Skip to main content
WireAndSun
Calculators
CEC PV Module

Gintung Energy GTEC-195G6S68 — CEC Solar Module Specifications

Manufacturer: Gintung Energy Registry: CEC Verified Engineering Specification

Gintung Energy GTEC-195G6S68 is a 195.0 W STC (175.0 W PTC) Mono-c-Si solar module ranking #21,088 of 21,677 CEC listings (below all-CEC median; higher than 2.5% of peers). It delivers 14.95% efficiency, 29.82 V Voc at 25 C, and 33.37 V cold Voc at -10 C (17 panels max per 600 V string).

STC Wattage
195.0 W
PTC Wattage
175.0 W
Voc @ 25C
29.82 V
Efficiency
14.95%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does Gintung Energy GTEC-195G6S68 Compare Against Peer CEC Listings?

How Gintung Energy Gintung Energy GTEC-195G6S68 handles rooftop heat (175.0 W PTC), 8 kW sizing, and cold winter string voltage.

For NEC string engineering, Gintung Energy GTEC-195G6S68 exhibits 8.63 A short-circuit current, requiring a 13.46 A (156%) conductor rating and 15 A OCPD under NEC 690.8. Ranked #21,088 of 21,677 (215.0 W below the 410.0 W Mono-c-Si median), this compact residential or specialty off-grid module covers 54.8 m2 for an 8 kW system (52 panels for 10 kW). Lower 29.82 V string voltage fits 17 panels in series at 14 F and pairs easily with microinverters.

Where Does Gintung Energy GTEC-195G6S68 Fall Across Listed CEC Models?

Where Gintung Energy GTEC-195G6S68 (195.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where Gintung Energy GTEC-195G6S68 (195.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCGintung Energy GTE: 195.0 W

What Dataset Percentiles Define Gintung Energy GTEC-195G6S68?

Percentile placement of Gintung Energy GTEC-195G6S68 across power density (149.5 W/m2), thermal retention, and nameplate STC wattage.

Gintung Energy GTEC-195G6S68 Engineering BenchmarksPercentile comparison of Gintung Energy GTEC-195G6S68 wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage195.0 WPTC/STC Retention89.7%Module Efficiency14.95%

What Do the Dataset Ranks Show for Gintung Energy GTEC-195G6S68?

Four critical engineering numbers homeowners and solar installers check first when reviewing Gintung Energy GTEC-195G6S68 specifications. Inspect manufacturer nameplate documentation, UL listing boundaries, and utility rate schedules closely before ordering electrical hardware.

Rank #21,088 / 21,677

195.0 W STC · Higher Than 2.5%

195.0 W STC (-190.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #19,805

14.95% Aperture Efficiency

Power density 149.5 W/m2 (4.96 percentage points below 19.91% CEC median). PTC/STC ratio: 89.7% (rank #19,653).

NEC 690.7 Limit

17 Panels Max @ -10 C (600 V)

Cold Voc reaches 33.37 V at -10 C (567.3 V string) and 34.38 V at -20 C (17 max).

8 kW Reference Array

42 Panels = 8,190 W STC

Occupies 54.8 m2 (590 sq ft) producing 7,350 W PTC; NEC 690.8 OCPD floor is 13.46 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 29.82 * (1 + (-0.34/100) * (-10 - 25)) = 33.37 V | OCPD = 1.56 * 8.63 = 13.46 A

Inputs from CEC Modules.csv for Gintung Energy GTEC-195G6S68: Voc=29.82 V, beta_Voc=-0.34%/C, Isc=8.63 A, STC=195.0 W, Area=1.304 m2.

Result: 17 panels max on 600 V (567.3 V); 42 panels for 8 kW (590 sq ft).

What Are the Published CEC Specifications for Gintung Energy GTEC-195G6S68?

Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for Gintung Energy GTEC-195G6S68.

Official California Energy Commission (NREL SAM) test parameters for Gintung Energy GTEC-195G6S68.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 195.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 175.0 W (89.7% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 29.82 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 8.63 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 23.67 V / 8.24 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.34 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 14.95% (1.304 m2) Array roof footprint density
Cell Count & Technology 48 cells (Mono-c-Si) Monofacial backsheet

How Many Gintung Energy GTEC-195G6S68 Panels Build a 6 kW, 8 kW, or 10 kW Array?

Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using Gintung Energy GTEC-195G6S68 (195.0 W).

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 31 6.04 kW 435 sq ft $1,512 $2,556
8 kW Class 42 8.19 kW 590 sq ft $2,050 $3,466
10 kW Class 52 10.14 kW 730 sq ft $2,538 $4,292

Which Sibling Wattage & Trim Variants Belong to This Gintung Energy Series?

All closely matched Gintung Energy wattages and cosmetic trims sharing the Gintung Energy GTEC-195G6S68 architecture. Data intervals combine current 2025 federal utility and BLS wage releases with verified state electrical board rosters.

Sibling CEC listings grouped into the Gintung Energy GTEC-195G6S68 wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
Gintung Energy GTEC-190G6S68 190.0 W 170.4 W 29.71 V 23.61 V 14.57%
Gintung Energy GTEC-195G6S68 195.0 W 175.0 W 29.82 V 23.67 V 14.95%

How Many Gintung Energy GTEC-195G6S68 Modules Fit in a Cold-Weather String?

Maximum series module counts for Gintung Energy GTEC-195G6S68 from 25 C down to -20 C (-4 F) under NEC 690.7.

Computed from Voc=29.82V and beta_Voc=-0.34%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 34.38 V 17 panels 584.5 V 29 panels
-10 C (14 F) 33.37 V 17 panels 567.3 V 29 panels
0 C (32 F) 32.35 V 18 panels 582.3 V 30 panels
25 C (77 F STC) 29.82 V 20 panels 596.4 V 33 panels

Which Cross-Brand Solar Modules Compare Closest to Gintung Energy GTEC-195G6S68?

Alternative CEC solar modules from competing brands near Gintung Energy GTEC-195G6S68 (195.0 W), including Shanghai ST Solar STP195-48.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
Shanghai ST Solar STP195-48
Shanghai ST Solar
195.0 W Tie (0 W) 30.0 V 14.58% 89.6%
Lightway Green New Energy LW190(23)P1310x990
Lightway Green New Energy
190.0 W -5.0 W 30.0 V 14.8% 89.6%
Mitsubishi Electric PV-UD190HA6
Mitsubishi Electric
190.0 W -5.0 W 30.5 V 13.74% 91.7%
Perfect Source Technology PST 188 3GP48
Perfect Source Technology
188.0 W -7.0 W 30.0 V 14.02% 89.3%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for Gintung Energy GTEC-195G6S68?

Evaluate Gintung Energy GTEC-195G6S68 (195.0 W STC, 29.82 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), Gintung Energy GTEC-195G6S68 reaches 34.38 V per panel—exceeding 17 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 42 panels for an 8 kW build require 590 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 42 panels (590 sq ft).
  • 2026 tax credit baseline: cash residential installs of Gintung Energy GTEC-195G6S68 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

Gintung Energy GTEC-195G6S68 8 kW Residential Fit

Needs 42 modules (590 sq ft) with a 15 A string OCPD, offsetting ~$2,050/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 17 panels (-10 C) or 17 panels (-20 C), or compare Shanghai ST Solar STP195-48.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 175.0 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Gintung Energy GTEC-195G6S68 by Gintung Energy grounded in CEC test data and NEC 690.7/690.8 limits.

Why is Gintung Energy GTEC-195G6S68 PTC wattage (175.0 W) lower than STC (195.0 W)?

Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 175.0 W PTC (89.7% retention) across Gintung Energy GTEC-195G6S68's 1.304 m2 aperture.

Who should skip Gintung Energy GTEC-195G6S68 on a complex residential roof?

Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 42 Gintung Energy GTEC-195G6S68 panels (590 sq ft) leave unusable roof gaps vs. Shanghai ST Solar STP195-48.

What is the 1,000 V commercial string limit for Gintung Energy GTEC-195G6S68?

On 1,000 V commercial inverters at -10 C (33.37 V cold Voc), Gintung Energy GTEC-195G6S68 fits up to 29 panels per series string. Review current municipal Authority Having Jurisdiction (AHJ) code amendments affecting Gintung Energy GTEC-195G6S68.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.