First Solar Inc FS-7515A-FT1 is a 515.0 W STC (478.9 W PTC) CdTe solar module ranking #4,316 of 21,677 CEC listings (top 20.2%; higher than 79.8% of peers). It delivers 18.39% efficiency, 225.0 V Voc at 25 C, and 246.42 V cold Voc at -10 C (2 panels max per 600 V string).
- STC Wattage
- 515.0 W
- PTC Wattage
- 478.9 W
- Voc @ 25C
- 225.0 V
- Efficiency
- 18.39%
How Does First Solar Inc FS-7515A-FT1 Compare Against Peer CEC Listings?
Solar engineering breakdown for First Solar Inc FS-7515A-FT1: PTC thermal retention, roof footprint, and cold Voc string bounds.
Measured at 515.0 W STC and 478.9 W PTC, First Solar Inc FS-7515A-FT1 sits +130.0 W vs all-CEC median (top 20.2%; higher than 79.8% of peers) among 21,677 listed modules. Power density reaches 183.9 W/m2 (1.52 percentage points below 19.91% CEC median). Higher 225.0 V open-circuit voltage caps 600 V residential strings at 2 panels at 14 F (-10 C), whereas 1,000 V commercial inverters handle up to 4 panels in series. Alternative peer CSI Solar Co Ltd CS3Y-505MS rates 505.0 W.
Where Does First Solar Inc FS-7515A-FT1 Fall Across Listed CEC Models?
Distribution marker showing First Solar Inc FS-7515A-FT1 (515.0 W) relative to the 385.0 W all-CEC solar panel median.
What Dataset Percentiles Define First Solar Inc FS-7515A-FT1?
Dataset percentiles tracking First Solar Inc FS-7515A-FT1 power output, thermal retention ratio, and aperture efficiency against 21,677 models.
What Do the Dataset Ranks Show for First Solar Inc FS-7515A-FT1?
Benchmark highlights for First Solar Inc FS-7515A-FT1 covering STC output, efficiency, 8 kW footprint, and OCPD breaker size.
Top 20.2% STC Output
515.0 W STC (+130.0 W vs all-CEC median) vs 445.0 W CdTe median.
18.39% Aperture Efficiency
Power density 183.9 W/m2 (1.52 percentage points below 19.91% CEC median). PTC/STC ratio: 93.0% (rank #9,879).
2 Panels Max @ -10 C (600 V)
Cold Voc reaches 246.42 V at -10 C (492.8 V string) and 252.54 V at -20 C (2 max).
16 Panels = 8,240 W STC
Occupies 44.8 m2 (482 sq ft) producing 7,662 W PTC; NEC 690.8 OCPD floor is 4.73 A (15 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 225.0 * (1 + (-0.272/100) * (-10 - 25)) = 246.42 V | OCPD = 1.56 * 3.03 = 4.73 A
Inputs from CEC Modules.csv for First Solar Inc FS-7515A-FT1: Voc=225.0 V, beta_Voc=-0.272%/C, Isc=3.03 A, STC=515.0 W, Area=2.8 m2.
Result: 2 panels max on 600 V (492.8 V); 16 panels for 8 kW (482 sq ft).
What Are the Published CEC Specifications for First Solar Inc FS-7515A-FT1?
Official CEC datasheet figures for First Solar Inc FS-7515A-FT1 (CdTe) used in utility interconnection and permit reviews. Data intervals combine current 2025 federal utility and BLS wage releases with verified state electrical board rosters.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 515.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 478.9 W (93.0% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 225.0 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 3.03 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 184.3 V / 2.8 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.272 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 18.39% (2.8 m2) | Array roof footprint density |
| Cell Count & Technology | 268 cells (CdTe) | Monofacial backsheet |
How Many First Solar Inc FS-7515A-FT1 Panels Build a 6 kW, 8 kW, or 10 kW Array?
How many First Solar Inc FS-7515A-FT1 modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 12 | 6.18 kW | 362 sq ft | $1,547 | $2,616 |
| 8 kW Class | 16 | 8.24 kW | 482 sq ft | $2,062 | $3,487 |
| 10 kW Class | 20 | 10.3 kW | 603 sq ft | $2,578 | $4,359 |
How Many First Solar Inc FS-7515A-FT1 Modules Fit in a Cold-Weather String?
NEC 690.7(A) winter string table preventing overvoltage trips on First Solar Inc FS-7515A-FT1 (246.42 V at 14 F).
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 252.54 V | 2 panels | 505.1 V | 3 panels |
| -10 C (14 F) | 246.42 V | 2 panels | 492.8 V | 4 panels |
| 0 C (32 F) | 240.3 V | 2 panels | 480.6 V | 4 panels |
| 25 C (77 F STC) | 225.0 V | 2 panels | 450.0 V | 4 panels |
Which Cross-Brand Solar Modules Compare Closest to First Solar Inc FS-7515A-FT1?
Competing CEC solar panels closest to First Solar Inc FS-7515A-FT1 in nameplate wattage and Voc, starting with CSI Solar Co Ltd CS3Y-505MS.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| CSI Solar Co Ltd CS3Y-505MS CSI Solar Co Ltd |
505.0 W | -10.0 W | 53.9 V | 22.05% | 93.7% |
| Boviet Solar Technology Co Ltd BVM7612M-520-H-HC Boviet Solar Technology Co Ltd |
520.0 W | +5.0 W | 49.39 V | 20.04% | 93.8% |
| Bila Solar Inc BF510J-12X12UW Bila Solar Inc |
510.0 W | -5.0 W | 49.14 V | 18.96% | 93.2% |
| Bila Solar Inc DF510J-12X12UW Bila Solar Inc |
510.0 W | -5.0 W | 49.1 V | 18.96% | 93.6% |
What Are the Design Limits and Best-Fit Uses for First Solar Inc FS-7515A-FT1?
Evaluate First Solar Inc FS-7515A-FT1 (515.0 W STC, 225.0 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), First Solar Inc FS-7515A-FT1 reaches 252.54 V per panel—exceeding 2 panels in series voids 600 V inverter warranties.
- Footprint constraint: 16 panels for an 8 kW build require 482 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 16 panels (482 sq ft) for an 8 kW array.
- 2026 tax credit baseline: cash residential installs of First Solar Inc FS-7515A-FT1 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
First Solar Inc FS-7515A-FT1 8 kW Residential Fit
Needs 16 modules (482 sq ft) with a 15 A string OCPD, offsetting ~$2,062/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 2 panels (-10 C) or 2 panels (-20 C), or compare CSI Solar Co Ltd CS3Y-505MS.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 478.9 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for First Solar Inc FS-7515A-FT1 by First Solar Inc grounded in CEC test data and NEC 690.7/690.8 limits.
How many First Solar Inc FS-7515A-FT1 panels fit on a 600 V winter solar string?
At -10 C (14 F), First Solar Inc FS-7515A-FT1 cold Voc rises from 225.0 V to 246.42 V (beta_Voc -0.272%/C), capping a 600 V string at 2 panels (492.8 V).
How much roof area does an 8 kW array of First Solar Inc FS-7515A-FT1 need?
An 8 kW DC system uses 16 First Solar Inc FS-7515A-FT1 modules (8,240 W STC / 7,662 W PTC), covering roughly 482 sq ft and saving ~$2,062/yr at 18.54 c/kWh.
How does First Solar Inc FS-7515A-FT1 compare against CSI Solar Co Ltd CS3Y-505MS?
First Solar Inc FS-7515A-FT1 outputs 515.0 W STC (225.0 V Voc, rank #4,316 of 21,677), while CSI Solar Co Ltd CS3Y-505MS delivers 505.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)