GCL System Integration Technology Co Ltd GCL-M6/72DH380 is a 380.0 W STC (352.0 W PTC) Mono-c-Si solar module ranking #11,043 of 21,677 CEC listings (below all-CEC median; higher than 47.6% of peers). It delivers 19.19% efficiency, 48.53 V Voc at 25 C, and 53.78 V cold Voc at -10 C (11 panels max per 600 V string).
- STC Wattage
- 380.0 W
- PTC Wattage
- 352.0 W
- Voc @ 25C
- 48.53 V
- Efficiency
- 19.19%
How Does GCL System Integration Technology Co Ltd GCL-M6/72DH380 Compare Against Peer CEC Listings?
CEC rank, roof space requirements, and NEC 690.7/690.8 limits for GCL System Integration Technology Co Ltd GCL-M6/72DH380 (Mono-c-Si) residential solar systems.
Homeowners evaluating GCL System Integration Technology Co Ltd GCL-M6/72DH380 need 16 panels for 6 kW or 22 panels (469 sq ft) for an 8 kW array—useful on tight dormer roofs or battery cabins, though 8 kW requires 22 panels (469 sq ft). Under NEC 690.7(A), beta_Voc (-0.309%/C) pushes open-circuit voltage to 53.78 V at 14 F and 55.28 V at -4 F. Monofacial backsheet sealing targets flush dark shingle rooftop mounts.
Where Does GCL System Integration Technology Co Ltd GCL-M6/72DH380 Fall Across Listed CEC Models?
Comparison of GCL System Integration Technology Co Ltd GCL-M6/72DH380 (380.0 W STC) against all 21,677 California Energy Commission certified photovoltaic modules.
What Dataset Percentiles Define GCL System Integration Technology Co Ltd GCL-M6/72DH380?
Relative ranking of GCL System Integration Technology Co Ltd GCL-M6/72DH380 across nameplate watts, 92.6% PTC thermal ratio, and module aperture efficiency.
What Do the Dataset Ranks Show for GCL System Integration Technology Co Ltd GCL-M6/72DH380?
Summary of GCL System Integration Technology Co Ltd GCL-M6/72DH380 output rank, 8 kW array size (22 panels), efficiency rating, and 600 V string limit.
380.0 W STC · Higher Than 47.6%
380.0 W STC (-5.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.
19.19% Aperture Efficiency
Power density 191.9 W/m2 (0.72 percentage points below 19.91% CEC median). PTC/STC ratio: 92.6% (rank #11,981).
11 Panels Max @ -10 C (600 V)
Cold Voc reaches 53.78 V at -10 C (591.6 V string) and 55.28 V at -20 C (10 max).
22 Panels = 8,360 W STC
Occupies 43.6 m2 (469 sq ft) producing 7,744 W PTC; NEC 690.8 OCPD floor is 15.66 A (20 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 48.53 * (1 + (-0.309/100) * (-10 - 25)) = 53.78 V | OCPD = 1.56 * 10.04 = 15.66 A
Inputs from CEC Modules.csv for GCL System Integration Technology Co Ltd GCL-M6/72DH380: Voc=48.53 V, beta_Voc=-0.309%/C, Isc=10.04 A, STC=380.0 W, Area=1.98 m2.
Result: 11 panels max on 600 V (591.6 V); 22 panels for 8 kW (469 sq ft).
What Are the Published CEC Specifications for GCL System Integration Technology Co Ltd GCL-M6/72DH380?
Complete CEC test sheet for GCL System Integration Technology Co Ltd GCL-M6/72DH380 including Isc (10.04 A), Voc (48.53 V), and thermal temperature coefficients.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 380.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 352.0 W (92.6% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 48.53 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 10.04 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 39.72 V / 9.57 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.309 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 19.19% (1.98 m2) | Array roof footprint density |
| Cell Count & Technology | 72 cells (Mono-c-Si) | Monofacial backsheet |
How Many GCL System Integration Technology Co Ltd GCL-M6/72DH380 Panels Build a 6 kW, 8 kW, or 10 kW Array?
Residential array count and annual electric bill savings at 18.54 c/kWh US avg vs. California tariffs using GCL System Integration Technology Co Ltd GCL-M6/72DH380.
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 16 | 6.08 kW | 341 sq ft | $1,522 | $2,573 |
| 8 kW Class | 22 | 8.36 kW | 469 sq ft | $2,092 | $3,538 |
| 10 kW Class | 27 | 10.26 kW | 575 sq ft | $2,568 | $4,342 |
Which Sibling Wattage & Trim Variants Belong to This GCL System Integration Technology Co Ltd Series?
Related GCL System Integration Technology Co Ltd power steps and black/silver trims consolidated into this GCL System Integration Technology Co Ltd GCL-M6/72DH380 series guide.
| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| GCL System Integration Technology Co Ltd GCL-M6/72DH375 | 375.0 W | 347.3 W | 48.33 V | 39.52 V | 18.94% |
| GCL System Integration Technology Co Ltd GCL-M6/72DH380 | 380.0 W | 352.0 W | 48.53 V | 39.72 V | 19.19% |
| GCL System Integration Technology Co Ltd GCL-M6/72DH385 | 385.0 W | 356.8 W | 48.73 V | 39.92 V | 19.44% |
How Many GCL System Integration Technology Co Ltd GCL-M6/72DH380 Modules Fit in a Cold-Weather String?
Verify freezing-morning voltage rise for GCL System Integration Technology Co Ltd GCL-M6/72DH380 (48.53 V STC) before wiring 600 V or 1,000 V strings.
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 55.28 V | 10 panels | 552.8 V | 18 panels |
| -10 C (14 F) | 53.78 V | 11 panels | 591.6 V | 18 panels |
| 0 C (32 F) | 52.28 V | 11 panels | 575.1 V | 19 panels |
| 25 C (77 F STC) | 48.53 V | 12 panels | 582.4 V | 20 panels |
Which Cross-Brand Solar Modules Compare Closest to GCL System Integration Technology Co Ltd GCL-M6/72DH380?
Four comparable CEC modules such as Bluesun Solar Energy Tech CoLtd BSM380M-72 (380.0 W) for side-by-side solar quote checks.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| Bluesun Solar Energy Tech CoLtd BSM380M-72 Bluesun Solar Energy Tech CoLtd |
380.0 W | Tie (0 W) | 48.67 V | 19.59% | 92.0% |
| Caterpillar Inc PVC380MP03H Caterpillar Inc |
380.0 W | Tie (0 W) | 49.0 V | 19.63% | 94.1% |
| Crossroads Solar Crossroads Solar 380 Crossroads Solar |
380.0 W | Tie (0 W) | 49.0 V | 18.63% | 92.2% |
| Caterpillar Inc PVC380MP03 Caterpillar Inc |
380.0 W | Tie (0 W) | 49.03 V | 20.21% | 93.5% |
What Are the Design Limits and Best-Fit Uses for GCL System Integration Technology Co Ltd GCL-M6/72DH380?
Evaluate GCL System Integration Technology Co Ltd GCL-M6/72DH380 (380.0 W STC, 48.53 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), GCL System Integration Technology Co Ltd GCL-M6/72DH380 reaches 55.28 V per panel—exceeding 10 panels in series voids 600 V inverter warranties.
- Footprint constraint: 22 panels for an 8 kW build require 469 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 22 panels (469 sq ft).
- 2026 tax credit baseline: cash residential installs of GCL System Integration Technology Co Ltd GCL-M6/72DH380 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
GCL System Integration Technology Co Ltd GCL-M6/72DH380 8 kW Residential Fit
Needs 22 modules (469 sq ft) with a 20 A string OCPD, offsetting ~$2,092/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 11 panels (-10 C) or 10 panels (-20 C), or compare Bluesun Solar Energy Tech CoLtd BSM380M-72.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 352.0 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for GCL System Integration Technology Co Ltd GCL-M6/72DH380 by GCL System Integration Technology Co Ltd grounded in CEC test data and NEC 690.7/690.8 limits.
Why is GCL System Integration Technology Co Ltd GCL-M6/72DH380 PTC wattage (352.0 W) lower than STC (380.0 W)?
Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 352.0 W PTC (92.6% retention) across GCL System Integration Technology Co Ltd GCL-M6/72DH380's 1.98 m2 aperture.
Who should skip GCL System Integration Technology Co Ltd GCL-M6/72DH380 on a complex residential roof?
Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 22 GCL System Integration Technology Co Ltd GCL-M6/72DH380 panels (469 sq ft) leave unusable roof gaps vs. Bluesun Solar Energy Tech CoLtd BSM380M-72.
What is the 1,000 V commercial string limit for GCL System Integration Technology Co Ltd GCL-M6/72DH380?
On 1,000 V commercial inverters at -10 C (53.78 V cold Voc), GCL System Integration Technology Co Ltd GCL-M6/72DH380 fits up to 18 panels per series string.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)