Skip to main content
WireAndSun
Calculators
CEC PV Module

First Solar Inc FS-7510A-FT1 — CEC Solar Module Specifications

Manufacturer: First Solar Inc Registry: CEC Verified Engineering Specification

First Solar Inc FS-7510A-FT1 is a 510.0 W STC (474.1 W PTC) CdTe solar module ranking #4,386 of 21,677 CEC listings (top 20.5%; higher than 79.5% of peers). It delivers 18.21% efficiency, 224.5 V Voc at 25 C, and 245.87 V cold Voc at -10 C (2 panels max per 600 V string).

STC Wattage
510.0 W
PTC Wattage
474.1 W
Voc @ 25C
224.5 V
Efficiency
18.21%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does First Solar Inc FS-7510A-FT1 Compare Against Peer CEC Listings?

CEC rank, roof space requirements, and NEC 690.7/690.8 limits for First Solar Inc FS-7510A-FT1 (CdTe) residential solar systems.

First Solar Inc FS-7510A-FT1 delivers 182.1 W/m2 (1.70 percentage points below 19.91% CEC median) and strong 93.0% PTC-to-STC heat retention (#9,879 of 21,677), placing it as a modern high-density residential and light-commercial module well-proportioned for residential pitched roofs needing 16 panels (482 sq ft) for an 8 kW array. At -4 F (-20 C), string voltage climbs to 251.98 V per unit, capping 600 V circuits at 2 panels. Compare specs directly with CSI Solar Co Ltd CS3Y-505MS (505.0 W).

Where Does First Solar Inc FS-7510A-FT1 Fall Across Listed CEC Models?

Comparison of First Solar Inc FS-7510A-FT1 (510.0 W STC) against all 21,677 California Energy Commission certified photovoltaic modules.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where First Solar Inc FS-7510A-FT1 (510.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCFirst Solar Inc FS: 510.0 W

What Dataset Percentiles Define First Solar Inc FS-7510A-FT1?

Relative ranking of First Solar Inc FS-7510A-FT1 across nameplate watts, 93.0% PTC thermal ratio, and module aperture efficiency.

First Solar Inc FS-7510A-FT1 Engineering BenchmarksPercentile comparison of First Solar Inc FS-7510A-FT1 wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage510.0 WPTC/STC Retention93.0%Module Efficiency18.21%

What Do the Dataset Ranks Show for First Solar Inc FS-7510A-FT1?

Summary of First Solar Inc FS-7510A-FT1 output rank, 8 kW array size (16 panels), efficiency rating, and 600 V string limit.

Rank #4,386 / 21,677

Top 20.5% STC Output

510.0 W STC (+125.0 W vs all-CEC median) vs 445.0 W CdTe median.

Eff #14,805

18.21% Aperture Efficiency

Power density 182.1 W/m2 (1.70 percentage points below 19.91% CEC median). PTC/STC ratio: 93.0% (rank #9,879).

NEC 690.7 Limit

2 Panels Max @ -10 C (600 V)

Cold Voc reaches 245.87 V at -10 C (491.7 V string) and 251.98 V at -20 C (2 max).

8 kW Reference Array

16 Panels = 8,160 W STC

Occupies 44.8 m2 (482 sq ft) producing 7,586 W PTC; NEC 690.8 OCPD floor is 4.71 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 224.5 * (1 + (-0.272/100) * (-10 - 25)) = 245.87 V | OCPD = 1.56 * 3.02 = 4.71 A

Inputs from CEC Modules.csv for First Solar Inc FS-7510A-FT1: Voc=224.5 V, beta_Voc=-0.272%/C, Isc=3.02 A, STC=510.0 W, Area=2.8 m2.

Result: 2 panels max on 600 V (491.7 V); 16 panels for 8 kW (482 sq ft).

What Are the Published CEC Specifications for First Solar Inc FS-7510A-FT1?

Complete CEC test sheet for First Solar Inc FS-7510A-FT1 including Isc (3.02 A), Voc (224.5 V), and thermal temperature coefficients.

Official California Energy Commission (NREL SAM) test parameters for First Solar Inc FS-7510A-FT1.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 510.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 474.1 W (93.0% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 224.5 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 3.02 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 183.4 V / 2.78 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.272 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 18.21% (2.8 m2) Array roof footprint density
Cell Count & Technology 268 cells (CdTe) Monofacial backsheet

How Many First Solar Inc FS-7510A-FT1 Panels Build a 6 kW, 8 kW, or 10 kW Array?

Residential array count and annual electric bill savings at 18.54 c/kWh US avg vs. California tariffs using First Solar Inc FS-7510A-FT1.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 12 6.12 kW 362 sq ft $1,532 $2,590
8 kW Class 16 8.16 kW 482 sq ft $2,042 $3,454
10 kW Class 20 10.2 kW 603 sq ft $2,553 $4,317

How Many First Solar Inc FS-7510A-FT1 Modules Fit in a Cold-Weather String?

Verify freezing-morning voltage rise for First Solar Inc FS-7510A-FT1 (224.5 V STC) before wiring 600 V or 1,000 V strings.

Computed from Voc=224.5V and beta_Voc=-0.272%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 251.98 V 2 panels 504.0 V 3 panels
-10 C (14 F) 245.87 V 2 panels 491.7 V 4 panels
0 C (32 F) 239.77 V 2 panels 479.5 V 4 panels
25 C (77 F STC) 224.5 V 2 panels 449.0 V 4 panels

Which Cross-Brand Solar Modules Compare Closest to First Solar Inc FS-7510A-FT1?

Four comparable CEC modules such as CSI Solar Co Ltd CS3Y-505MS (505.0 W) for side-by-side solar quote checks.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
CSI Solar Co Ltd CS3Y-505MS
CSI Solar Co Ltd
505.0 W -5.0 W 53.9 V 22.05% 93.7%
Bila Solar Inc BF510J-12X12UW
Bila Solar Inc
510.0 W Tie (0 W) 49.14 V 18.96% 93.2%
Bila Solar Inc DF510J-12X12UW
Bila Solar Inc
510.0 W Tie (0 W) 49.1 V 18.96% 93.6%
Boviet Solar Technology Co Ltd BVM7612M-520-H-HC
Boviet Solar Technology Co Ltd
520.0 W +10.0 W 49.39 V 20.04% 93.8%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for First Solar Inc FS-7510A-FT1?

Evaluate First Solar Inc FS-7510A-FT1 (510.0 W STC, 224.5 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), First Solar Inc FS-7510A-FT1 reaches 251.98 V per panel—exceeding 2 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 16 panels for an 8 kW build require 482 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 16 panels (482 sq ft) for an 8 kW array.
  • 2026 tax credit baseline: cash residential installs of First Solar Inc FS-7510A-FT1 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

First Solar Inc FS-7510A-FT1 8 kW Residential Fit

Needs 16 modules (482 sq ft) with a 15 A string OCPD, offsetting ~$2,042/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 2 panels (-10 C) or 2 panels (-20 C), or compare CSI Solar Co Ltd CS3Y-505MS.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 474.1 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for First Solar Inc FS-7510A-FT1 by First Solar Inc grounded in CEC test data and NEC 690.7/690.8 limits.

How many First Solar Inc FS-7510A-FT1 panels fit on a 600 V winter solar string?

At -10 C (14 F), First Solar Inc FS-7510A-FT1 cold Voc rises from 224.5 V to 245.87 V (beta_Voc -0.272%/C), capping a 600 V string at 2 panels (491.7 V).

How much roof area does an 8 kW array of First Solar Inc FS-7510A-FT1 need?

An 8 kW DC system uses 16 First Solar Inc FS-7510A-FT1 modules (8,160 W STC / 7,586 W PTC), covering roughly 482 sq ft and saving ~$2,042/yr at 18.54 c/kWh.

How does First Solar Inc FS-7510A-FT1 compare against CSI Solar Co Ltd CS3Y-505MS?

First Solar Inc FS-7510A-FT1 outputs 510.0 W STC (224.5 V Voc, rank #4,386 of 21,677), while CSI Solar Co Ltd CS3Y-505MS delivers 505.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.