GCL System Integration Technology Co Ltd GCL-M6/72GDF380 is a 380.0 W STC (356.1 W PTC) Mono-c-Si solar module ranking #11,043 of 21,677 CEC listings (below all-CEC median; higher than 47.6% of peers). It delivers 18.91% efficiency, 48.53 V Voc at 25 C, and 53.18 V cold Voc at -10 C (11 panels max per 600 V string).
- STC Wattage
- 380.0 W
- PTC Wattage
- 356.1 W
- Voc @ 25C
- 48.53 V
- Efficiency
- 18.91%
How Does GCL System Integration Technology Co Ltd GCL-M6/72GDF380 Compare Against Peer CEC Listings?
Solar engineering breakdown for GCL System Integration Technology Co Ltd GCL-M6/72GDF380: PTC thermal retention, roof footprint, and cold Voc string bounds.
Across 5,889 Mono-c-Si listings from GCL System Integration Technology Co Ltd and peers, GCL System Integration Technology Co Ltd GCL-M6/72GDF380 stands 30.0 W below the 410.0 W Mono-c-Si median and strong 93.7% PTC-to-STC heat retention (#6,162 of 21,677). Sizing 6 kW (16 panels) to 10 kW (27 panels) yields $1,522-$2,568/yr in baseline US bill offset. Higher 48.53 V open-circuit voltage caps 600 V residential strings at 11 panels at 14 F (-10 C).
Where Does GCL System Integration Technology Co Ltd GCL-M6/72GDF380 Fall Across Listed CEC Models?
Distribution marker showing GCL System Integration Technology Co Ltd GCL-M6/72GDF380 (380.0 W) relative to the 385.0 W all-CEC solar panel median.
What Dataset Percentiles Define GCL System Integration Technology Co Ltd GCL-M6/72GDF380?
Dataset percentiles tracking GCL System Integration Technology Co Ltd GCL-M6/72GDF380 power output, thermal retention ratio, and aperture efficiency against 21,677 models.
What Do the Dataset Ranks Show for GCL System Integration Technology Co Ltd GCL-M6/72GDF380?
Benchmark highlights for GCL System Integration Technology Co Ltd GCL-M6/72GDF380 covering STC output, efficiency, 8 kW footprint, and OCPD breaker size.
380.0 W STC · Higher Than 47.6%
380.0 W STC (-5.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.
18.91% Aperture Efficiency
Power density 189.1 W/m2 (1.00 percentage points below 19.91% CEC median). PTC/STC ratio: 93.7% (rank #6,162).
11 Panels Max @ -10 C (600 V)
Cold Voc reaches 53.18 V at -10 C (585.0 V string) and 54.51 V at -20 C (11 max).
22 Panels = 8,360 W STC
Occupies 44.2 m2 (476 sq ft) producing 7,834 W PTC; NEC 690.8 OCPD floor is 15.66 A (20 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 48.53 * (1 + (-0.274/100) * (-10 - 25)) = 53.18 V | OCPD = 1.56 * 10.04 = 15.66 A
Inputs from CEC Modules.csv for GCL System Integration Technology Co Ltd GCL-M6/72GDF380: Voc=48.53 V, beta_Voc=-0.274%/C, Isc=10.04 A, STC=380.0 W, Area=2.01 m2.
Result: 11 panels max on 600 V (585.0 V); 22 panels for 8 kW (476 sq ft).
What Are the Published CEC Specifications for GCL System Integration Technology Co Ltd GCL-M6/72GDF380?
Official CEC datasheet figures for GCL System Integration Technology Co Ltd GCL-M6/72GDF380 (Mono-c-Si) used in utility interconnection and permit reviews.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 380.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 356.1 W (93.7% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 48.53 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 10.04 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 39.72 V / 9.57 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.274 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 18.91% (2.01 m2) | Array roof footprint density |
| Cell Count & Technology | 72 cells (Mono-c-Si) | Monofacial backsheet |
How Many GCL System Integration Technology Co Ltd GCL-M6/72GDF380 Panels Build a 6 kW, 8 kW, or 10 kW Array?
How many GCL System Integration Technology Co Ltd GCL-M6/72GDF380 modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 16 | 6.08 kW | 346 sq ft | $1,522 | $2,573 |
| 8 kW Class | 22 | 8.36 kW | 476 sq ft | $2,092 | $3,538 |
| 10 kW Class | 27 | 10.26 kW | 584 sq ft | $2,568 | $4,342 |
Which Sibling Wattage & Trim Variants Belong to This GCL System Integration Technology Co Ltd Series?
Consolidated GCL System Integration Technology Co Ltd wattage variants sharing the GCL System Integration Technology Co Ltd GCL-M6/72GDF380 mechanical and cell layout.
| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| GCL System Integration Technology Co Ltd GCL-M6/72GDF375 | 375.0 W | 351.3 W | 48.33 V | 39.52 V | 18.66% |
| GCL System Integration Technology Co Ltd GCL-M6/72GDF380 | 380.0 W | 356.1 W | 48.53 V | 39.72 V | 18.91% |
| GCL System Integration Technology Co Ltd GCL-M6/72GDF385 | 385.0 W | 360.9 W | 48.73 V | 39.92 V | 19.15% |
How Many GCL System Integration Technology Co Ltd GCL-M6/72GDF380 Modules Fit in a Cold-Weather String?
NEC 690.7(A) winter string table preventing overvoltage trips on GCL System Integration Technology Co Ltd GCL-M6/72GDF380 (53.18 V at 14 F).
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 54.51 V | 11 panels | 599.6 V | 18 panels |
| -10 C (14 F) | 53.18 V | 11 panels | 585.0 V | 18 panels |
| 0 C (32 F) | 51.85 V | 11 panels | 570.4 V | 19 panels |
| 25 C (77 F STC) | 48.53 V | 12 panels | 582.4 V | 20 panels |
Which Cross-Brand Solar Modules Compare Closest to GCL System Integration Technology Co Ltd GCL-M6/72GDF380?
Competing CEC solar panels closest to GCL System Integration Technology Co Ltd GCL-M6/72GDF380 in nameplate wattage and Voc, starting with Bluesun Solar Energy Tech CoLtd BSM380M-72.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| Bluesun Solar Energy Tech CoLtd BSM380M-72 Bluesun Solar Energy Tech CoLtd |
380.0 W | Tie (0 W) | 48.67 V | 19.59% | 92.0% |
| Caterpillar Inc PVC380MP03H Caterpillar Inc |
380.0 W | Tie (0 W) | 49.0 V | 19.63% | 94.1% |
| Crossroads Solar Crossroads Solar 380 Crossroads Solar |
380.0 W | Tie (0 W) | 49.0 V | 18.63% | 92.2% |
| Caterpillar Inc PVC380MP03 Caterpillar Inc |
380.0 W | Tie (0 W) | 49.03 V | 20.21% | 93.5% |
What Are the Design Limits and Best-Fit Uses for GCL System Integration Technology Co Ltd GCL-M6/72GDF380?
Evaluate GCL System Integration Technology Co Ltd GCL-M6/72GDF380 (380.0 W STC, 48.53 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), GCL System Integration Technology Co Ltd GCL-M6/72GDF380 reaches 54.51 V per panel—exceeding 11 panels in series voids 600 V inverter warranties.
- Footprint constraint: 22 panels for an 8 kW build require 476 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 22 panels (476 sq ft).
- 2026 tax credit baseline: cash residential installs of GCL System Integration Technology Co Ltd GCL-M6/72GDF380 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
GCL System Integration Technology Co Ltd GCL-M6/72GDF380 8 kW Residential Fit
Needs 22 modules (476 sq ft) with a 20 A string OCPD, offsetting ~$2,092/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 11 panels (-10 C) or 11 panels (-20 C), or compare Bluesun Solar Energy Tech CoLtd BSM380M-72.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 356.1 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for GCL System Integration Technology Co Ltd GCL-M6/72GDF380 by GCL System Integration Technology Co Ltd grounded in CEC test data and NEC 690.7/690.8 limits.
What fuse or breaker size does NEC 690.8 require for GCL System Integration Technology Co Ltd GCL-M6/72GDF380?
Multiplying GCL System Integration Technology Co Ltd GCL-M6/72GDF380's 10.04 A short-circuit current by 1.56 equals 15.66 A minimum ampacity, requiring at least a 20 A overcurrent fuse or breaker.
Can GCL System Integration Technology Co Ltd GCL-M6/72GDF380 pair with microinverters instead of a 600 V string inverter?
Yes—if the microinverter DC input ceiling exceeds 53.18 V cold Voc at 14 F and handles 10.04 A Isc; string inverters cap GCL System Integration Technology Co Ltd GCL-M6/72GDF380 at 11 panels on 600 V.
Is GCL System Integration Technology Co Ltd GCL-M6/72GDF380 eligible for the 30% federal 25D solar credit in 2026?
No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of GCL System Integration Technology Co Ltd GCL-M6/72GDF380 rely on utility bill offset (~$2,092/yr at 8 kW) rather than 25D.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)