Bila Solar Inc BF510J-12X12UW is a 510.0 W STC (475.4 W PTC) Mono-c-Si solar module ranking #4,386 of 21,677 CEC listings (top 20.5%; higher than 79.5% of peers). It delivers 18.96% efficiency, 49.14 V Voc at 25 C, and 53.54 V cold Voc at -10 C (11 panels max per 600 V string).
- STC Wattage
- 510.0 W
- PTC Wattage
- 475.4 W
- Voc @ 25C
- 49.14 V
- Efficiency
- 18.96%
How Does Bila Solar Inc BF510J-12X12UW Compare Against Peer CEC Listings?
How Bila Solar Inc Bila Solar Inc BF510J-12X12UW handles rooftop heat (475.4 W PTC), 8 kW sizing, and cold winter string voltage.
Bila Solar Inc builds the Bila Solar Inc BF510J-12X12UW (Mono-c-Si) as a modern high-density residential and light-commercial module delivering 189.6 W/m2 (0.95 percentage points below 19.91% CEC median). Compared against AXITEC AC-520MH/144VB (520.0 W), this model holds strong 93.2% PTC-to-STC heat retention (#8,924 of 21,677). Higher 49.14 V open-circuit voltage caps 600 V residential strings at 11 panels at 14 F (-10 C), while NEC 690.8 sets a 21.0 A overcurrent floor served by a 25 A breaker.
Where Does Bila Solar Inc BF510J-12X12UW Fall Across Listed CEC Models?
Where Bila Solar Inc BF510J-12X12UW (510.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.
What Dataset Percentiles Define Bila Solar Inc BF510J-12X12UW?
Percentile placement of Bila Solar Inc BF510J-12X12UW across power density (189.6 W/m2), thermal retention, and nameplate STC wattage.
What Do the Dataset Ranks Show for Bila Solar Inc BF510J-12X12UW?
Four critical engineering numbers homeowners and solar installers check first when reviewing Bila Solar Inc BF510J-12X12UW specifications. Compare thermal ratings, overcurrent protection caps, and continuous load headroom carefully before expanding an existing home service panel.
Top 20.5% STC Output
510.0 W STC (+125.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.
18.96% Aperture Efficiency
Power density 189.6 W/m2 (0.95 percentage points below 19.91% CEC median). PTC/STC ratio: 93.2% (rank #8,924).
11 Panels Max @ -10 C (600 V)
Cold Voc reaches 53.54 V at -10 C (588.9 V string) and 54.8 V at -20 C (10 max).
16 Panels = 8,160 W STC
Occupies 43.0 m2 (463 sq ft) producing 7,606 W PTC; NEC 690.8 OCPD floor is 21.0 A (25 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 49.14 * (1 + (-0.256/100) * (-10 - 25)) = 53.54 V | OCPD = 1.56 * 13.46 = 21.0 A
Inputs from CEC Modules.csv for Bila Solar Inc BF510J-12X12UW: Voc=49.14 V, beta_Voc=-0.256%/C, Isc=13.46 A, STC=510.0 W, Area=2.69 m2.
Result: 11 panels max on 600 V (588.9 V); 16 panels for 8 kW (463 sq ft).
What Are the Published CEC Specifications for Bila Solar Inc BF510J-12X12UW?
Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for Bila Solar Inc BF510J-12X12UW.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 510.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 475.4 W (93.2% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 49.14 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 13.46 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 41.81 V / 12.21 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.256 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 18.96% (2.69 m2) | Array roof footprint density |
| Cell Count & Technology | 72 cells (Mono-c-Si) | Monofacial backsheet |
How Many Bila Solar Inc BF510J-12X12UW Panels Build a 6 kW, 8 kW, or 10 kW Array?
Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using Bila Solar Inc BF510J-12X12UW (510.0 W).
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 12 | 6.12 kW | 347 sq ft | $1,532 | $2,590 |
| 8 kW Class | 16 | 8.16 kW | 463 sq ft | $2,042 | $3,454 |
| 10 kW Class | 20 | 10.2 kW | 579 sq ft | $2,553 | $4,317 |
Which Sibling Wattage & Trim Variants Belong to This Bila Solar Inc Series?
All closely matched Bila Solar Inc wattages and cosmetic trims sharing the Bila Solar Inc BF510J-12X12UW architecture. Use these verified dataset benchmarks alongside a licensed electrician load calculation to compare residential upgrade bids with confidence.
| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| Bila Solar Inc BF500J-12X12UW | 500.0 W | 465.8 W | 48.74 V | 41.35 V | 18.59% |
| Bila Solar Inc BF505J-12X12UW | 505.0 W | 470.6 W | 48.94 V | 41.58 V | 18.77% |
| Bila Solar Inc BF510J-12X12UW | 510.0 W | 475.4 W | 49.14 V | 41.81 V | 18.96% |
| Bila Solar Inc BF515J-12X12UW | 515.0 W | 480.1 W | 49.34 V | 42.06 V | 19.14% |
| Bila Solar Inc BF520J-12X12UW | 520.0 W | 484.9 W | 49.54 V | 42.26 V | 19.33% |
How Many Bila Solar Inc BF510J-12X12UW Modules Fit in a Cold-Weather String?
Maximum series module counts for Bila Solar Inc BF510J-12X12UW from 25 C down to -20 C (-4 F) under NEC 690.7.
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 54.8 V | 10 panels | 548.0 V | 18 panels |
| -10 C (14 F) | 53.54 V | 11 panels | 588.9 V | 18 panels |
| 0 C (32 F) | 52.28 V | 11 panels | 575.1 V | 19 panels |
| 25 C (77 F STC) | 49.14 V | 12 panels | 589.7 V | 20 panels |
Which Cross-Brand Solar Modules Compare Closest to Bila Solar Inc BF510J-12X12UW?
Alternative CEC solar modules from competing brands near Bila Solar Inc BF510J-12X12UW (510.0 W), including AXITEC AC-520MH/144VB.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| AXITEC AC-520MH/144VB AXITEC |
520.0 W | +10.0 W | 49.0 V | 20.31% | 93.7% |
| ELITE Solar ET-M772BH520BB ELITE Solar |
520.0 W | +10.0 W | 49.0 V | 20.31% | 93.7% |
| Chint New Energy Technology Co Ltd CHSM72M-HC-520 Chint New Energy Technology Co Ltd |
520.0 W | +10.0 W | 48.9 V | 20.97% | 92.5% |
| Boviet Solar Technology Co Ltd BVM7612M-520-H-HC Boviet Solar Technology Co Ltd |
520.0 W | +10.0 W | 49.39 V | 20.04% | 93.8% |
What Are the Design Limits and Best-Fit Uses for Bila Solar Inc BF510J-12X12UW?
Evaluate Bila Solar Inc BF510J-12X12UW (510.0 W STC, 49.14 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), Bila Solar Inc BF510J-12X12UW reaches 54.8 V per panel—exceeding 10 panels in series voids 600 V inverter warranties.
- Footprint constraint: 16 panels for an 8 kW build require 463 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 16 panels (463 sq ft) for an 8 kW array.
- 2026 tax credit baseline: cash residential installs of Bila Solar Inc BF510J-12X12UW carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
Bila Solar Inc BF510J-12X12UW 8 kW Residential Fit
Needs 16 modules (463 sq ft) with a 25 A string OCPD, offsetting ~$2,042/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 11 panels (-10 C) or 10 panels (-20 C), or compare AXITEC AC-520MH/144VB.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 475.4 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for Bila Solar Inc BF510J-12X12UW by Bila Solar Inc grounded in CEC test data and NEC 690.7/690.8 limits.
What fuse or breaker size does NEC 690.8 require for Bila Solar Inc BF510J-12X12UW?
Multiplying Bila Solar Inc BF510J-12X12UW's 13.46 A short-circuit current by 1.56 equals 21.0 A minimum ampacity, requiring at least a 25 A overcurrent fuse or breaker.
Can Bila Solar Inc BF510J-12X12UW pair with microinverters instead of a 600 V string inverter?
Yes—if the microinverter DC input ceiling exceeds 53.54 V cold Voc at 14 F and handles 13.46 A Isc; string inverters cap Bila Solar Inc BF510J-12X12UW at 11 panels on 600 V.
Is Bila Solar Inc BF510J-12X12UW eligible for the 30% federal 25D solar credit in 2026?
No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of Bila Solar Inc BF510J-12X12UW rely on utility bill offset (~$2,042/yr at 8 kW) rather than 25D.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)