First Solar Inc FS-6480A-P-I is a 480.0 W STC (452.3 W PTC) CdTe solar module ranking #4,809 of 21,677 CEC listings (top 22.6%; higher than 77.4% of peers). It delivers 19.05% efficiency, 225.4 V Voc at 25 C, and 247.25 V cold Voc at -10 C (2 panels max per 600 V string).
- STC Wattage
- 480.0 W
- PTC Wattage
- 452.3 W
- Voc @ 25C
- 225.4 V
- Efficiency
- 19.05%
How Does First Solar Inc FS-6480A-P-I Compare Against Peer CEC Listings?
CEC rank, roof space requirements, and NEC 690.7/690.8 limits for First Solar Inc FS-6480A-P-I (CdTe) residential solar systems.
First Solar Inc FS-6480A-P-I delivers 190.5 W/m2 (0.86 percentage points below 19.91% CEC median) and strong 94.2% PTC-to-STC heat retention (#3,689 of 21,677), placing it as a modern high-density residential and light-commercial module well-proportioned for residential pitched roofs needing 17 panels (461 sq ft) for an 8 kW array. At -4 F (-20 C), string voltage climbs to 253.5 V per unit, capping 600 V circuits at 2 panels. Compare specs directly with Applied Materials Full Size Tandem Junction (458.0 W).
Where Does First Solar Inc FS-6480A-P-I Fall Across Listed CEC Models?
Comparison of First Solar Inc FS-6480A-P-I (480.0 W STC) against all 21,677 California Energy Commission certified photovoltaic modules.
What Dataset Percentiles Define First Solar Inc FS-6480A-P-I?
Relative ranking of First Solar Inc FS-6480A-P-I across nameplate watts, 94.2% PTC thermal ratio, and module aperture efficiency.
What Do the Dataset Ranks Show for First Solar Inc FS-6480A-P-I?
Summary of First Solar Inc FS-6480A-P-I output rank, 8 kW array size (17 panels), efficiency rating, and 600 V string limit.
Top 22.6% STC Output
480.0 W STC (+95.0 W vs all-CEC median) vs 445.0 W CdTe median.
19.05% Aperture Efficiency
Power density 190.5 W/m2 (0.86 percentage points below 19.91% CEC median). PTC/STC ratio: 94.2% (rank #3,689).
2 Panels Max @ -10 C (600 V)
Cold Voc reaches 247.25 V at -10 C (494.5 V string) and 253.5 V at -20 C (2 max).
17 Panels = 8,160 W STC
Occupies 42.8 m2 (461 sq ft) producing 7,689 W PTC; NEC 690.8 OCPD floor is 4.09 A (15 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 225.4 * (1 + (-0.277/100) * (-10 - 25)) = 247.25 V | OCPD = 1.56 * 2.62 = 4.09 A
Inputs from CEC Modules.csv for First Solar Inc FS-6480A-P-I: Voc=225.4 V, beta_Voc=-0.277%/C, Isc=2.62 A, STC=480.0 W, Area=2.52 m2.
Result: 2 panels max on 600 V (494.5 V); 17 panels for 8 kW (461 sq ft).
What Are the Published CEC Specifications for First Solar Inc FS-6480A-P-I?
Complete CEC test sheet for First Solar Inc FS-6480A-P-I including Isc (2.62 A), Voc (225.4 V), and thermal temperature coefficients.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 480.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 452.3 W (94.2% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 225.4 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 2.62 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 192.8 V / 2.49 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.277 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 19.05% (2.52 m2) | Array roof footprint density |
| Cell Count & Technology | 268 cells (CdTe) | Monofacial backsheet |
How Many First Solar Inc FS-6480A-P-I Panels Build a 6 kW, 8 kW, or 10 kW Array?
Residential array count and annual electric bill savings at 18.54 c/kWh US avg vs. California tariffs using First Solar Inc FS-6480A-P-I.
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 13 | 6.24 kW | 353 sq ft | $1,562 | $2,641 |
| 8 kW Class | 17 | 8.16 kW | 461 sq ft | $2,042 | $3,454 |
| 10 kW Class | 21 | 10.08 kW | 570 sq ft | $2,523 | $4,266 |
How Many First Solar Inc FS-6480A-P-I Modules Fit in a Cold-Weather String?
Verify freezing-morning voltage rise for First Solar Inc FS-6480A-P-I (225.4 V STC) before wiring 600 V or 1,000 V strings.
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 253.5 V | 2 panels | 507.0 V | 3 panels |
| -10 C (14 F) | 247.25 V | 2 panels | 494.5 V | 4 panels |
| 0 C (32 F) | 241.01 V | 2 panels | 482.0 V | 4 panels |
| 25 C (77 F STC) | 225.4 V | 2 panels | 450.8 V | 4 panels |
Which Cross-Brand Solar Modules Compare Closest to First Solar Inc FS-6480A-P-I?
Four comparable CEC modules such as Applied Materials Full Size Tandem Junction (458.0 W) for side-by-side solar quote checks.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| Applied Materials Full Size Tandem Junction Applied Materials |
458.0 W | -22.0 W | 280.0 V | 8.01% | 91.7% |
| Heliene 96M475 Heliene |
475.0 W | -5.0 W | 62.39 V | 18.85% | 90.5% |
| Heliene 96M460 Heliene |
460.0 W | -20.0 W | 61.79 V | 18.25% | 90.4% |
| CSI Solar Co Ltd CS3Y-480P CSI Solar Co Ltd |
480.0 W | Tie (0 W) | 52.8 V | 20.96% | 93.2% |
What Are the Design Limits and Best-Fit Uses for First Solar Inc FS-6480A-P-I?
Evaluate First Solar Inc FS-6480A-P-I (480.0 W STC, 225.4 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), First Solar Inc FS-6480A-P-I reaches 253.5 V per panel—exceeding 2 panels in series voids 600 V inverter warranties.
- Footprint constraint: 17 panels for an 8 kW build require 461 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 17 panels (461 sq ft) for an 8 kW array.
- 2026 tax credit baseline: cash residential installs of First Solar Inc FS-6480A-P-I carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
First Solar Inc FS-6480A-P-I 8 kW Residential Fit
Needs 17 modules (461 sq ft) with a 15 A string OCPD, offsetting ~$2,042/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 2 panels (-10 C) or 2 panels (-20 C), or compare Applied Materials Full Size Tandem Junction.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 452.3 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for First Solar Inc FS-6480A-P-I by First Solar Inc grounded in CEC test data and NEC 690.7/690.8 limits.
How many First Solar Inc FS-6480A-P-I panels fit on a 600 V winter solar string?
At -10 C (14 F), First Solar Inc FS-6480A-P-I cold Voc rises from 225.4 V to 247.25 V (beta_Voc -0.277%/C), capping a 600 V string at 2 panels (494.5 V).
How much roof area does an 8 kW array of First Solar Inc FS-6480A-P-I need?
An 8 kW DC system uses 17 First Solar Inc FS-6480A-P-I modules (8,160 W STC / 7,689 W PTC), covering roughly 461 sq ft and saving ~$2,042/yr at 18.54 c/kWh.
How does First Solar Inc FS-6480A-P-I compare against Applied Materials Full Size Tandem Junction?
First Solar Inc FS-6480A-P-I outputs 480.0 W STC (225.4 V Voc, rank #4,809 of 21,677), while Applied Materials Full Size Tandem Junction delivers 458.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)