Manufacturer: First Solar Inc Registry: CEC Verified Engineering Specification

First Solar Inc FS-6460A-P-x is a 460.0 W STC (423.8 W PTC) CdTe solar module ranking #5,199 of 21,677 CEC listings (top 25.0%; higher than 75.0% of peers). It delivers 18.25% efficiency, 222.9 V Voc at 25 C, and 244.9 V cold Voc at -10 C (2 panels max per 600 V string).

STC Wattage
460.0 W
PTC Wattage
423.8 W
Voc @ 25C
222.9 V
Efficiency
18.25%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does First Solar Inc FS-6460A-P-x Compare Against Peer CEC Listings?

Solar engineering breakdown for First Solar Inc FS-6460A-P-x: PTC thermal retention, roof footprint, and cold Voc string bounds.

Measured at 460.0 W STC and 423.8 W PTC, First Solar Inc FS-6460A-P-x sits +75.0 W vs all-CEC median (top 25.0%; higher than 75.0% of peers) among 21,677 listed modules. Power density reaches 182.5 W/m2 (1.66 percentage points below 19.91% CEC median). Higher 222.9 V open-circuit voltage caps 600 V residential strings at 2 panels at 14 F (-10 C), whereas 1,000 V commercial inverters handle up to 4 panels in series. Alternative peer Applied Materials Full Size Tandem Junction rates 458.0 W.

Where Does First Solar Inc FS-6460A-P-x Fall Across Listed CEC Models?

Distribution marker showing First Solar Inc FS-6460A-P-x (460.0 W) relative to the 385.0 W all-CEC solar panel median.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where First Solar Inc FS-6460A-P-x (460.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCFirst Solar Inc FS: 460.0 W

What Dataset Percentiles Define First Solar Inc FS-6460A-P-x?

Dataset percentiles tracking First Solar Inc FS-6460A-P-x power output, thermal retention ratio, and aperture efficiency against 21,677 models.

First Solar Inc FS-6460A-P-x Engineering BenchmarksPercentile comparison of First Solar Inc FS-6460A-P-x wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage460.0 WPTC/STC Retention92.1%Module Efficiency18.25%

What Do the Dataset Ranks Show for First Solar Inc FS-6460A-P-x?

Benchmark highlights for First Solar Inc FS-6460A-P-x covering STC output, efficiency, 8 kW footprint, and OCPD breaker size.

Rank #5,199 / 21,677

Top 25.0% STC Output

460.0 W STC (+75.0 W vs all-CEC median) vs 445.0 W CdTe median.

Eff #14,750

18.25% Aperture Efficiency

Power density 182.5 W/m2 (1.66 percentage points below 19.91% CEC median). PTC/STC ratio: 92.1% (rank #13,846).

NEC 690.7 Limit

2 Panels Max @ -10 C (600 V)

Cold Voc reaches 244.9 V at -10 C (489.8 V string) and 251.19 V at -20 C (2 max).

8 kW Reference Array

18 Panels = 8,280 W STC

Occupies 45.4 m2 (488 sq ft) producing 7,628 W PTC; NEC 690.8 OCPD floor is 4.04 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 222.9 * (1 + (-0.282/100) * (-10 - 25)) = 244.9 V | OCPD = 1.56 * 2.59 = 4.04 A

Inputs from CEC Modules.csv for First Solar Inc FS-6460A-P-x: Voc=222.9 V, beta_Voc=-0.282%/C, Isc=2.59 A, STC=460.0 W, Area=2.52 m2.

Result: 2 panels max on 600 V (489.8 V); 18 panels for 8 kW (488 sq ft).

What Are the Published CEC Specifications for First Solar Inc FS-6460A-P-x?

Official CEC datasheet figures for First Solar Inc FS-6460A-P-x (CdTe) used in utility interconnection and permit reviews. All figures trace directly to published federal energy filings, state electrical boards, CEC datasheets, and NFPA 70 NEC tables.

Official California Energy Commission (NREL SAM) test parameters for First Solar Inc FS-6460A-P-x.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 460.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 423.8 W (92.1% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 222.9 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 2.59 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 188.8 V / 2.44 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.282 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 18.25% (2.52 m2) Array roof footprint density
Cell Count & Technology 264 cells (CdTe) Monofacial backsheet

How Many First Solar Inc FS-6460A-P-x Panels Build a 6 kW, 8 kW, or 10 kW Array?

How many First Solar Inc FS-6460A-P-x modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 14 6.44 kW 380 sq ft $1,612 $2,726
8 kW Class 18 8.28 kW 488 sq ft $2,072 $3,504
10 kW Class 22 10.12 kW 597 sq ft $2,533 $4,283

How Many First Solar Inc FS-6460A-P-x Modules Fit in a Cold-Weather String?

NEC 690.7(A) winter string table preventing overvoltage trips on First Solar Inc FS-6460A-P-x (244.9 V at 14 F).

Computed from Voc=222.9V and beta_Voc=-0.282%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 251.19 V 2 panels 502.4 V 3 panels
-10 C (14 F) 244.9 V 2 panels 489.8 V 4 panels
0 C (32 F) 238.61 V 2 panels 477.2 V 4 panels
25 C (77 F STC) 222.9 V 2 panels 445.8 V 4 panels

Which Cross-Brand Solar Modules Compare Closest to First Solar Inc FS-6460A-P-x?

Competing CEC solar panels closest to First Solar Inc FS-6460A-P-x in nameplate wattage and Voc, starting with Applied Materials Full Size Tandem Junction.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
Applied Materials Full Size Tandem Junction
Applied Materials
458.0 W -2.0 W 280.0 V 8.01% 91.7%
Heliene 96M460
Heliene
460.0 W Tie (0 W) 61.79 V 18.25% 90.4%
Heliene 96M475
Heliene
475.0 W +15.0 W 62.39 V 18.85% 90.5%
CSI Solar Co Ltd CS3Y-460P
CSI Solar Co Ltd
460.0 W Tie (0 W) 52.0 V 20.09% 93.1%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for First Solar Inc FS-6460A-P-x?

Evaluate First Solar Inc FS-6460A-P-x (460.0 W STC, 222.9 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), First Solar Inc FS-6460A-P-x reaches 251.19 V per panel—exceeding 2 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 18 panels for an 8 kW build require 488 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 18 panels (488 sq ft) for an 8 kW array.
  • 2026 tax credit baseline: cash residential installs of First Solar Inc FS-6460A-P-x carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

First Solar Inc FS-6460A-P-x 8 kW Residential Fit

Needs 18 modules (488 sq ft) with a 15 A string OCPD, offsetting ~$2,072/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 2 panels (-10 C) or 2 panels (-20 C), or compare Applied Materials Full Size Tandem Junction.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 423.8 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for First Solar Inc FS-6460A-P-x by First Solar Inc grounded in CEC test data and NEC 690.7/690.8 limits.

How many First Solar Inc FS-6460A-P-x panels fit on a 600 V winter solar string?

At -10 C (14 F), First Solar Inc FS-6460A-P-x cold Voc rises from 222.9 V to 244.9 V (beta_Voc -0.282%/C), capping a 600 V string at 2 panels (489.8 V).

How much roof area does an 8 kW array of First Solar Inc FS-6460A-P-x need?

An 8 kW DC system uses 18 First Solar Inc FS-6460A-P-x modules (8,280 W STC / 7,628 W PTC), covering roughly 488 sq ft and saving ~$2,072/yr at 18.54 c/kWh.

How does First Solar Inc FS-6460A-P-x compare against Applied Materials Full Size Tandem Junction?

First Solar Inc FS-6460A-P-x outputs 460.0 W STC (222.9 V Voc, rank #5,199 of 21,677), while Applied Materials Full Size Tandem Junction delivers 458.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.