Hansol Technics Co Ltd HA555XD-GGEA0 is a 555.0 W STC (523.6 W PTC) Mono-c-Si solar module ranking #2,550 of 21,677 CEC listings (top 12.6%; higher than 87.4% of peers). It delivers 21.68% efficiency, 50.1 V Voc at 25 C, and 55.29 V cold Voc at -10 C (10 panels max per 600 V string).
- STC Wattage
- 555.0 W
- PTC Wattage
- 523.6 W
- Voc @ 25C
- 50.1 V
- Efficiency
- 21.68%
How Does Hansol Technics Co Ltd HA555XD-GGEA0 Compare Against Peer CEC Listings?
How Hansol Technics Co Ltd Hansol Technics Co Ltd HA555XD-GGEA0 handles rooftop heat (523.6 W PTC), 8 kW sizing, and cold winter string voltage.
For NEC string engineering, Hansol Technics Co Ltd HA555XD-GGEA0 exhibits 14.07 A short-circuit current, requiring a 21.95 A (156%) conductor rating and 25 A OCPD under NEC 690.8. Ranked #2,550 of 21,677 (145.0 W above the 410.0 W Mono-c-Si median), this large-format commercial and ground-mount module covers 38.4 m2 for an 8 kW system (19 panels for 10 kW). Higher 50.1 V open-circuit voltage caps 600 V residential strings at 10 panels at 14 F (-10 C).
Where Does Hansol Technics Co Ltd HA555XD-GGEA0 Fall Across Listed CEC Models?
Where Hansol Technics Co Ltd HA555XD-GGEA0 (555.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.
What Dataset Percentiles Define Hansol Technics Co Ltd HA555XD-GGEA0?
Percentile placement of Hansol Technics Co Ltd HA555XD-GGEA0 across power density (216.8 W/m2), thermal retention, and nameplate STC wattage.
What Do the Dataset Ranks Show for Hansol Technics Co Ltd HA555XD-GGEA0?
Four critical engineering numbers homeowners and solar installers check first when reviewing Hansol Technics Co Ltd HA555XD-GGEA0 specifications.
Top 12.6% STC Output
555.0 W STC (+170.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.
21.68% Aperture Efficiency
Power density 216.8 W/m2 (1.77 percentage points above 19.91% CEC median). PTC/STC ratio: 94.3% (rank #3,231).
10 Panels Max @ -10 C (600 V)
Cold Voc reaches 55.29 V at -10 C (552.9 V string) and 56.77 V at -20 C (10 max).
15 Panels = 8,325 W STC
Occupies 38.4 m2 (413 sq ft) producing 7,854 W PTC; NEC 690.8 OCPD floor is 21.95 A (25 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 50.1 * (1 + (-0.296/100) * (-10 - 25)) = 55.29 V | OCPD = 1.56 * 14.07 = 21.95 A
Inputs from CEC Modules.csv for Hansol Technics Co Ltd HA555XD-GGEA0: Voc=50.1 V, beta_Voc=-0.296%/C, Isc=14.07 A, STC=555.0 W, Area=2.56 m2.
Result: 10 panels max on 600 V (552.9 V); 15 panels for 8 kW (413 sq ft).
What Are the Published CEC Specifications for Hansol Technics Co Ltd HA555XD-GGEA0?
Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for Hansol Technics Co Ltd HA555XD-GGEA0.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 555.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 523.6 W (94.3% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 50.1 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 14.07 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 42.1 V / 13.18 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.296 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 21.68% (2.56 m2) | Array roof footprint density |
| Cell Count & Technology | 72 cells (Mono-c-Si) | Monofacial backsheet |
How Many Hansol Technics Co Ltd HA555XD-GGEA0 Panels Build a 6 kW, 8 kW, or 10 kW Array?
Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using Hansol Technics Co Ltd HA555XD-GGEA0 (555.0 W).
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 11 | 6.11 kW | 303 sq ft | $1,529 | $2,586 |
| 8 kW Class | 15 | 8.32 kW | 413 sq ft | $2,082 | $3,521 |
| 10 kW Class | 19 | 10.54 kW | 524 sq ft | $2,638 | $4,461 |
Which Sibling Wattage & Trim Variants Belong to This Hansol Technics Co Ltd Series?
All closely matched Hansol Technics Co Ltd wattages and cosmetic trims sharing the Hansol Technics Co Ltd HA555XD-GGEA0 architecture.
| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| Hansol Technics Co Ltd HA550XD-GGEA0 | 550.0 W | 518.8 W | 49.9 V | 42.0 V | 21.48% |
| Hansol Technics Co Ltd HA555XD-GGEA0 | 555.0 W | 523.6 W | 50.1 V | 42.1 V | 21.68% |
| Hansol Technics Co Ltd HA560XD-GGEA0 | 560.0 W | 528.5 W | 50.2 V | 42.3 V | 21.88% |
How Many Hansol Technics Co Ltd HA555XD-GGEA0 Modules Fit in a Cold-Weather String?
Maximum series module counts for Hansol Technics Co Ltd HA555XD-GGEA0 from 25 C down to -20 C (-4 F) under NEC 690.7.
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 56.77 V | 10 panels | 567.7 V | 17 panels |
| -10 C (14 F) | 55.29 V | 10 panels | 552.9 V | 18 panels |
| 0 C (32 F) | 53.81 V | 11 panels | 591.9 V | 18 panels |
| 25 C (77 F STC) | 50.1 V | 11 panels | 551.1 V | 19 panels |
Which Cross-Brand Solar Modules Compare Closest to Hansol Technics Co Ltd HA555XD-GGEA0?
Alternative CEC solar modules from competing brands near Hansol Technics Co Ltd HA555XD-GGEA0 (555.0 W), including Bluesun Solar CoLtd BSM555M10-72HPH.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| Bluesun Solar CoLtd BSM555M10-72HPH Bluesun Solar CoLtd |
555.0 W | Tie (0 W) | 50.08 V | 21.42% | 93.3% |
| G-Star Pte Ltd GSD7G72M-555BT G-Star Pte Ltd |
555.0 W | Tie (0 W) | 50.08 V | 21.68% | 94.3% |
| G-Star Pte Ltd GSD7G72M-555WT G-Star Pte Ltd |
555.0 W | Tie (0 W) | 50.08 V | 21.68% | 94.3% |
| AXITEC AC-555MH/144V AXITEC |
555.0 W | Tie (0 W) | 50.05 V | 21.68% | 93.6% |
What Are the Design Limits and Best-Fit Uses for Hansol Technics Co Ltd HA555XD-GGEA0?
Evaluate Hansol Technics Co Ltd HA555XD-GGEA0 (555.0 W STC, 50.1 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), Hansol Technics Co Ltd HA555XD-GGEA0 reaches 56.77 V per panel—exceeding 10 panels in series voids 600 V inverter warranties.
- Footprint constraint: 15 panels for an 8 kW build require 413 sq ft of unshaded roof plane — better matched to wide open ground racks or commercial flat roofs than tight residential roof hips.
- 2026 tax credit baseline: cash residential installs of Hansol Technics Co Ltd HA555XD-GGEA0 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
Hansol Technics Co Ltd HA555XD-GGEA0 8 kW Residential Fit
Needs 15 modules (413 sq ft) with a 25 A string OCPD, offsetting ~$2,082/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 10 panels (-10 C) or 10 panels (-20 C), or compare Bluesun Solar CoLtd BSM555M10-72HPH.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 523.6 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for Hansol Technics Co Ltd HA555XD-GGEA0 by Hansol Technics Co Ltd grounded in CEC test data and NEC 690.7/690.8 limits.
Why is Hansol Technics Co Ltd HA555XD-GGEA0 PTC wattage (523.6 W) lower than STC (555.0 W)?
Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 523.6 W PTC (94.3% retention) across Hansol Technics Co Ltd HA555XD-GGEA0's 2.56 m2 aperture.
Who should skip Hansol Technics Co Ltd HA555XD-GGEA0 on a complex residential roof?
Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 15 Hansol Technics Co Ltd HA555XD-GGEA0 panels (413 sq ft) leave unusable roof gaps vs. Bluesun Solar CoLtd BSM555M10-72HPH.
What is the 1,000 V commercial string limit for Hansol Technics Co Ltd HA555XD-GGEA0?
On 1,000 V commercial inverters at -10 C (55.29 V cold Voc), Hansol Technics Co Ltd HA555XD-GGEA0 fits up to 18 panels per series string.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)