of a 600 V string inverter?
Yes—if the microinverter DC input ceiling exceeds 41.7 V cold Voc at 14 F and handles 9.08 A Isc; string inverters cap Hansol Technics Co Ltd HS265PB-AN1 at 14 panels on 600 V.
Is Hansol Technics Co Ltd HS265PB-AN1 eligible for the 30% federal 25D solar credit in 2026?
No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of Hansol Technics Co Ltd HS265PB-AN1 rely on utility bill offset (~$2,055/yr at 8 kW) rather than 25D.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)