Hansol Technics Co Ltd HS 395 XA-CLEA0 is a 395.0 W STC (377.0 W PTC) Mono-c-Si solar module ranking #9,869 of 21,677 CEC listings (top 47.6%; higher than 52.4% of peers). It delivers 29.92% efficiency, 37.0 V Voc at 25 C, and 40.08 V cold Voc at -10 C (14 panels max per 600 V string).
- STC Wattage
- 395.0 W
- PTC Wattage
- 377.0 W
- Voc @ 25C
- 37.0 V
- Efficiency
- 29.92%
How Does Hansol Technics Co Ltd HS 395 XA-CLEA0 Compare Against Peer CEC Listings?
How Hansol Technics Co Ltd Hansol Technics Co Ltd HS 395 XA-CLEA0 handles rooftop heat (377.0 W PTC), 8 kW sizing, and cold winter string voltage.
Hansol Technics Co Ltd builds the Hansol Technics Co Ltd HS 395 XA-CLEA0 (Mono-c-Si) as a modern high-density residential and light-commercial module delivering 299.2 W/m2 (10.01 percentage points above 19.91% CEC median). Compared against Changzhou EGing Photovoltaic Technology Co Ltd EG-395M54-HLV (395.0 W), this model holds strong 95.4% PTC-to-STC heat retention (#141 of 21,677). Lower 37.0 V string voltage fits 14 panels in series at 14 F and pairs easily with microinverters, while NEC 690.8 sets a 21.37 A overcurrent floor served by a 25 A breaker.
Where Does Hansol Technics Co Ltd HS 395 XA-CLEA0 Fall Across Listed CEC Models?
Where Hansol Technics Co Ltd HS 395 XA-CLEA0 (395.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.
What Dataset Percentiles Define Hansol Technics Co Ltd HS 395 XA-CLEA0?
Percentile placement of Hansol Technics Co Ltd HS 395 XA-CLEA0 across power density (299.2 W/m2), thermal retention, and nameplate STC wattage.
What Do the Dataset Ranks Show for Hansol Technics Co Ltd HS 395 XA-CLEA0?
Four critical engineering numbers homeowners and solar installers check first when reviewing Hansol Technics Co Ltd HS 395 XA-CLEA0 specifications.
Top 47.6% STC Output
395.0 W STC (+10.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.
29.92% Aperture Efficiency
Power density 299.2 W/m2 (10.01 percentage points above 19.91% CEC median). PTC/STC ratio: 95.4% (rank #141).
14 Panels Max @ -10 C (600 V)
Cold Voc reaches 40.08 V at -10 C (561.1 V string) and 40.96 V at -20 C (14 max).
21 Panels = 8,295 W STC
Occupies 27.7 m2 (298 sq ft) producing 7,917 W PTC; NEC 690.8 OCPD floor is 21.37 A (25 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 37.0 * (1 + (-0.238/100) * (-10 - 25)) = 40.08 V | OCPD = 1.56 * 13.7 = 21.37 A
Inputs from CEC Modules.csv for Hansol Technics Co Ltd HS 395 XA-CLEA0: Voc=37.0 V, beta_Voc=-0.238%/C, Isc=13.7 A, STC=395.0 W, Area=1.32 m2.
Result: 14 panels max on 600 V (561.1 V); 21 panels for 8 kW (298 sq ft).
What Are the Published CEC Specifications for Hansol Technics Co Ltd HS 395 XA-CLEA0?
Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for Hansol Technics Co Ltd HS 395 XA-CLEA0.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 395.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 377.0 W (95.4% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 37.0 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 13.7 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 30.8 V / 12.81 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.238 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 29.92% (1.32 m2) | Array roof footprint density |
| Cell Count & Technology | 54 cells (Mono-c-Si) | Monofacial backsheet |
How Many Hansol Technics Co Ltd HS 395 XA-CLEA0 Panels Build a 6 kW, 8 kW, or 10 kW Array?
Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using Hansol Technics Co Ltd HS 395 XA-CLEA0 (395.0 W).
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 16 | 6.32 kW | 227 sq ft | $1,582 | $2,675 |
| 8 kW Class | 21 | 8.29 kW | 298 sq ft | $2,075 | $3,509 |
| 10 kW Class | 26 | 10.27 kW | 369 sq ft | $2,570 | $4,347 |
How Many Hansol Technics Co Ltd HS 395 XA-CLEA0 Modules Fit in a Cold-Weather String?
Maximum series module counts for Hansol Technics Co Ltd HS 395 XA-CLEA0 from 25 C down to -20 C (-4 F) under NEC 690.7.
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 40.96 V | 14 panels | 573.4 V | 24 panels |
| -10 C (14 F) | 40.08 V | 14 panels | 561.1 V | 24 panels |
| 0 C (32 F) | 39.2 V | 15 panels | 588.0 V | 25 panels |
| 25 C (77 F STC) | 37.0 V | 16 panels | 592.0 V | 27 panels |
Which Cross-Brand Solar Modules Compare Closest to Hansol Technics Co Ltd HS 395 XA-CLEA0?
Alternative CEC solar modules from competing brands near Hansol Technics Co Ltd HS 395 XA-CLEA0 (395.0 W), including Changzhou EGing Photovoltaic Technology Co Ltd EG-395M54-HLV.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| Changzhou EGing Photovoltaic Technology Co Ltd EG-395M54-HLV Changzhou EGing Photovoltaic Technology Co Ltd |
395.0 W | Tie (0 W) | 37.0 V | 20.26% | 93.7% |
| Aptos Solar Technology LLC DNA-108-MF10-395W Aptos Solar Technology LLC |
395.0 W | Tie (0 W) | 36.98 V | 20.26% | 93.7% |
| CertainTeed CTM10395HC11-06 CertainTeed |
395.0 W | Tie (0 W) | 36.98 V | 20.26% | 93.7% |
| Elin Energy (Sirius PV) ELNSM54M-HC-395 Elin Energy (Sirius PV) |
395.0 W | Tie (0 W) | 37.02 V | 20.36% | 94.2% |
What Are the Design Limits and Best-Fit Uses for Hansol Technics Co Ltd HS 395 XA-CLEA0?
Evaluate Hansol Technics Co Ltd HS 395 XA-CLEA0 (395.0 W STC, 37.0 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), Hansol Technics Co Ltd HS 395 XA-CLEA0 reaches 40.96 V per panel—exceeding 14 panels in series voids 600 V inverter warranties.
- Footprint constraint: 21 panels for an 8 kW build require 298 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 21 panels (298 sq ft) for an 8 kW array.
- 2026 tax credit baseline: cash residential installs of Hansol Technics Co Ltd HS 395 XA-CLEA0 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
Hansol Technics Co Ltd HS 395 XA-CLEA0 8 kW Residential Fit
Needs 21 modules (298 sq ft) with a 25 A string OCPD, offsetting ~$2,075/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 14 panels (-10 C) or 14 panels (-20 C), or compare Changzhou EGing Photovoltaic Technology Co Ltd EG-395M54-HLV.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 377.0 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for Hansol Technics Co Ltd HS 395 XA-CLEA0 by Hansol Technics Co Ltd grounded in CEC test data and NEC 690.7/690.8 limits.
What fuse or breaker size does NEC 690.8 require for Hansol Technics Co Ltd HS 395 XA-CLEA0?
Multiplying Hansol Technics Co Ltd HS 395 XA-CLEA0's 13.7 A short-circuit current by 1.56 equals 21.37 A minimum ampacity, requiring at least a 25 A overcurrent fuse or breaker.
Can Hansol Technics Co Ltd HS 395 XA-CLEA0 pair with microinverters instead of a 600 V string inverter?
Yes—if the microinverter DC input ceiling exceeds 40.08 V cold Voc at 14 F and handles 13.7 A Isc; string inverters cap Hansol Technics Co Ltd HS 395 XA-CLEA0 at 14 panels on 600 V.
Is Hansol Technics Co Ltd HS 395 XA-CLEA0 eligible for the 30% federal 25D solar credit in 2026?
No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of Hansol Technics Co Ltd HS 395 XA-CLEA0 rely on utility bill offset (~$2,075/yr at 8 kW) rather than 25D.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)