Gintung Energy GTEC-265G6S6B is a 265.0 W STC (231.9 W PTC) Mono-c-Si solar module ranking #18,880 of 21,677 CEC listings (below all-CEC median; higher than 11.7% of peers). It delivers 14.94% efficiency, 40.88 V Voc at 25 C, and 45.79 V cold Voc at -10 C (13 panels max per 600 V string).
- STC Wattage
- 265.0 W
- PTC Wattage
- 231.9 W
- Voc @ 25C
- 40.88 V
- Efficiency
- 14.94%
How Does Gintung Energy GTEC-265G6S6B Compare Against Peer CEC Listings?
How Gintung Energy Gintung Energy GTEC-265G6S6B handles rooftop heat (231.9 W PTC), 8 kW sizing, and cold winter string voltage.
For NEC string engineering, Gintung Energy GTEC-265G6S6B exhibits 8.69 A short-circuit current, requiring a 13.56 A (156%) conductor rating and 15 A OCPD under NEC 690.8. Ranked #18,880 of 21,677 (145.0 W below the 410.0 W Mono-c-Si median), this compact residential or specialty off-grid module covers 55.0 m2 for an 8 kW system (38 panels for 10 kW). Mid-range 40.88 V open-circuit voltage allows up to 13 panels per 600 V string at 14 F.
Where Does Gintung Energy GTEC-265G6S6B Fall Across Listed CEC Models?
Where Gintung Energy GTEC-265G6S6B (265.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.
What Dataset Percentiles Define Gintung Energy GTEC-265G6S6B?
Percentile placement of Gintung Energy GTEC-265G6S6B across power density (149.5 W/m2), thermal retention, and nameplate STC wattage.
What Do the Dataset Ranks Show for Gintung Energy GTEC-265G6S6B?
Four critical engineering numbers homeowners and solar installers check first when reviewing Gintung Energy GTEC-265G6S6B specifications. Use these verified dataset benchmarks alongside a licensed electrician load calculation to compare residential upgrade bids with confidence.
265.0 W STC · Higher Than 11.7%
265.0 W STC (-120.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.
14.94% Aperture Efficiency
Power density 149.5 W/m2 (4.97 percentage points below 19.91% CEC median). PTC/STC ratio: 87.5% (rank #21,548).
13 Panels Max @ -10 C (600 V)
Cold Voc reaches 45.79 V at -10 C (595.3 V string) and 47.19 V at -20 C (12 max).
31 Panels = 8,215 W STC
Occupies 55.0 m2 (592 sq ft) producing 7,189 W PTC; NEC 690.8 OCPD floor is 13.56 A (15 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 40.88 * (1 + (-0.343/100) * (-10 - 25)) = 45.79 V | OCPD = 1.56 * 8.69 = 13.56 A
Inputs from CEC Modules.csv for Gintung Energy GTEC-265G6S6B: Voc=40.88 V, beta_Voc=-0.343%/C, Isc=8.69 A, STC=265.0 W, Area=1.773 m2.
Result: 13 panels max on 600 V (595.3 V); 31 panels for 8 kW (592 sq ft).
What Are the Published CEC Specifications for Gintung Energy GTEC-265G6S6B?
Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for Gintung Energy GTEC-265G6S6B.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 265.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 231.9 W (87.5% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 40.88 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 8.69 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 32.52 V / 8.15 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.343 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 14.94% (1.773 m2) | Array roof footprint density |
| Cell Count & Technology | 66 cells (Mono-c-Si) | Monofacial backsheet |
How Many Gintung Energy GTEC-265G6S6B Panels Build a 6 kW, 8 kW, or 10 kW Array?
Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using Gintung Energy GTEC-265G6S6B (265.0 W).
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 23 | 6.09 kW | 439 sq ft | $1,524 | $2,577 |
| 8 kW Class | 31 | 8.21 kW | 592 sq ft | $2,055 | $3,475 |
| 10 kW Class | 38 | 10.07 kW | 725 sq ft | $2,520 | $4,262 |
Which Sibling Wattage & Trim Variants Belong to This Gintung Energy Series?
All closely matched Gintung Energy wattages and cosmetic trims sharing the Gintung Energy GTEC-265G6S6B architecture. Always verify current state NEC adoption cycles, local utility interconnection tariffs, and panel busbar ratings before pulling project permits.
| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| Gintung Energy GTEC-260G6S6B | 260.0 W | 227.4 W | 40.73 V | 32.26 V | 14.66% |
| Gintung Energy GTEC-265G6S6B | 265.0 W | 231.9 W | 40.88 V | 32.52 V | 14.94% |
| Gintung Energy GTEC-270G6S6B | 270.0 W | 236.4 W | 40.97 V | 32.53 V | 15.23% |
How Many Gintung Energy GTEC-265G6S6B Modules Fit in a Cold-Weather String?
Maximum series module counts for Gintung Energy GTEC-265G6S6B from 25 C down to -20 C (-4 F) under NEC 690.7.
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 47.19 V | 12 panels | 566.3 V | 21 panels |
| -10 C (14 F) | 45.79 V | 13 panels | 595.3 V | 21 panels |
| 0 C (32 F) | 44.39 V | 13 panels | 577.1 V | 22 panels |
| 25 C (77 F STC) | 40.88 V | 14 panels | 572.3 V | 24 panels |
Which Cross-Brand Solar Modules Compare Closest to Gintung Energy GTEC-265G6S6B?
Alternative CEC solar modules from competing brands near Gintung Energy GTEC-265G6S6B (265.0 W), including Anhui Rinengzhongtian Semiconductor Development QJP265-72.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| Anhui Rinengzhongtian Semiconductor Development QJP265-72 Anhui Rinengzhongtian Semiconductor Development |
265.0 W | Tie (0 W) | 42.3 V | 13.66% | 89.1% |
| BYD Company Limited BYD 265P6C-36 BYD Company Limited |
265.0 W | Tie (0 W) | 43.11 V | 13.66% | 90.9% |
| Advance Power API-P265 Advance Power |
265.0 W | Tie (0 W) | 43.27 V | 13.58% | 89.1% |
| Auxin Solar AXN6P610T265 Auxin Solar |
265.0 W | Tie (0 W) | 43.27 V | 13.58% | 89.1% |
What Are the Design Limits and Best-Fit Uses for Gintung Energy GTEC-265G6S6B?
Evaluate Gintung Energy GTEC-265G6S6B (265.0 W STC, 40.88 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), Gintung Energy GTEC-265G6S6B reaches 47.19 V per panel—exceeding 12 panels in series voids 600 V inverter warranties.
- Footprint constraint: 31 panels for an 8 kW build require 592 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 31 panels (592 sq ft).
- 2026 tax credit baseline: cash residential installs of Gintung Energy GTEC-265G6S6B carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
Gintung Energy GTEC-265G6S6B 8 kW Residential Fit
Needs 31 modules (592 sq ft) with a 15 A string OCPD, offsetting ~$2,055/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 13 panels (-10 C) or 12 panels (-20 C), or compare Anhui Rinengzhongtian Semiconductor Development QJP265-72.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 231.9 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for Gintung Energy GTEC-265G6S6B by Gintung Energy grounded in CEC test data and NEC 690.7/690.8 limits.
Why is Gintung Energy GTEC-265G6S6B PTC wattage (231.9 W) lower than STC (265.0 W)?
Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 231.9 W PTC (87.5% retention) across Gintung Energy GTEC-265G6S6B's 1.773 m2 aperture.
Who should skip Gintung Energy GTEC-265G6S6B on a complex residential roof?
Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 31 Gintung Energy GTEC-265G6S6B panels (592 sq ft) leave unusable roof gaps vs. Anhui Rinengzhongtian Semiconductor Development QJP265-72.
What is the 1,000 V commercial string limit for Gintung Energy GTEC-265G6S6B?
On 1,000 V commercial inverters at -10 C (45.79 V cold Voc), Gintung Energy GTEC-265G6S6B fits up to 21 panels per series string. Review current municipal Authority Having Jurisdiction (AHJ) code amendments affecting Gintung Energy GTEC-265G6S6B.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)