First Solar Inc FS-6475A-P-I is a 475.0 W STC (447.5 W PTC) CdTe solar module ranking #4,892 of 21,677 CEC listings (top 22.9%; higher than 77.1% of peers). It delivers 18.85% efficiency, 224.8 V Voc at 25 C, and 246.59 V cold Voc at -10 C (2 panels max per 600 V string).

STC Wattage
475.0 W
PTC Wattage
447.5 W
Voc @ 25C
224.8 V
Efficiency
18.85%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does First Solar Inc FS-6475A-P-I Compare Against Peer CEC Listings?

CEC rank, roof space requirements, and NEC 690.7/690.8 limits for First Solar Inc FS-6475A-P-I (CdTe) residential solar systems.

Homeowners evaluating First Solar Inc FS-6475A-P-I need 13 panels for 6 kW or 17 panels (461 sq ft) for an 8 kW array—well-proportioned for residential pitched roofs needing 17 panels (461 sq ft) for an 8 kW array. Under NEC 690.7(A), beta_Voc (-0.277%/C) pushes open-circuit voltage to 246.59 V at 14 F and 252.82 V at -4 F. Monofacial backsheet sealing targets flush dark shingle rooftop mounts.

Where Does First Solar Inc FS-6475A-P-I Fall Across Listed CEC Models?

Comparison of First Solar Inc FS-6475A-P-I (475.0 W STC) against all 21,677 California Energy Commission certified photovoltaic modules.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where First Solar Inc FS-6475A-P-I (475.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCFirst Solar Inc FS: 475.0 W

What Dataset Percentiles Define First Solar Inc FS-6475A-P-I?

Relative ranking of First Solar Inc FS-6475A-P-I across nameplate watts, 94.2% PTC thermal ratio, and module aperture efficiency.

First Solar Inc FS-6475A-P-I Engineering BenchmarksPercentile comparison of First Solar Inc FS-6475A-P-I wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage475.0 WPTC/STC Retention94.2%Module Efficiency18.85%

What Do the Dataset Ranks Show for First Solar Inc FS-6475A-P-I?

Summary of First Solar Inc FS-6475A-P-I output rank, 8 kW array size (17 panels), efficiency rating, and 600 V string limit.

Rank #4,892 / 21,677

Top 22.9% STC Output

475.0 W STC (+90.0 W vs all-CEC median) vs 445.0 W CdTe median.

Eff #13,722

18.85% Aperture Efficiency

Power density 188.5 W/m2 (1.06 percentage points below 19.91% CEC median). PTC/STC ratio: 94.2% (rank #3,689).

NEC 690.7 Limit

2 Panels Max @ -10 C (600 V)

Cold Voc reaches 246.59 V at -10 C (493.2 V string) and 252.82 V at -20 C (2 max).

8 kW Reference Array

17 Panels = 8,075 W STC

Occupies 42.8 m2 (461 sq ft) producing 7,608 W PTC; NEC 690.8 OCPD floor is 4.07 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 224.8 * (1 + (-0.277/100) * (-10 - 25)) = 246.59 V | OCPD = 1.56 * 2.61 = 4.07 A

Inputs from CEC Modules.csv for First Solar Inc FS-6475A-P-I: Voc=224.8 V, beta_Voc=-0.277%/C, Isc=2.61 A, STC=475.0 W, Area=2.52 m2.

Result: 2 panels max on 600 V (493.2 V); 17 panels for 8 kW (461 sq ft).

What Are the Published CEC Specifications for First Solar Inc FS-6475A-P-I?

Complete CEC test sheet for First Solar Inc FS-6475A-P-I including Isc (2.61 A), Voc (224.8 V), and thermal temperature coefficients.

Official California Energy Commission (NREL SAM) test parameters for First Solar Inc FS-6475A-P-I.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 475.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 447.5 W (94.2% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 224.8 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 2.61 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 191.5 V / 2.48 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.277 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 18.85% (2.52 m2) Array roof footprint density
Cell Count & Technology 268 cells (CdTe) Monofacial backsheet

How Many First Solar Inc FS-6475A-P-I Panels Build a 6 kW, 8 kW, or 10 kW Array?

Residential array count and annual electric bill savings at 18.54 c/kWh US avg vs. California tariffs using First Solar Inc FS-6475A-P-I.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 13 6.17 kW 353 sq ft $1,544 $2,611
8 kW Class 17 8.07 kW 461 sq ft $2,020 $3,415
10 kW Class 22 10.45 kW 597 sq ft $2,616 $4,423

How Many First Solar Inc FS-6475A-P-I Modules Fit in a Cold-Weather String?

Verify freezing-morning voltage rise for First Solar Inc FS-6475A-P-I (224.8 V STC) before wiring 600 V or 1,000 V strings.

Computed from Voc=224.8V and beta_Voc=-0.277%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 252.82 V 2 panels 505.6 V 3 panels
-10 C (14 F) 246.59 V 2 panels 493.2 V 4 panels
0 C (32 F) 240.37 V 2 panels 480.7 V 4 panels
25 C (77 F STC) 224.8 V 2 panels 449.6 V 4 panels

Which Cross-Brand Solar Modules Compare Closest to First Solar Inc FS-6475A-P-I?

Four comparable CEC modules such as Applied Materials Full Size Tandem Junction (458.0 W) for side-by-side solar quote checks.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
Applied Materials Full Size Tandem Junction
Applied Materials
458.0 W -17.0 W 280.0 V 8.01% 91.7%
Heliene 96M475
Heliene
475.0 W Tie (0 W) 62.39 V 18.85% 90.5%
Heliene 96M460
Heliene
460.0 W -15.0 W 61.79 V 18.25% 90.4%
CSI Solar Co Ltd CS3Y-480P
CSI Solar Co Ltd
480.0 W +5.0 W 52.8 V 20.96% 93.2%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for First Solar Inc FS-6475A-P-I?

Evaluate First Solar Inc FS-6475A-P-I (475.0 W STC, 224.8 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), First Solar Inc FS-6475A-P-I reaches 252.82 V per panel—exceeding 2 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 17 panels for an 8 kW build require 461 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 17 panels (461 sq ft) for an 8 kW array.
  • 2026 tax credit baseline: cash residential installs of First Solar Inc FS-6475A-P-I carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

First Solar Inc FS-6475A-P-I 8 kW Residential Fit

Needs 17 modules (461 sq ft) with a 15 A string OCPD, offsetting ~$2,020/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 2 panels (-10 C) or 2 panels (-20 C), or compare Applied Materials Full Size Tandem Junction.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 447.5 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for First Solar Inc FS-6475A-P-I by First Solar Inc grounded in CEC test data and NEC 690.7/690.8 limits.

Why is First Solar Inc FS-6475A-P-I PTC wattage (447.5 W) lower than STC (475.0 W)?

Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 447.5 W PTC (94.2% retention) across First Solar Inc FS-6475A-P-I's 2.52 m2 aperture.

Who should skip First Solar Inc FS-6475A-P-I on a complex residential roof?

Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 17 First Solar Inc FS-6475A-P-I panels (461 sq ft) leave unusable roof gaps vs. Applied Materials Full Size Tandem Junction.

What is the 1,000 V commercial string limit for First Solar Inc FS-6475A-P-I?

On 1,000 V commercial inverters at -10 C (246.59 V cold Voc), First Solar Inc FS-6475A-P-I fits up to 4 panels per series string. Review current municipal Authority Having Jurisdiction (AHJ) code amendments affecting First Solar Inc FS-6475A-P-I.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.