Skip to main content
WireAndSun
Calculators
CEC PV Module

Hansol Technics Co Ltd HA600-AD-NNEA0 — CEC Solar Module Specifications

Manufacturer: Hansol Technics Co Ltd Registry: CEC Verified Engineering Specification

Hansol Technics Co Ltd HA600-AD-NNEA0 is a 600.0 W STC (559.9 W PTC) Mono-c-Si solar module ranking #1,320 of 21,677 CEC listings (top 6.7%; higher than 93.3% of peers). It delivers 23.44% efficiency, 52.3 V Voc at 25 C, and 58.03 V cold Voc at -10 C (10 panels max per 600 V string).

STC Wattage
600.0 W
PTC Wattage
559.9 W
Voc @ 25C
52.3 V
Efficiency
23.44%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does Hansol Technics Co Ltd HA600-AD-NNEA0 Compare Against Peer CEC Listings?

Engineering position of Hansol Technics Co Ltd HA600-AD-NNEA0 (600.0 W STC) vs. HD HYUNDAI ENERGY SOLUTIONS CO LTD HiN-T600NI across 5,889 CEC Mono-c-Si solar modules.

Ranking #1,320 across 21,677 CEC solar panels (top 6.7%; higher than 93.3% of peers), Hansol Technics Co Ltd HA600-AD-NNEA0 operates as a large-format commercial and ground-mount module sitting 190.0 W above the 410.0 W Mono-c-Si median. Higher 52.3 V open-circuit voltage caps 600 V residential strings at 10 panels at 14 F (-10 C). With strong 93.3% PTC-to-STC heat retention (#8,323 of 21,677), 14 panels occupy 386 sq ft and offset roughly $2,102/yr at average US rates (or $3,555/yr in California). Monofacial backsheet sealing targets flush dark shingle rooftop mounts.

Where Does Hansol Technics Co Ltd HA600-AD-NNEA0 Fall Across Listed CEC Models?

Plots Hansol Technics Co Ltd HA600-AD-NNEA0 at 600.0 W STC across all 21,677 California Energy Commission photovoltaic modules relative to the 385.0 W median.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where Hansol Technics Co Ltd HA600-AD-NNEA0 (600.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCHansol Technics Co: 600.0 W

What Dataset Percentiles Define Hansol Technics Co Ltd HA600-AD-NNEA0?

Benchmarks Hansol Technics Co Ltd HA600-AD-NNEA0 on STC wattage, thermal PTC/STC retention, and 23.44 aperture conversion efficiency against CEC peers.

Hansol Technics Co Ltd HA600-AD-NNEA0 Engineering BenchmarksPercentile comparison of Hansol Technics Co Ltd HA600-AD-NNEA0 wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage600.0 WPTC/STC Retention93.3%Module Efficiency23.44%

What Do the Dataset Ranks Show for Hansol Technics Co Ltd HA600-AD-NNEA0?

Key electrical performance ranks, roof area sizing, and NEC 690.7/690.8 design boundaries for Hansol Technics Co Ltd HA600-AD-NNEA0 by Hansol Technics Co Ltd.

Rank #1,320 / 21,677

Top 6.7% STC Output

600.0 W STC (+215.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #589

23.44% Aperture Efficiency

Power density 234.4 W/m2 (3.53 percentage points above 19.91% CEC median). PTC/STC ratio: 93.3% (rank #8,323).

NEC 690.7 Limit

10 Panels Max @ -10 C (600 V)

Cold Voc reaches 58.03 V at -10 C (580.3 V string) and 59.67 V at -20 C (10 max).

8 kW Reference Array

14 Panels = 8,400 W STC

Occupies 35.8 m2 (386 sq ft) producing 7,839 W PTC; NEC 690.8 OCPD floor is 22.76 A (25 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 52.3 * (1 + (-0.313/100) * (-10 - 25)) = 58.03 V | OCPD = 1.56 * 14.59 = 22.76 A

Inputs from CEC Modules.csv for Hansol Technics Co Ltd HA600-AD-NNEA0: Voc=52.3 V, beta_Voc=-0.313%/C, Isc=14.59 A, STC=600.0 W, Area=2.56 m2.

Result: 10 panels max on 600 V (580.3 V); 14 panels for 8 kW (386 sq ft).

What Are the Published CEC Specifications for Hansol Technics Co Ltd HA600-AD-NNEA0?

Laboratory test ratings recorded for Hansol Technics Co Ltd HA600-AD-NNEA0 (Mono-c-Si) in the official California Energy Commission NREL SAM equipment catalog.

Official California Energy Commission (NREL SAM) test parameters for Hansol Technics Co Ltd HA600-AD-NNEA0.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 600.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 559.9 W (93.3% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 52.3 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 14.59 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 43.6 V / 13.77 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.313 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 23.44% (2.56 m2) Array roof footprint density
Cell Count & Technology 72 cells (Mono-c-Si) Monofacial backsheet

How Many Hansol Technics Co Ltd HA600-AD-NNEA0 Panels Build a 6 kW, 8 kW, or 10 kW Array?

Panel counts, roof square footage (386 sq ft at 8 kW), and estimated Year-1 electric bill offset for Hansol Technics Co Ltd HA600-AD-NNEA0.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 10 6.0 kW 276 sq ft $1,502 $2,539
8 kW Class 14 8.4 kW 386 sq ft $2,102 $3,555
10 kW Class 17 10.2 kW 468 sq ft $2,553 $4,317

How Many Hansol Technics Co Ltd HA600-AD-NNEA0 Modules Fit in a Cold-Weather String?

Cold-weather Voc escalation for Hansol Technics Co Ltd HA600-AD-NNEA0 (beta_Voc -0.313%/C) across 600 V residential and 1,000 V commercial inverters.

Computed from Voc=52.3V and beta_Voc=-0.313%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 59.67 V 10 panels 596.7 V 16 panels
-10 C (14 F) 58.03 V 10 panels 580.3 V 17 panels
0 C (32 F) 56.39 V 10 panels 563.9 V 17 panels
25 C (77 F STC) 52.3 V 11 panels 575.3 V 19 panels

Which Cross-Brand Solar Modules Compare Closest to Hansol Technics Co Ltd HA600-AD-NNEA0?

Closest cross-brand CEC competitors to Hansol Technics Co Ltd HA600-AD-NNEA0 matched near 600.0 W STC and 52.3 V Voc, led by HD HYUNDAI ENERGY SOLUTIONS CO LTD HiN-T600NI.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
HD HYUNDAI ENERGY SOLUTIONS CO LTD HiN-T600NI
HD HYUNDAI ENERGY SOLUTIONS CO LTD
600.0 W Tie (0 W) 52.3 V 23.44% 93.3%
Mission Solar Energy LLC MSN10-600HN4G
Mission Solar Energy LLC
600.0 W Tie (0 W) 52.3 V 23.44% 93.3%
New East Solar Energy (Cambodia) CoLtd NESE600-72THB-M10
New East Solar Energy (Cambodia) CoLtd
600.0 W Tie (0 W) 52.3 V 23.44% 93.3%
Chint New Energy Technology Co Ltd CHSM72N-HC-600
Chint New Energy Technology Co Ltd
600.0 W Tie (0 W) 51.75 V 23.26% 94.8%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for Hansol Technics Co Ltd HA600-AD-NNEA0?

Evaluate Hansol Technics Co Ltd HA600-AD-NNEA0 (600.0 W STC, 52.3 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), Hansol Technics Co Ltd HA600-AD-NNEA0 reaches 59.67 V per panel—exceeding 10 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 14 panels for an 8 kW build require 386 sq ft of unshaded roof plane — better matched to wide open ground racks or commercial flat roofs than tight residential roof hips.
  • 2026 tax credit baseline: cash residential installs of Hansol Technics Co Ltd HA600-AD-NNEA0 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

Hansol Technics Co Ltd HA600-AD-NNEA0 8 kW Residential Fit

Needs 14 modules (386 sq ft) with a 25 A string OCPD, offsetting ~$2,102/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 10 panels (-10 C) or 10 panels (-20 C), or compare HD HYUNDAI ENERGY SOLUTIONS CO LTD HiN-T600NI.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 559.9 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Hansol Technics Co Ltd HA600-AD-NNEA0 by Hansol Technics Co Ltd grounded in CEC test data and NEC 690.7/690.8 limits.

How many Hansol Technics Co Ltd HA600-AD-NNEA0 panels fit on a 600 V winter solar string?

At -10 C (14 F), Hansol Technics Co Ltd HA600-AD-NNEA0 cold Voc rises from 52.3 V to 58.03 V (beta_Voc -0.313%/C), capping a 600 V string at 10 panels (580.3 V).

How much roof area does an 8 kW array of Hansol Technics Co Ltd HA600-AD-NNEA0 need?

An 8 kW DC system uses 14 Hansol Technics Co Ltd HA600-AD-NNEA0 modules (8,400 W STC / 7,839 W PTC), covering roughly 386 sq ft and saving ~$2,102/yr at 18.54 c/kWh.

How does Hansol Technics Co Ltd HA600-AD-NNEA0 compare against HD HYUNDAI ENERGY SOLUTIONS CO LTD HiN-T600NI?

Hansol Technics Co Ltd HA600-AD-NNEA0 outputs 600.0 W STC (52.3 V Voc, rank #1,320 of 21,677), while HD HYUNDAI ENERGY SOLUTIONS CO LTD HiN-T600NI delivers 600.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.