Skip to main content
WireAndSun
Calculators
CEC PV Module

First Solar Inc FS-6470-P-B — CEC Solar Module Specifications

Manufacturer: First Solar Inc Registry: CEC Verified Engineering Specification

First Solar Inc FS-6470-P-B is a 470.0 W STC (435.4 W PTC) CdTe solar module ranking #4,967 of 21,677 CEC listings (top 23.4%; higher than 76.6% of peers). It delivers 18.65% efficiency, 224.3 V Voc at 25 C, and 245.57 V cold Voc at -10 C (2 panels max per 600 V string).

STC Wattage
470.0 W
PTC Wattage
435.4 W
Voc @ 25C
224.3 V
Efficiency
18.65%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does First Solar Inc FS-6470-P-B Compare Against Peer CEC Listings?

How First Solar Inc First Solar Inc FS-6470-P-B handles rooftop heat (435.4 W PTC), 8 kW sizing, and cold winter string voltage.

For NEC string engineering, First Solar Inc FS-6470-P-B exhibits 2.61 A short-circuit current, requiring a 4.07 A (156%) conductor rating and 15 A OCPD under NEC 690.8. Ranked #4,967 of 21,677 (25.0 W above the 445.0 W CdTe median), this modern high-density residential and light-commercial module covers 45.4 m2 for an 8 kW system (22 panels for 10 kW). Higher 224.3 V open-circuit voltage caps 600 V residential strings at 2 panels at 14 F (-10 C).

Where Does First Solar Inc FS-6470-P-B Fall Across Listed CEC Models?

Where First Solar Inc FS-6470-P-B (470.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where First Solar Inc FS-6470-P-B (470.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCFirst Solar Inc FS: 470.0 W

What Dataset Percentiles Define First Solar Inc FS-6470-P-B?

Percentile placement of First Solar Inc FS-6470-P-B across power density (186.5 W/m2), thermal retention, and nameplate STC wattage.

First Solar Inc FS-6470-P-B Engineering BenchmarksPercentile comparison of First Solar Inc FS-6470-P-B wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage470.0 WPTC/STC Retention92.6%Module Efficiency18.65%

What Do the Dataset Ranks Show for First Solar Inc FS-6470-P-B?

Four critical engineering numbers homeowners and solar installers check first when reviewing First Solar Inc FS-6470-P-B specifications. Always verify current state NEC adoption cycles, local utility interconnection tariffs, and panel busbar ratings before pulling project permits.

Rank #4,967 / 21,677

Top 23.4% STC Output

470.0 W STC (+85.0 W vs all-CEC median) vs 445.0 W CdTe median.

Eff #14,111

18.65% Aperture Efficiency

Power density 186.5 W/m2 (1.26 percentage points below 19.91% CEC median). PTC/STC ratio: 92.6% (rank #11,981).

NEC 690.7 Limit

2 Panels Max @ -10 C (600 V)

Cold Voc reaches 245.57 V at -10 C (491.1 V string) and 251.65 V at -20 C (2 max).

8 kW Reference Array

18 Panels = 8,460 W STC

Occupies 45.4 m2 (488 sq ft) producing 7,837 W PTC; NEC 690.8 OCPD floor is 4.07 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 224.3 * (1 + (-0.271/100) * (-10 - 25)) = 245.57 V | OCPD = 1.56 * 2.61 = 4.07 A

Inputs from CEC Modules.csv for First Solar Inc FS-6470-P-B: Voc=224.3 V, beta_Voc=-0.271%/C, Isc=2.61 A, STC=470.0 W, Area=2.52 m2.

Result: 2 panels max on 600 V (491.1 V); 18 panels for 8 kW (488 sq ft).

What Are the Published CEC Specifications for First Solar Inc FS-6470-P-B?

Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for First Solar Inc FS-6470-P-B.

Official California Energy Commission (NREL SAM) test parameters for First Solar Inc FS-6470-P-B.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 470.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 435.4 W (92.6% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 224.3 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 2.61 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 191.1 V / 2.46 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.271 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 18.65% (2.52 m2) Array roof footprint density
Cell Count & Technology 268 cells (CdTe) Monofacial backsheet

How Many First Solar Inc FS-6470-P-B Panels Build a 6 kW, 8 kW, or 10 kW Array?

Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using First Solar Inc FS-6470-P-B (470.0 W).

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 13 6.11 kW 353 sq ft $1,529 $2,586
8 kW Class 18 8.46 kW 488 sq ft $2,117 $3,580
10 kW Class 22 10.34 kW 597 sq ft $2,588 $4,376

How Many First Solar Inc FS-6470-P-B Modules Fit in a Cold-Weather String?

Maximum series module counts for First Solar Inc FS-6470-P-B from 25 C down to -20 C (-4 F) under NEC 690.7.

Computed from Voc=224.3V and beta_Voc=-0.271%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 251.65 V 2 panels 503.3 V 3 panels
-10 C (14 F) 245.57 V 2 panels 491.1 V 4 panels
0 C (32 F) 239.5 V 2 panels 479.0 V 4 panels
25 C (77 F STC) 224.3 V 2 panels 448.6 V 4 panels

Which Cross-Brand Solar Modules Compare Closest to First Solar Inc FS-6470-P-B?

Alternative CEC solar modules from competing brands near First Solar Inc FS-6470-P-B (470.0 W), including Applied Materials Full Size Tandem Junction.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
Applied Materials Full Size Tandem Junction
Applied Materials
458.0 W -12.0 W 280.0 V 8.01% 91.7%
Heliene 96M475
Heliene
475.0 W +5.0 W 62.39 V 18.85% 90.5%
Heliene 96M460
Heliene
460.0 W -10.0 W 61.79 V 18.25% 90.4%
CSI Solar Co Ltd CS3Y-470MS
CSI Solar Co Ltd
470.0 W Tie (0 W) 52.5 V 20.52% 93.5%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for First Solar Inc FS-6470-P-B?

Evaluate First Solar Inc FS-6470-P-B (470.0 W STC, 224.3 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), First Solar Inc FS-6470-P-B reaches 251.65 V per panel—exceeding 2 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 18 panels for an 8 kW build require 488 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 18 panels (488 sq ft) for an 8 kW array.
  • 2026 tax credit baseline: cash residential installs of First Solar Inc FS-6470-P-B carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

First Solar Inc FS-6470-P-B 8 kW Residential Fit

Needs 18 modules (488 sq ft) with a 15 A string OCPD, offsetting ~$2,117/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 2 panels (-10 C) or 2 panels (-20 C), or compare Applied Materials Full Size Tandem Junction.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 435.4 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for First Solar Inc FS-6470-P-B by First Solar Inc grounded in CEC test data and NEC 690.7/690.8 limits.

Why is First Solar Inc FS-6470-P-B PTC wattage (435.4 W) lower than STC (470.0 W)?

Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 435.4 W PTC (92.6% retention) across First Solar Inc FS-6470-P-B's 2.52 m2 aperture.

Who should skip First Solar Inc FS-6470-P-B on a complex residential roof?

Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 18 First Solar Inc FS-6470-P-B panels (488 sq ft) leave unusable roof gaps vs. Applied Materials Full Size Tandem Junction.

What is the 1,000 V commercial string limit for First Solar Inc FS-6470-P-B?

On 1,000 V commercial inverters at -10 C (245.57 V cold Voc), First Solar Inc FS-6470-P-B fits up to 4 panels per series string. Review current municipal Authority Having Jurisdiction (AHJ) code amendments affecting First Solar Inc FS-6470-P-B.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.