Manufacturer: First Solar Inc Registry: CEC Verified Engineering Specification

First Solar Inc FS-7515A-TR1 is a 515.0 W STC (478.9 W PTC) CdTe solar module ranking #4,316 of 21,677 CEC listings (top 20.2%; higher than 79.8% of peers). It delivers 18.39% efficiency, 225.0 V Voc at 25 C, and 246.42 V cold Voc at -10 C (2 panels max per 600 V string).

STC Wattage
515.0 W
PTC Wattage
478.9 W
Voc @ 25C
225.0 V
Efficiency
18.39%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does First Solar Inc FS-7515A-TR1 Compare Against Peer CEC Listings?

Solar engineering breakdown for First Solar Inc FS-7515A-TR1: PTC thermal retention, roof footprint, and cold Voc string bounds.

Across 131 CdTe listings from First Solar Inc and peers, First Solar Inc FS-7515A-TR1 stands 70.0 W above the 445.0 W CdTe median and strong 93.0% PTC-to-STC heat retention (#9,879 of 21,677). Sizing 6 kW (12 panels) to 10 kW (20 panels) yields $1,547-$2,578/yr in baseline US bill offset. Higher 225.0 V open-circuit voltage caps 600 V residential strings at 2 panels at 14 F (-10 C).

Where Does First Solar Inc FS-7515A-TR1 Fall Across Listed CEC Models?

Distribution marker showing First Solar Inc FS-7515A-TR1 (515.0 W) relative to the 385.0 W all-CEC solar panel median.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where First Solar Inc FS-7515A-TR1 (515.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCFirst Solar Inc FS: 515.0 W

What Dataset Percentiles Define First Solar Inc FS-7515A-TR1?

Dataset percentiles tracking First Solar Inc FS-7515A-TR1 power output, thermal retention ratio, and aperture efficiency against 21,677 models.

First Solar Inc FS-7515A-TR1 Engineering BenchmarksPercentile comparison of First Solar Inc FS-7515A-TR1 wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage515.0 WPTC/STC Retention93.0%Module Efficiency18.39%

What Do the Dataset Ranks Show for First Solar Inc FS-7515A-TR1?

Benchmark highlights for First Solar Inc FS-7515A-TR1 covering STC output, efficiency, 8 kW footprint, and OCPD breaker size.

Rank #4,316 / 21,677

Top 20.2% STC Output

515.0 W STC (+130.0 W vs all-CEC median) vs 445.0 W CdTe median.

Eff #14,533

18.39% Aperture Efficiency

Power density 183.9 W/m2 (1.52 percentage points below 19.91% CEC median). PTC/STC ratio: 93.0% (rank #9,879).

NEC 690.7 Limit

2 Panels Max @ -10 C (600 V)

Cold Voc reaches 246.42 V at -10 C (492.8 V string) and 252.54 V at -20 C (2 max).

8 kW Reference Array

16 Panels = 8,240 W STC

Occupies 44.8 m2 (482 sq ft) producing 7,662 W PTC; NEC 690.8 OCPD floor is 4.73 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 225.0 * (1 + (-0.272/100) * (-10 - 25)) = 246.42 V | OCPD = 1.56 * 3.03 = 4.73 A

Inputs from CEC Modules.csv for First Solar Inc FS-7515A-TR1: Voc=225.0 V, beta_Voc=-0.272%/C, Isc=3.03 A, STC=515.0 W, Area=2.8 m2.

Result: 2 panels max on 600 V (492.8 V); 16 panels for 8 kW (482 sq ft).

What Are the Published CEC Specifications for First Solar Inc FS-7515A-TR1?

Official CEC datasheet figures for First Solar Inc FS-7515A-TR1 (CdTe) used in utility interconnection and permit reviews. Data intervals combine current 2025 federal utility and BLS wage releases with verified state electrical board rosters.

Official California Energy Commission (NREL SAM) test parameters for First Solar Inc FS-7515A-TR1.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 515.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 478.9 W (93.0% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 225.0 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 3.03 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 184.3 V / 2.8 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.272 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 18.39% (2.8 m2) Array roof footprint density
Cell Count & Technology 268 cells (CdTe) Monofacial backsheet

How Many First Solar Inc FS-7515A-TR1 Panels Build a 6 kW, 8 kW, or 10 kW Array?

How many First Solar Inc FS-7515A-TR1 modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 12 6.18 kW 362 sq ft $1,547 $2,616
8 kW Class 16 8.24 kW 482 sq ft $2,062 $3,487
10 kW Class 20 10.3 kW 603 sq ft $2,578 $4,359

How Many First Solar Inc FS-7515A-TR1 Modules Fit in a Cold-Weather String?

NEC 690.7(A) winter string table preventing overvoltage trips on First Solar Inc FS-7515A-TR1 (246.42 V at 14 F).

Computed from Voc=225.0V and beta_Voc=-0.272%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 252.54 V 2 panels 505.1 V 3 panels
-10 C (14 F) 246.42 V 2 panels 492.8 V 4 panels
0 C (32 F) 240.3 V 2 panels 480.6 V 4 panels
25 C (77 F STC) 225.0 V 2 panels 450.0 V 4 panels

Which Cross-Brand Solar Modules Compare Closest to First Solar Inc FS-7515A-TR1?

Competing CEC solar panels closest to First Solar Inc FS-7515A-TR1 in nameplate wattage and Voc, starting with CSI Solar Co Ltd CS3Y-505MS.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
CSI Solar Co Ltd CS3Y-505MS
CSI Solar Co Ltd
505.0 W -10.0 W 53.9 V 22.05% 93.7%
Boviet Solar Technology Co Ltd BVM7612M-520-H-HC
Boviet Solar Technology Co Ltd
520.0 W +5.0 W 49.39 V 20.04% 93.8%
Bila Solar Inc BF510J-12X12UW
Bila Solar Inc
510.0 W -5.0 W 49.14 V 18.96% 93.2%
Bila Solar Inc DF510J-12X12UW
Bila Solar Inc
510.0 W -5.0 W 49.1 V 18.96% 93.6%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for First Solar Inc FS-7515A-TR1?

Evaluate First Solar Inc FS-7515A-TR1 (515.0 W STC, 225.0 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), First Solar Inc FS-7515A-TR1 reaches 252.54 V per panel—exceeding 2 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 16 panels for an 8 kW build require 482 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 16 panels (482 sq ft) for an 8 kW array.
  • 2026 tax credit baseline: cash residential installs of First Solar Inc FS-7515A-TR1 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

First Solar Inc FS-7515A-TR1 8 kW Residential Fit

Needs 16 modules (482 sq ft) with a 15 A string OCPD, offsetting ~$2,062/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 2 panels (-10 C) or 2 panels (-20 C), or compare CSI Solar Co Ltd CS3Y-505MS.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 478.9 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for First Solar Inc FS-7515A-TR1 by First Solar Inc grounded in CEC test data and NEC 690.7/690.8 limits.

What fuse or breaker size does NEC 690.8 require for First Solar Inc FS-7515A-TR1?

Multiplying First Solar Inc FS-7515A-TR1's 3.03 A short-circuit current by 1.56 equals 4.73 A minimum ampacity, requiring at least a 15 A overcurrent fuse or breaker.

Can First Solar Inc FS-7515A-TR1 pair with microinverters instead of a 600 V string inverter?

Yes—if the microinverter DC input ceiling exceeds 246.42 V cold Voc at 14 F and handles 3.03 A Isc; string inverters cap First Solar Inc FS-7515A-TR1 at 2 panels on 600 V.

Is First Solar Inc FS-7515A-TR1 eligible for the 30% federal 25D solar credit in 2026?

No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of First Solar Inc FS-7515A-TR1 rely on utility bill offset (~$2,062/yr at 8 kW) rather than 25D.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.