Hansol Technics Co Ltd HS265NB-AN4 is a 265.0 W STC (242.9 W PTC) Multi-c-Si solar module ranking #18,880 of 21,677 CEC listings (below all-CEC median; higher than 11.7% of peers). It delivers 16.39% efficiency, 38.0 V Voc at 25 C, and 42.04 V cold Voc at -10 C (14 panels max per 600 V string).
- STC Wattage
- 265.0 W
- PTC Wattage
- 242.9 W
- Voc @ 25C
- 38.0 V
- Efficiency
- 16.39%
How Does Hansol Technics Co Ltd HS265NB-AN4 Compare Against Peer CEC Listings?
Engineering position of Hansol Technics Co Ltd HS265NB-AN4 (265.0 W STC) vs. Centrosolar America TM6 265xx across 1,407 CEC Multi-c-Si solar modules.
Ranking #18,880 across 21,677 CEC solar panels (below all-CEC median; higher than 11.7% of peers), Hansol Technics Co Ltd HS265NB-AN4 operates as a compact residential or specialty off-grid module sitting 13.8 W below the 278.8 W Multi-c-Si median. Lower 38.0 V string voltage fits 14 panels in series at 14 F and pairs easily with microinverters. With strong 91.7% PTC-to-STC heat retention (#15,053 of 21,677), 31 panels occupy 540 sq ft and offset roughly $2,055/yr at average US rates (or $3,475/yr in California). Monofacial backsheet sealing targets flush dark shingle rooftop mounts.
Where Does Hansol Technics Co Ltd HS265NB-AN4 Fall Across Listed CEC Models?
Plots Hansol Technics Co Ltd HS265NB-AN4 at 265.0 W STC across all 21,677 California Energy Commission photovoltaic modules relative to the 385.0 W median.
What Dataset Percentiles Define Hansol Technics Co Ltd HS265NB-AN4?
Benchmarks Hansol Technics Co Ltd HS265NB-AN4 on STC wattage, thermal PTC/STC retention, and 16.39 aperture conversion efficiency against CEC peers.
What Do the Dataset Ranks Show for Hansol Technics Co Ltd HS265NB-AN4?
Key electrical performance ranks, roof area sizing, and NEC 690.7/690.8 design boundaries for Hansol Technics Co Ltd HS265NB-AN4 by Hansol Technics Co Ltd.
265.0 W STC · Higher Than 11.7%
265.0 W STC (-120.0 W vs all-CEC median) vs 278.8 W Multi-c-Si median.
16.39% Aperture Efficiency
Power density 163.9 W/m2 (3.52 percentage points below 19.91% CEC median). PTC/STC ratio: 91.7% (rank #15,053).
14 Panels Max @ -10 C (600 V)
Cold Voc reaches 42.04 V at -10 C (588.6 V string) and 43.2 V at -20 C (13 max).
31 Panels = 8,215 W STC
Occupies 50.1 m2 (540 sq ft) producing 7,530 W PTC; NEC 690.8 OCPD floor is 14.23 A (15 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 38.0 * (1 + (-0.304/100) * (-10 - 25)) = 42.04 V | OCPD = 1.56 * 9.12 = 14.23 A
Inputs from CEC Modules.csv for Hansol Technics Co Ltd HS265NB-AN4: Voc=38.0 V, beta_Voc=-0.304%/C, Isc=9.12 A, STC=265.0 W, Area=1.617 m2.
Result: 14 panels max on 600 V (588.6 V); 31 panels for 8 kW (540 sq ft).
What Are the Published CEC Specifications for Hansol Technics Co Ltd HS265NB-AN4?
Laboratory test ratings recorded for Hansol Technics Co Ltd HS265NB-AN4 (Multi-c-Si) in the official California Energy Commission NREL SAM equipment catalog.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 265.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 242.9 W (91.7% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 38.0 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 9.12 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 30.9 V / 8.59 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.304 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 16.39% (1.617 m2) | Array roof footprint density |
| Cell Count & Technology | 60 cells (Multi-c-Si) | Monofacial backsheet |
How Many Hansol Technics Co Ltd HS265NB-AN4 Panels Build a 6 kW, 8 kW, or 10 kW Array?
Panel counts, roof square footage (540 sq ft at 8 kW), and estimated Year-1 electric bill offset for Hansol Technics Co Ltd HS265NB-AN4.
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 23 | 6.09 kW | 400 sq ft | $1,524 | $2,577 |
| 8 kW Class | 31 | 8.21 kW | 540 sq ft | $2,055 | $3,475 |
| 10 kW Class | 38 | 10.07 kW | 661 sq ft | $2,520 | $4,262 |
Which Sibling Wattage & Trim Variants Belong to This Hansol Technics Co Ltd Series?
Sibling wattage bins and frame colors grouped with Hansol Technics Co Ltd HS265NB-AN4 under Hansol Technics Co Ltd to prevent duplicate spec pages.
| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| Hansol Technics Co Ltd HS255NB-AN4 | 255.0 W | 233.5 W | 37.2 V | 30.1 V | 15.77% |
| Hansol Technics Co Ltd HS260NB-AN4 | 260.0 W | 238.2 W | 37.6 V | 30.5 V | 16.08% |
| Hansol Technics Co Ltd HS265NB-AN4 | 265.0 W | 242.9 W | 38.0 V | 30.9 V | 16.39% |
| Hansol Technics Co Ltd HS270NB-AN4 | 270.0 W | 247.6 W | 38.4 V | 31.3 V | 16.7% |
How Many Hansol Technics Co Ltd HS265NB-AN4 Modules Fit in a Cold-Weather String?
Cold-weather Voc escalation for Hansol Technics Co Ltd HS265NB-AN4 (beta_Voc -0.304%/C) across 600 V residential and 1,000 V commercial inverters.
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 43.2 V | 13 panels | 561.6 V | 23 panels |
| -10 C (14 F) | 42.04 V | 14 panels | 588.6 V | 23 panels |
| 0 C (32 F) | 40.89 V | 14 panels | 572.5 V | 24 panels |
| 25 C (77 F STC) | 38.0 V | 15 panels | 570.0 V | 26 panels |
Which Cross-Brand Solar Modules Compare Closest to Hansol Technics Co Ltd HS265NB-AN4?
Closest cross-brand CEC competitors to Hansol Technics Co Ltd HS265NB-AN4 matched near 265.0 W STC and 38.0 V Voc, led by Centrosolar America TM6 265xx.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| Centrosolar America TM6 265xx Centrosolar America |
265.0 W | Tie (0 W) | 38.0 V | 16.22% | 90.9% |
| Centrosolar America TM6S 265xx Centrosolar America |
265.0 W | Tie (0 W) | 38.0 V | 16.22% | 90.9% |
| GCL System Integration Technology Co Ltd GCL-P6/60265 GCL System Integration Technology Co Ltd |
265.0 W | Tie (0 W) | 38.1 V | 16.29% | 90.5% |
| GCL System Integration Technology Co Ltd GCL-P6/60B265 GCL System Integration Technology Co Ltd |
265.0 W | Tie (0 W) | 38.1 V | 16.26% | 90.2% |
What Are the Design Limits and Best-Fit Uses for Hansol Technics Co Ltd HS265NB-AN4?
Evaluate Hansol Technics Co Ltd HS265NB-AN4 (265.0 W STC, 38.0 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), Hansol Technics Co Ltd HS265NB-AN4 reaches 43.2 V per panel—exceeding 13 panels in series voids 600 V inverter warranties.
- Footprint constraint: 31 panels for an 8 kW build require 540 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 31 panels (540 sq ft).
- 2026 tax credit baseline: cash residential installs of Hansol Technics Co Ltd HS265NB-AN4 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
Hansol Technics Co Ltd HS265NB-AN4 8 kW Residential Fit
Needs 31 modules (540 sq ft) with a 15 A string OCPD, offsetting ~$2,055/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 14 panels (-10 C) or 13 panels (-20 C), or compare Centrosolar America TM6 265xx.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 242.9 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for Hansol Technics Co Ltd HS265NB-AN4 by Hansol Technics Co Ltd grounded in CEC test data and NEC 690.7/690.8 limits.
How many Hansol Technics Co Ltd HS265NB-AN4 panels fit on a 600 V winter solar string?
At -10 C (14 F), Hansol Technics Co Ltd HS265NB-AN4 cold Voc rises from 38.0 V to 42.04 V (beta_Voc -0.304%/C), capping a 600 V string at 14 panels (588.6 V).
How much roof area does an 8 kW array of Hansol Technics Co Ltd HS265NB-AN4 need?
An 8 kW DC system uses 31 Hansol Technics Co Ltd HS265NB-AN4 modules (8,215 W STC / 7,530 W PTC), covering roughly 540 sq ft and saving ~$2,055/yr at 18.54 c/kWh.
How does Hansol Technics Co Ltd HS265NB-AN4 compare against Centrosolar America TM6 265xx?
Hansol Technics Co Ltd HS265NB-AN4 outputs 265.0 W STC (38.0 V Voc, rank #18,880 of 21,677), while Centrosolar America TM6 265xx delivers 265.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)