First Solar Inc FS-6475A-P is a 475.0 W STC (447.5 W PTC) CdTe solar module ranking #4,892 of 21,677 CEC listings (top 22.9%; higher than 77.1% of peers). It delivers 18.85% efficiency, 224.8 V Voc at 25 C, and 246.59 V cold Voc at -10 C (2 panels max per 600 V string).
- STC Wattage
- 475.0 W
- PTC Wattage
- 447.5 W
- Voc @ 25C
- 224.8 V
- Efficiency
- 18.85%
How Does First Solar Inc FS-6475A-P Compare Against Peer CEC Listings?
Engineering position of First Solar Inc FS-6475A-P (475.0 W STC) vs. Applied Materials Full Size Tandem Junction across 131 CEC CdTe solar modules.
Built with 268 CdTe cells, First Solar Inc FS-6475A-P pairs strong 94.2% PTC-to-STC heat retention (#3,689 of 21,677) with 224.8 V nominal Voc. An 8 kW residential build (8,075 W DC, 7,608 W PTC) saves ~$2,020/yr at 18.54 c/kWh with zero federal 25D credit in 2026. Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Peer Applied Materials Full Size Tandem Junction offers a 458.0 W alternative.
Where Does First Solar Inc FS-6475A-P Fall Across Listed CEC Models?
Plots First Solar Inc FS-6475A-P at 475.0 W STC across all 21,677 California Energy Commission photovoltaic modules relative to the 385.0 W median.
What Dataset Percentiles Define First Solar Inc FS-6475A-P?
Benchmarks First Solar Inc FS-6475A-P on STC wattage, thermal PTC/STC retention, and 18.85 aperture conversion efficiency against CEC peers.
What Do the Dataset Ranks Show for First Solar Inc FS-6475A-P?
Key electrical performance ranks, roof area sizing, and NEC 690.7/690.8 design boundaries for First Solar Inc FS-6475A-P by First Solar Inc.
Top 22.9% STC Output
475.0 W STC (+90.0 W vs all-CEC median) vs 445.0 W CdTe median.
18.85% Aperture Efficiency
Power density 188.5 W/m2 (1.06 percentage points below 19.91% CEC median). PTC/STC ratio: 94.2% (rank #3,689).
2 Panels Max @ -10 C (600 V)
Cold Voc reaches 246.59 V at -10 C (493.2 V string) and 252.82 V at -20 C (2 max).
17 Panels = 8,075 W STC
Occupies 42.8 m2 (461 sq ft) producing 7,608 W PTC; NEC 690.8 OCPD floor is 4.07 A (15 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 224.8 * (1 + (-0.277/100) * (-10 - 25)) = 246.59 V | OCPD = 1.56 * 2.61 = 4.07 A
Inputs from CEC Modules.csv for First Solar Inc FS-6475A-P: Voc=224.8 V, beta_Voc=-0.277%/C, Isc=2.61 A, STC=475.0 W, Area=2.52 m2.
Result: 2 panels max on 600 V (493.2 V); 17 panels for 8 kW (461 sq ft).
What Are the Published CEC Specifications for First Solar Inc FS-6475A-P?
Laboratory test ratings recorded for First Solar Inc FS-6475A-P (CdTe) in the official California Energy Commission NREL SAM equipment catalog.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 475.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 447.5 W (94.2% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 224.8 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 2.61 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 191.5 V / 2.48 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.277 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 18.85% (2.52 m2) | Array roof footprint density |
| Cell Count & Technology | 268 cells (CdTe) | Monofacial backsheet |
How Many First Solar Inc FS-6475A-P Panels Build a 6 kW, 8 kW, or 10 kW Array?
Panel counts, roof square footage (461 sq ft at 8 kW), and estimated Year-1 electric bill offset for First Solar Inc FS-6475A-P.
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 13 | 6.17 kW | 353 sq ft | $1,544 | $2,611 |
| 8 kW Class | 17 | 8.07 kW | 461 sq ft | $2,020 | $3,415 |
| 10 kW Class | 22 | 10.45 kW | 597 sq ft | $2,616 | $4,423 |
How Many First Solar Inc FS-6475A-P Modules Fit in a Cold-Weather String?
Cold-weather Voc escalation for First Solar Inc FS-6475A-P (beta_Voc -0.277%/C) across 600 V residential and 1,000 V commercial inverters.
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 252.82 V | 2 panels | 505.6 V | 3 panels |
| -10 C (14 F) | 246.59 V | 2 panels | 493.2 V | 4 panels |
| 0 C (32 F) | 240.37 V | 2 panels | 480.7 V | 4 panels |
| 25 C (77 F STC) | 224.8 V | 2 panels | 449.6 V | 4 panels |
Which Cross-Brand Solar Modules Compare Closest to First Solar Inc FS-6475A-P?
Closest cross-brand CEC competitors to First Solar Inc FS-6475A-P matched near 475.0 W STC and 224.8 V Voc, led by Applied Materials Full Size Tandem Junction.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| Applied Materials Full Size Tandem Junction Applied Materials |
458.0 W | -17.0 W | 280.0 V | 8.01% | 91.7% |
| Heliene 96M475 Heliene |
475.0 W | Tie (0 W) | 62.39 V | 18.85% | 90.5% |
| Heliene 96M460 Heliene |
460.0 W | -15.0 W | 61.79 V | 18.25% | 90.4% |
| CSI Solar Co Ltd CS3Y-480P CSI Solar Co Ltd |
480.0 W | +5.0 W | 52.8 V | 20.96% | 93.2% |
What Are the Design Limits and Best-Fit Uses for First Solar Inc FS-6475A-P?
Evaluate First Solar Inc FS-6475A-P (475.0 W STC, 224.8 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), First Solar Inc FS-6475A-P reaches 252.82 V per panel—exceeding 2 panels in series voids 600 V inverter warranties.
- Footprint constraint: 17 panels for an 8 kW build require 461 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 17 panels (461 sq ft) for an 8 kW array.
- 2026 tax credit baseline: cash residential installs of First Solar Inc FS-6475A-P carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
First Solar Inc FS-6475A-P 8 kW Residential Fit
Needs 17 modules (461 sq ft) with a 15 A string OCPD, offsetting ~$2,020/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 2 panels (-10 C) or 2 panels (-20 C), or compare Applied Materials Full Size Tandem Junction.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 447.5 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for First Solar Inc FS-6475A-P by First Solar Inc grounded in CEC test data and NEC 690.7/690.8 limits.
What fuse or breaker size does NEC 690.8 require for First Solar Inc FS-6475A-P?
Multiplying First Solar Inc FS-6475A-P's 2.61 A short-circuit current by 1.56 equals 4.07 A minimum ampacity, requiring at least a 15 A overcurrent fuse or breaker.
Can First Solar Inc FS-6475A-P pair with microinverters instead of a 600 V string inverter?
Yes—if the microinverter DC input ceiling exceeds 246.59 V cold Voc at 14 F and handles 2.61 A Isc; string inverters cap First Solar Inc FS-6475A-P at 2 panels on 600 V.
Is First Solar Inc FS-6475A-P eligible for the 30% federal 25D solar credit in 2026?
No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of First Solar Inc FS-6475A-P rely on utility bill offset (~$2,020/yr at 8 kW) rather than 25D.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)