Skip to main content
WireAndSun
Calculators
CEC PV Module

Hansol Technics Co Ltd HS260ME-V01 — CEC Solar Module Specifications

Manufacturer: Hansol Technics Co Ltd Registry: CEC Verified Engineering Specification

Hansol Technics Co Ltd HS260ME-V01 is a 260.0 W STC (233.9 W PTC) Multi-c-Si solar module ranking #19,146 of 21,677 CEC listings (below all-CEC median; higher than 10.4% of peers). It delivers 15.57% efficiency, 38.1 V Voc at 25 C, and 42.23 V cold Voc at -10 C (14 panels max per 600 V string).

STC Wattage
260.0 W
PTC Wattage
233.9 W
Voc @ 25C
38.1 V
Efficiency
15.57%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does Hansol Technics Co Ltd HS260ME-V01 Compare Against Peer CEC Listings?

How Hansol Technics Co Ltd Hansol Technics Co Ltd HS260ME-V01 handles rooftop heat (233.9 W PTC), 8 kW sizing, and cold winter string voltage.

Hansol Technics Co Ltd builds the Hansol Technics Co Ltd HS260ME-V01 (Multi-c-Si) as a compact residential or specialty off-grid module delivering 155.7 W/m2 (4.34 percentage points below 19.91% CEC median). Compared against Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6P30-260W (260.0 W), this model holds typical 90.0% PTC-to-STC thermal output (233.9 W real-world rating). Lower 38.1 V string voltage fits 14 panels in series at 14 F and pairs easily with microinverters, while NEC 690.8 sets a 13.81 A overcurrent floor served by a 15 A breaker.

Where Does Hansol Technics Co Ltd HS260ME-V01 Fall Across Listed CEC Models?

Where Hansol Technics Co Ltd HS260ME-V01 (260.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where Hansol Technics Co Ltd HS260ME-V01 (260.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCHansol Technics Co: 260.0 W

What Dataset Percentiles Define Hansol Technics Co Ltd HS260ME-V01?

Percentile placement of Hansol Technics Co Ltd HS260ME-V01 across power density (155.7 W/m2), thermal retention, and nameplate STC wattage.

Hansol Technics Co Ltd HS260ME-V01 Engineering BenchmarksPercentile comparison of Hansol Technics Co Ltd HS260ME-V01 wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage260.0 WPTC/STC Retention90.0%Module Efficiency15.57%

What Do the Dataset Ranks Show for Hansol Technics Co Ltd HS260ME-V01?

Four critical engineering numbers homeowners and solar installers check first when reviewing Hansol Technics Co Ltd HS260ME-V01 specifications.

Rank #19,146 / 21,677

260.0 W STC · Higher Than 10.4%

260.0 W STC (-125.0 W vs all-CEC median) vs 278.8 W Multi-c-Si median.

Eff #18,838

15.57% Aperture Efficiency

Power density 155.7 W/m2 (4.34 percentage points below 19.91% CEC median). PTC/STC ratio: 90.0% (rank #18,995).

NEC 690.7 Limit

14 Panels Max @ -10 C (600 V)

Cold Voc reaches 42.23 V at -10 C (591.2 V string) and 43.41 V at -20 C (13 max).

8 kW Reference Array

31 Panels = 8,060 W STC

Occupies 51.8 m2 (557 sq ft) producing 7,251 W PTC; NEC 690.8 OCPD floor is 13.81 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 38.1 * (1 + (-0.31/100) * (-10 - 25)) = 42.23 V | OCPD = 1.56 * 8.85 = 13.81 A

Inputs from CEC Modules.csv for Hansol Technics Co Ltd HS260ME-V01: Voc=38.1 V, beta_Voc=-0.31%/C, Isc=8.85 A, STC=260.0 W, Area=1.67 m2.

Result: 14 panels max on 600 V (591.2 V); 31 panels for 8 kW (557 sq ft).

What Are the Published CEC Specifications for Hansol Technics Co Ltd HS260ME-V01?

Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for Hansol Technics Co Ltd HS260ME-V01.

Official California Energy Commission (NREL SAM) test parameters for Hansol Technics Co Ltd HS260ME-V01.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 260.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 233.9 W (90.0% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 38.1 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 8.85 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 30.7 V / 8.48 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.31 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 15.57% (1.67 m2) Array roof footprint density
Cell Count & Technology 60 cells (Multi-c-Si) Monofacial backsheet

How Many Hansol Technics Co Ltd HS260ME-V01 Panels Build a 6 kW, 8 kW, or 10 kW Array?

Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using Hansol Technics Co Ltd HS260ME-V01 (260.0 W).

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 24 6.24 kW 431 sq ft $1,562 $2,641
8 kW Class 31 8.06 kW 557 sq ft $2,017 $3,411
10 kW Class 39 10.14 kW 701 sq ft $2,538 $4,292

Which Sibling Wattage & Trim Variants Belong to This Hansol Technics Co Ltd Series?

All closely matched Hansol Technics Co Ltd wattages and cosmetic trims sharing the Hansol Technics Co Ltd HS260ME-V01 architecture.

Sibling CEC listings grouped into the Hansol Technics Co Ltd HS260ME-V01 wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
Hansol Technics Co Ltd HS250ME-V01 250.0 W 223.6 W 37.9 V 30.5 V 15.62%
Hansol Technics Co Ltd HS255ME-V01 255.0 W 228.2 W 38.0 V 30.6 V 15.93%
Hansol Technics Co Ltd HS260ME-V01 260.0 W 233.9 W 38.1 V 30.7 V 15.57%
Hansol Technics Co Ltd HS265ME-V01 265.0 W 238.5 W 38.2 V 30.8 V 15.87%
Hansol Technics Co Ltd HS270ME-V01 270.0 W 243.2 W 38.3 V 30.9 V 16.17%

How Many Hansol Technics Co Ltd HS260ME-V01 Modules Fit in a Cold-Weather String?

Maximum series module counts for Hansol Technics Co Ltd HS260ME-V01 from 25 C down to -20 C (-4 F) under NEC 690.7.

Computed from Voc=38.1V and beta_Voc=-0.31%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 43.41 V 13 panels 564.3 V 23 panels
-10 C (14 F) 42.23 V 14 panels 591.2 V 23 panels
0 C (32 F) 41.05 V 14 panels 574.7 V 24 panels
25 C (77 F STC) 38.1 V 15 panels 571.5 V 26 panels

Which Cross-Brand Solar Modules Compare Closest to Hansol Technics Co Ltd HS260ME-V01?

Alternative CEC solar modules from competing brands near Hansol Technics Co Ltd HS260ME-V01 (260.0 W), including Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6P30-260W.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6P30-260W
Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd
260.0 W Tie (0 W) 38.0 V 16.01% 88.5%
Centrosolar America DM60 260
Centrosolar America
260.0 W Tie (0 W) 38.2 V 15.86% 90.8%
Chinaland Solar Energy HSE260-60M
Chinaland Solar Energy
260.0 W Tie (0 W) 38.0 V 16.01% 90.5%
Chinaland Solar Energy HSE260-60M-B
Chinaland Solar Energy
260.0 W Tie (0 W) 38.0 V 15.21% 90.4%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for Hansol Technics Co Ltd HS260ME-V01?

Evaluate Hansol Technics Co Ltd HS260ME-V01 (260.0 W STC, 38.1 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), Hansol Technics Co Ltd HS260ME-V01 reaches 43.41 V per panel—exceeding 13 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 31 panels for an 8 kW build require 557 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 31 panels (557 sq ft).
  • 2026 tax credit baseline: cash residential installs of Hansol Technics Co Ltd HS260ME-V01 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

Hansol Technics Co Ltd HS260ME-V01 8 kW Residential Fit

Needs 31 modules (557 sq ft) with a 15 A string OCPD, offsetting ~$2,017/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 14 panels (-10 C) or 13 panels (-20 C), or compare Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6P30-260W.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 233.9 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Hansol Technics Co Ltd HS260ME-V01 by Hansol Technics Co Ltd grounded in CEC test data and NEC 690.7/690.8 limits.

What fuse or breaker size does NEC 690.8 require for Hansol Technics Co Ltd HS260ME-V01?

Multiplying Hansol Technics Co Ltd HS260ME-V01's 8.85 A short-circuit current by 1.56 equals 13.81 A minimum ampacity, requiring at least a 15 A overcurrent fuse or breaker.

Can Hansol Technics Co Ltd HS260ME-V01 pair with microinverters instead of a 600 V string inverter?

Yes—if the microinverter DC input ceiling exceeds 42.23 V cold Voc at 14 F and handles 8.85 A Isc; string inverters cap Hansol Technics Co Ltd HS260ME-V01 at 14 panels on 600 V.

Is Hansol Technics Co Ltd HS260ME-V01 eligible for the 30% federal 25D solar credit in 2026?

No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of Hansol Technics Co Ltd HS260ME-V01 rely on utility bill offset (~$2,017/yr at 8 kW) rather than 25D.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.