First Solar Inc FS-6470A-P-B is a 470.0 W STC (435.4 W PTC) CdTe solar module ranking #4,967 of 21,677 CEC listings (top 23.4%; higher than 76.6% of peers). It delivers 18.65% efficiency, 224.3 V Voc at 25 C, and 245.57 V cold Voc at -10 C (2 panels max per 600 V string).
- STC Wattage
- 470.0 W
- PTC Wattage
- 435.4 W
- Voc @ 25C
- 224.3 V
- Efficiency
- 18.65%
How Does First Solar Inc FS-6470A-P-B Compare Against Peer CEC Listings?
CEC rank, roof space requirements, and NEC 690.7/690.8 limits for First Solar Inc FS-6470A-P-B (CdTe) residential solar systems.
First Solar Inc FS-6470A-P-B delivers 186.5 W/m2 (1.26 percentage points below 19.91% CEC median) and strong 92.6% PTC-to-STC heat retention (#11,981 of 21,677), placing it as a modern high-density residential and light-commercial module well-proportioned for residential pitched roofs needing 18 panels (488 sq ft) for an 8 kW array. At -4 F (-20 C), string voltage climbs to 251.65 V per unit, capping 600 V circuits at 2 panels. Compare specs directly with Applied Materials Full Size Tandem Junction (458.0 W).
Where Does First Solar Inc FS-6470A-P-B Fall Across Listed CEC Models?
Comparison of First Solar Inc FS-6470A-P-B (470.0 W STC) against all 21,677 California Energy Commission certified photovoltaic modules.
What Dataset Percentiles Define First Solar Inc FS-6470A-P-B?
Relative ranking of First Solar Inc FS-6470A-P-B across nameplate watts, 92.6% PTC thermal ratio, and module aperture efficiency.
What Do the Dataset Ranks Show for First Solar Inc FS-6470A-P-B?
Summary of First Solar Inc FS-6470A-P-B output rank, 8 kW array size (18 panels), efficiency rating, and 600 V string limit.
Top 23.4% STC Output
470.0 W STC (+85.0 W vs all-CEC median) vs 445.0 W CdTe median.
18.65% Aperture Efficiency
Power density 186.5 W/m2 (1.26 percentage points below 19.91% CEC median). PTC/STC ratio: 92.6% (rank #11,981).
2 Panels Max @ -10 C (600 V)
Cold Voc reaches 245.57 V at -10 C (491.1 V string) and 251.65 V at -20 C (2 max).
18 Panels = 8,460 W STC
Occupies 45.4 m2 (488 sq ft) producing 7,837 W PTC; NEC 690.8 OCPD floor is 4.07 A (15 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 224.3 * (1 + (-0.271/100) * (-10 - 25)) = 245.57 V | OCPD = 1.56 * 2.61 = 4.07 A
Inputs from CEC Modules.csv for First Solar Inc FS-6470A-P-B: Voc=224.3 V, beta_Voc=-0.271%/C, Isc=2.61 A, STC=470.0 W, Area=2.52 m2.
Result: 2 panels max on 600 V (491.1 V); 18 panels for 8 kW (488 sq ft).
What Are the Published CEC Specifications for First Solar Inc FS-6470A-P-B?
Complete CEC test sheet for First Solar Inc FS-6470A-P-B including Isc (2.61 A), Voc (224.3 V), and thermal temperature coefficients.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 470.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 435.4 W (92.6% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 224.3 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 2.61 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 191.1 V / 2.46 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.271 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 18.65% (2.52 m2) | Array roof footprint density |
| Cell Count & Technology | 268 cells (CdTe) | Monofacial backsheet |
How Many First Solar Inc FS-6470A-P-B Panels Build a 6 kW, 8 kW, or 10 kW Array?
Residential array count and annual electric bill savings at 18.54 c/kWh US avg vs. California tariffs using First Solar Inc FS-6470A-P-B.
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 13 | 6.11 kW | 353 sq ft | $1,529 | $2,586 |
| 8 kW Class | 18 | 8.46 kW | 488 sq ft | $2,117 | $3,580 |
| 10 kW Class | 22 | 10.34 kW | 597 sq ft | $2,588 | $4,376 |
How Many First Solar Inc FS-6470A-P-B Modules Fit in a Cold-Weather String?
Verify freezing-morning voltage rise for First Solar Inc FS-6470A-P-B (224.3 V STC) before wiring 600 V or 1,000 V strings.
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 251.65 V | 2 panels | 503.3 V | 3 panels |
| -10 C (14 F) | 245.57 V | 2 panels | 491.1 V | 4 panels |
| 0 C (32 F) | 239.5 V | 2 panels | 479.0 V | 4 panels |
| 25 C (77 F STC) | 224.3 V | 2 panels | 448.6 V | 4 panels |
Which Cross-Brand Solar Modules Compare Closest to First Solar Inc FS-6470A-P-B?
Four comparable CEC modules such as Applied Materials Full Size Tandem Junction (458.0 W) for side-by-side solar quote checks.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| Applied Materials Full Size Tandem Junction Applied Materials |
458.0 W | -12.0 W | 280.0 V | 8.01% | 91.7% |
| Heliene 96M475 Heliene |
475.0 W | +5.0 W | 62.39 V | 18.85% | 90.5% |
| Heliene 96M460 Heliene |
460.0 W | -10.0 W | 61.79 V | 18.25% | 90.4% |
| CSI Solar Co Ltd CS3Y-470MS CSI Solar Co Ltd |
470.0 W | Tie (0 W) | 52.5 V | 20.52% | 93.5% |
What Are the Design Limits and Best-Fit Uses for First Solar Inc FS-6470A-P-B?
Evaluate First Solar Inc FS-6470A-P-B (470.0 W STC, 224.3 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), First Solar Inc FS-6470A-P-B reaches 251.65 V per panel—exceeding 2 panels in series voids 600 V inverter warranties.
- Footprint constraint: 18 panels for an 8 kW build require 488 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 18 panels (488 sq ft) for an 8 kW array.
- 2026 tax credit baseline: cash residential installs of First Solar Inc FS-6470A-P-B carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
First Solar Inc FS-6470A-P-B 8 kW Residential Fit
Needs 18 modules (488 sq ft) with a 15 A string OCPD, offsetting ~$2,117/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 2 panels (-10 C) or 2 panels (-20 C), or compare Applied Materials Full Size Tandem Junction.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 435.4 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for First Solar Inc FS-6470A-P-B by First Solar Inc grounded in CEC test data and NEC 690.7/690.8 limits.
How many First Solar Inc FS-6470A-P-B panels fit on a 600 V winter solar string?
At -10 C (14 F), First Solar Inc FS-6470A-P-B cold Voc rises from 224.3 V to 245.57 V (beta_Voc -0.271%/C), capping a 600 V string at 2 panels (491.1 V).
How much roof area does an 8 kW array of First Solar Inc FS-6470A-P-B need?
An 8 kW DC system uses 18 First Solar Inc FS-6470A-P-B modules (8,460 W STC / 7,837 W PTC), covering roughly 488 sq ft and saving ~$2,117/yr at 18.54 c/kWh.
How does First Solar Inc FS-6470A-P-B compare against Applied Materials Full Size Tandem Junction?
First Solar Inc FS-6470A-P-B outputs 470.0 W STC (224.3 V Voc, rank #4,967 of 21,677), while Applied Materials Full Size Tandem Junction delivers 458.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)