Hansol Technics Co Ltd HA600-AD-NNEA0 is a 600.0 W STC (559.9 W PTC) Mono-c-Si solar module ranking #1,320 of 21,677 CEC listings (top 6.7%; higher than 93.3% of peers). It delivers 23.44% efficiency, 52.3 V Voc at 25 C, and 58.03 V cold Voc at -10 C (10 panels max per 600 V string).
- STC Wattage
- 600.0 W
- PTC Wattage
- 559.9 W
- Voc @ 25C
- 52.3 V
- Efficiency
- 23.44%
How Does Hansol Technics Co Ltd HA600-AD-NNEA0 Compare Against Peer CEC Listings?
Engineering position of Hansol Technics Co Ltd HA600-AD-NNEA0 (600.0 W STC) vs. HD HYUNDAI ENERGY SOLUTIONS CO LTD HiN-T600NI across 5,889 CEC Mono-c-Si solar modules.
Ranking #1,320 across 21,677 CEC solar panels (top 6.7%; higher than 93.3% of peers), Hansol Technics Co Ltd HA600-AD-NNEA0 operates as a large-format commercial and ground-mount module sitting 190.0 W above the 410.0 W Mono-c-Si median. Higher 52.3 V open-circuit voltage caps 600 V residential strings at 10 panels at 14 F (-10 C). With strong 93.3% PTC-to-STC heat retention (#8,323 of 21,677), 14 panels occupy 386 sq ft and offset roughly $2,102/yr at average US rates (or $3,555/yr in California). Monofacial backsheet sealing targets flush dark shingle rooftop mounts.
Where Does Hansol Technics Co Ltd HA600-AD-NNEA0 Fall Across Listed CEC Models?
Plots Hansol Technics Co Ltd HA600-AD-NNEA0 at 600.0 W STC across all 21,677 California Energy Commission photovoltaic modules relative to the 385.0 W median.
What Dataset Percentiles Define Hansol Technics Co Ltd HA600-AD-NNEA0?
Benchmarks Hansol Technics Co Ltd HA600-AD-NNEA0 on STC wattage, thermal PTC/STC retention, and 23.44 aperture conversion efficiency against CEC peers.
What Do the Dataset Ranks Show for Hansol Technics Co Ltd HA600-AD-NNEA0?
Key electrical performance ranks, roof area sizing, and NEC 690.7/690.8 design boundaries for Hansol Technics Co Ltd HA600-AD-NNEA0 by Hansol Technics Co Ltd.
Top 6.7% STC Output
600.0 W STC (+215.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.
23.44% Aperture Efficiency
Power density 234.4 W/m2 (3.53 percentage points above 19.91% CEC median). PTC/STC ratio: 93.3% (rank #8,323).
10 Panels Max @ -10 C (600 V)
Cold Voc reaches 58.03 V at -10 C (580.3 V string) and 59.67 V at -20 C (10 max).
14 Panels = 8,400 W STC
Occupies 35.8 m2 (386 sq ft) producing 7,839 W PTC; NEC 690.8 OCPD floor is 22.76 A (25 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 52.3 * (1 + (-0.313/100) * (-10 - 25)) = 58.03 V | OCPD = 1.56 * 14.59 = 22.76 A
Inputs from CEC Modules.csv for Hansol Technics Co Ltd HA600-AD-NNEA0: Voc=52.3 V, beta_Voc=-0.313%/C, Isc=14.59 A, STC=600.0 W, Area=2.56 m2.
Result: 10 panels max on 600 V (580.3 V); 14 panels for 8 kW (386 sq ft).
What Are the Published CEC Specifications for Hansol Technics Co Ltd HA600-AD-NNEA0?
Laboratory test ratings recorded for Hansol Technics Co Ltd HA600-AD-NNEA0 (Mono-c-Si) in the official California Energy Commission NREL SAM equipment catalog.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 600.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 559.9 W (93.3% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 52.3 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 14.59 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 43.6 V / 13.77 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.313 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 23.44% (2.56 m2) | Array roof footprint density |
| Cell Count & Technology | 72 cells (Mono-c-Si) | Monofacial backsheet |
How Many Hansol Technics Co Ltd HA600-AD-NNEA0 Panels Build a 6 kW, 8 kW, or 10 kW Array?
Panel counts, roof square footage (386 sq ft at 8 kW), and estimated Year-1 electric bill offset for Hansol Technics Co Ltd HA600-AD-NNEA0.
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 10 | 6.0 kW | 276 sq ft | $1,502 | $2,539 |
| 8 kW Class | 14 | 8.4 kW | 386 sq ft | $2,102 | $3,555 |
| 10 kW Class | 17 | 10.2 kW | 468 sq ft | $2,553 | $4,317 |
How Many Hansol Technics Co Ltd HA600-AD-NNEA0 Modules Fit in a Cold-Weather String?
Cold-weather Voc escalation for Hansol Technics Co Ltd HA600-AD-NNEA0 (beta_Voc -0.313%/C) across 600 V residential and 1,000 V commercial inverters.
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 59.67 V | 10 panels | 596.7 V | 16 panels |
| -10 C (14 F) | 58.03 V | 10 panels | 580.3 V | 17 panels |
| 0 C (32 F) | 56.39 V | 10 panels | 563.9 V | 17 panels |
| 25 C (77 F STC) | 52.3 V | 11 panels | 575.3 V | 19 panels |
Which Cross-Brand Solar Modules Compare Closest to Hansol Technics Co Ltd HA600-AD-NNEA0?
Closest cross-brand CEC competitors to Hansol Technics Co Ltd HA600-AD-NNEA0 matched near 600.0 W STC and 52.3 V Voc, led by HD HYUNDAI ENERGY SOLUTIONS CO LTD HiN-T600NI.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| HD HYUNDAI ENERGY SOLUTIONS CO LTD HiN-T600NI HD HYUNDAI ENERGY SOLUTIONS CO LTD |
600.0 W | Tie (0 W) | 52.3 V | 23.44% | 93.3% |
| Mission Solar Energy LLC MSN10-600HN4G Mission Solar Energy LLC |
600.0 W | Tie (0 W) | 52.3 V | 23.44% | 93.3% |
| New East Solar Energy (Cambodia) CoLtd NESE600-72THB-M10 New East Solar Energy (Cambodia) CoLtd |
600.0 W | Tie (0 W) | 52.3 V | 23.44% | 93.3% |
| Chint New Energy Technology Co Ltd CHSM72N-HC-600 Chint New Energy Technology Co Ltd |
600.0 W | Tie (0 W) | 51.75 V | 23.26% | 94.8% |
What Are the Design Limits and Best-Fit Uses for Hansol Technics Co Ltd HA600-AD-NNEA0?
Evaluate Hansol Technics Co Ltd HA600-AD-NNEA0 (600.0 W STC, 52.3 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), Hansol Technics Co Ltd HA600-AD-NNEA0 reaches 59.67 V per panel—exceeding 10 panels in series voids 600 V inverter warranties.
- Footprint constraint: 14 panels for an 8 kW build require 386 sq ft of unshaded roof plane — better matched to wide open ground racks or commercial flat roofs than tight residential roof hips.
- 2026 tax credit baseline: cash residential installs of Hansol Technics Co Ltd HA600-AD-NNEA0 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
Hansol Technics Co Ltd HA600-AD-NNEA0 8 kW Residential Fit
Needs 14 modules (386 sq ft) with a 25 A string OCPD, offsetting ~$2,102/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 10 panels (-10 C) or 10 panels (-20 C), or compare HD HYUNDAI ENERGY SOLUTIONS CO LTD HiN-T600NI.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 559.9 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for Hansol Technics Co Ltd HA600-AD-NNEA0 by Hansol Technics Co Ltd grounded in CEC test data and NEC 690.7/690.8 limits.
How many Hansol Technics Co Ltd HA600-AD-NNEA0 panels fit on a 600 V winter solar string?
At -10 C (14 F), Hansol Technics Co Ltd HA600-AD-NNEA0 cold Voc rises from 52.3 V to 58.03 V (beta_Voc -0.313%/C), capping a 600 V string at 10 panels (580.3 V).
How much roof area does an 8 kW array of Hansol Technics Co Ltd HA600-AD-NNEA0 need?
An 8 kW DC system uses 14 Hansol Technics Co Ltd HA600-AD-NNEA0 modules (8,400 W STC / 7,839 W PTC), covering roughly 386 sq ft and saving ~$2,102/yr at 18.54 c/kWh.
How does Hansol Technics Co Ltd HA600-AD-NNEA0 compare against HD HYUNDAI ENERGY SOLUTIONS CO LTD HiN-T600NI?
Hansol Technics Co Ltd HA600-AD-NNEA0 outputs 600.0 W STC (52.3 V Voc, rank #1,320 of 21,677), while HD HYUNDAI ENERGY SOLUTIONS CO LTD HiN-T600NI delivers 600.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)