Gintung Energy GTEC-195G6S68 is a 195.0 W STC (175.0 W PTC) Mono-c-Si solar module ranking #21,088 of 21,677 CEC listings (below all-CEC median; higher than 2.5% of peers). It delivers 14.95% efficiency, 29.82 V Voc at 25 C, and 33.37 V cold Voc at -10 C (17 panels max per 600 V string).
- STC Wattage
- 195.0 W
- PTC Wattage
- 175.0 W
- Voc @ 25C
- 29.82 V
- Efficiency
- 14.95%
How Does Gintung Energy GTEC-195G6S68 Compare Against Peer CEC Listings?
How Gintung Energy Gintung Energy GTEC-195G6S68 handles rooftop heat (175.0 W PTC), 8 kW sizing, and cold winter string voltage.
For NEC string engineering, Gintung Energy GTEC-195G6S68 exhibits 8.63 A short-circuit current, requiring a 13.46 A (156%) conductor rating and 15 A OCPD under NEC 690.8. Ranked #21,088 of 21,677 (215.0 W below the 410.0 W Mono-c-Si median), this compact residential or specialty off-grid module covers 54.8 m2 for an 8 kW system (52 panels for 10 kW). Lower 29.82 V string voltage fits 17 panels in series at 14 F and pairs easily with microinverters.
Where Does Gintung Energy GTEC-195G6S68 Fall Across Listed CEC Models?
Where Gintung Energy GTEC-195G6S68 (195.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.
What Dataset Percentiles Define Gintung Energy GTEC-195G6S68?
Percentile placement of Gintung Energy GTEC-195G6S68 across power density (149.5 W/m2), thermal retention, and nameplate STC wattage.
What Do the Dataset Ranks Show for Gintung Energy GTEC-195G6S68?
Four critical engineering numbers homeowners and solar installers check first when reviewing Gintung Energy GTEC-195G6S68 specifications. Inspect manufacturer nameplate documentation, UL listing boundaries, and utility rate schedules closely before ordering electrical hardware.
195.0 W STC · Higher Than 2.5%
195.0 W STC (-190.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.
14.95% Aperture Efficiency
Power density 149.5 W/m2 (4.96 percentage points below 19.91% CEC median). PTC/STC ratio: 89.7% (rank #19,653).
17 Panels Max @ -10 C (600 V)
Cold Voc reaches 33.37 V at -10 C (567.3 V string) and 34.38 V at -20 C (17 max).
42 Panels = 8,190 W STC
Occupies 54.8 m2 (590 sq ft) producing 7,350 W PTC; NEC 690.8 OCPD floor is 13.46 A (15 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 29.82 * (1 + (-0.34/100) * (-10 - 25)) = 33.37 V | OCPD = 1.56 * 8.63 = 13.46 A
Inputs from CEC Modules.csv for Gintung Energy GTEC-195G6S68: Voc=29.82 V, beta_Voc=-0.34%/C, Isc=8.63 A, STC=195.0 W, Area=1.304 m2.
Result: 17 panels max on 600 V (567.3 V); 42 panels for 8 kW (590 sq ft).
What Are the Published CEC Specifications for Gintung Energy GTEC-195G6S68?
Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for Gintung Energy GTEC-195G6S68.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 195.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 175.0 W (89.7% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 29.82 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 8.63 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 23.67 V / 8.24 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.34 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 14.95% (1.304 m2) | Array roof footprint density |
| Cell Count & Technology | 48 cells (Mono-c-Si) | Monofacial backsheet |
How Many Gintung Energy GTEC-195G6S68 Panels Build a 6 kW, 8 kW, or 10 kW Array?
Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using Gintung Energy GTEC-195G6S68 (195.0 W).
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 31 | 6.04 kW | 435 sq ft | $1,512 | $2,556 |
| 8 kW Class | 42 | 8.19 kW | 590 sq ft | $2,050 | $3,466 |
| 10 kW Class | 52 | 10.14 kW | 730 sq ft | $2,538 | $4,292 |
Which Sibling Wattage & Trim Variants Belong to This Gintung Energy Series?
All closely matched Gintung Energy wattages and cosmetic trims sharing the Gintung Energy GTEC-195G6S68 architecture. Data intervals combine current 2025 federal utility and BLS wage releases with verified state electrical board rosters.
| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| Gintung Energy GTEC-190G6S68 | 190.0 W | 170.4 W | 29.71 V | 23.61 V | 14.57% |
| Gintung Energy GTEC-195G6S68 | 195.0 W | 175.0 W | 29.82 V | 23.67 V | 14.95% |
How Many Gintung Energy GTEC-195G6S68 Modules Fit in a Cold-Weather String?
Maximum series module counts for Gintung Energy GTEC-195G6S68 from 25 C down to -20 C (-4 F) under NEC 690.7.
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 34.38 V | 17 panels | 584.5 V | 29 panels |
| -10 C (14 F) | 33.37 V | 17 panels | 567.3 V | 29 panels |
| 0 C (32 F) | 32.35 V | 18 panels | 582.3 V | 30 panels |
| 25 C (77 F STC) | 29.82 V | 20 panels | 596.4 V | 33 panels |
Which Cross-Brand Solar Modules Compare Closest to Gintung Energy GTEC-195G6S68?
Alternative CEC solar modules from competing brands near Gintung Energy GTEC-195G6S68 (195.0 W), including Shanghai ST Solar STP195-48.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| Shanghai ST Solar STP195-48 Shanghai ST Solar |
195.0 W | Tie (0 W) | 30.0 V | 14.58% | 89.6% |
| Lightway Green New Energy LW190(23)P1310x990 Lightway Green New Energy |
190.0 W | -5.0 W | 30.0 V | 14.8% | 89.6% |
| Mitsubishi Electric PV-UD190HA6 Mitsubishi Electric |
190.0 W | -5.0 W | 30.5 V | 13.74% | 91.7% |
| Perfect Source Technology PST 188 3GP48 Perfect Source Technology |
188.0 W | -7.0 W | 30.0 V | 14.02% | 89.3% |
What Are the Design Limits and Best-Fit Uses for Gintung Energy GTEC-195G6S68?
Evaluate Gintung Energy GTEC-195G6S68 (195.0 W STC, 29.82 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), Gintung Energy GTEC-195G6S68 reaches 34.38 V per panel—exceeding 17 panels in series voids 600 V inverter warranties.
- Footprint constraint: 42 panels for an 8 kW build require 590 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 42 panels (590 sq ft).
- 2026 tax credit baseline: cash residential installs of Gintung Energy GTEC-195G6S68 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
Gintung Energy GTEC-195G6S68 8 kW Residential Fit
Needs 42 modules (590 sq ft) with a 15 A string OCPD, offsetting ~$2,050/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 17 panels (-10 C) or 17 panels (-20 C), or compare Shanghai ST Solar STP195-48.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 175.0 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for Gintung Energy GTEC-195G6S68 by Gintung Energy grounded in CEC test data and NEC 690.7/690.8 limits.
Why is Gintung Energy GTEC-195G6S68 PTC wattage (175.0 W) lower than STC (195.0 W)?
Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 175.0 W PTC (89.7% retention) across Gintung Energy GTEC-195G6S68's 1.304 m2 aperture.
Who should skip Gintung Energy GTEC-195G6S68 on a complex residential roof?
Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 42 Gintung Energy GTEC-195G6S68 panels (590 sq ft) leave unusable roof gaps vs. Shanghai ST Solar STP195-48.
What is the 1,000 V commercial string limit for Gintung Energy GTEC-195G6S68?
On 1,000 V commercial inverters at -10 C (33.37 V cold Voc), Gintung Energy GTEC-195G6S68 fits up to 29 panels per series string. Review current municipal Authority Having Jurisdiction (AHJ) code amendments affecting Gintung Energy GTEC-195G6S68.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)