First Solar Inc FS-6460-P is a 460.0 W STC (431.5 W PTC) CdTe solar module ranking #5,199 of 21,677 CEC listings (top 25.0%; higher than 75.0% of peers). It delivers 18.25% efficiency, 222.9 V Voc at 25 C, and 244.04 V cold Voc at -10 C (2 panels max per 600 V string).
- STC Wattage
- 460.0 W
- PTC Wattage
- 431.5 W
- Voc @ 25C
- 222.9 V
- Efficiency
- 18.25%
How Does First Solar Inc FS-6460-P Compare Against Peer CEC Listings?
How First Solar Inc First Solar Inc FS-6460-P handles rooftop heat (431.5 W PTC), 8 kW sizing, and cold winter string voltage.
For NEC string engineering, First Solar Inc FS-6460-P exhibits 2.59 A short-circuit current, requiring a 4.04 A (156%) conductor rating and 15 A OCPD under NEC 690.8. Ranked #5,199 of 21,677 (15.0 W above the 445.0 W CdTe median), this modern high-density residential and light-commercial module covers 45.4 m2 for an 8 kW system (22 panels for 10 kW). Higher 222.9 V open-circuit voltage caps 600 V residential strings at 2 panels at 14 F (-10 C).
Where Does First Solar Inc FS-6460-P Fall Across Listed CEC Models?
Where First Solar Inc FS-6460-P (460.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.
What Dataset Percentiles Define First Solar Inc FS-6460-P?
Percentile placement of First Solar Inc FS-6460-P across power density (182.5 W/m2), thermal retention, and nameplate STC wattage.
What Do the Dataset Ranks Show for First Solar Inc FS-6460-P?
Four critical engineering numbers homeowners and solar installers check first when reviewing First Solar Inc FS-6460-P specifications. All figures trace directly to published federal energy filings, state electrical boards, CEC datasheets, and NFPA 70 NEC tables.
Top 25.0% STC Output
460.0 W STC (+75.0 W vs all-CEC median) vs 445.0 W CdTe median.
18.25% Aperture Efficiency
Power density 182.5 W/m2 (1.66 percentage points below 19.91% CEC median). PTC/STC ratio: 93.8% (rank #5,632).
2 Panels Max @ -10 C (600 V)
Cold Voc reaches 244.04 V at -10 C (488.1 V string) and 250.08 V at -20 C (2 max).
18 Panels = 8,280 W STC
Occupies 45.4 m2 (488 sq ft) producing 7,767 W PTC; NEC 690.8 OCPD floor is 4.04 A (15 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 222.9 * (1 + (-0.271/100) * (-10 - 25)) = 244.04 V | OCPD = 1.56 * 2.59 = 4.04 A
Inputs from CEC Modules.csv for First Solar Inc FS-6460-P: Voc=222.9 V, beta_Voc=-0.271%/C, Isc=2.59 A, STC=460.0 W, Area=2.52 m2.
Result: 2 panels max on 600 V (488.1 V); 18 panels for 8 kW (488 sq ft).
What Are the Published CEC Specifications for First Solar Inc FS-6460-P?
Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for First Solar Inc FS-6460-P.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 460.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 431.5 W (93.8% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 222.9 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 2.59 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 188.8 V / 2.44 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.271 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 18.25% (2.52 m2) | Array roof footprint density |
| Cell Count & Technology | 264 cells (CdTe) | Monofacial backsheet |
How Many First Solar Inc FS-6460-P Panels Build a 6 kW, 8 kW, or 10 kW Array?
Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using First Solar Inc FS-6460-P (460.0 W).
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 14 | 6.44 kW | 380 sq ft | $1,612 | $2,726 |
| 8 kW Class | 18 | 8.28 kW | 488 sq ft | $2,072 | $3,504 |
| 10 kW Class | 22 | 10.12 kW | 597 sq ft | $2,533 | $4,283 |
How Many First Solar Inc FS-6460-P Modules Fit in a Cold-Weather String?
Maximum series module counts for First Solar Inc FS-6460-P from 25 C down to -20 C (-4 F) under NEC 690.7.
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 250.08 V | 2 panels | 500.2 V | 3 panels |
| -10 C (14 F) | 244.04 V | 2 panels | 488.1 V | 4 panels |
| 0 C (32 F) | 238.0 V | 2 panels | 476.0 V | 4 panels |
| 25 C (77 F STC) | 222.9 V | 2 panels | 445.8 V | 4 panels |
Which Cross-Brand Solar Modules Compare Closest to First Solar Inc FS-6460-P?
Alternative CEC solar modules from competing brands near First Solar Inc FS-6460-P (460.0 W), including Applied Materials Full Size Tandem Junction.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| Applied Materials Full Size Tandem Junction Applied Materials |
458.0 W | -2.0 W | 280.0 V | 8.01% | 91.7% |
| Heliene 96M460 Heliene |
460.0 W | Tie (0 W) | 61.79 V | 18.25% | 90.4% |
| Heliene 96M475 Heliene |
475.0 W | +15.0 W | 62.39 V | 18.85% | 90.5% |
| CSI Solar Co Ltd CS3Y-460P CSI Solar Co Ltd |
460.0 W | Tie (0 W) | 52.0 V | 20.09% | 93.1% |
What Are the Design Limits and Best-Fit Uses for First Solar Inc FS-6460-P?
Evaluate First Solar Inc FS-6460-P (460.0 W STC, 222.9 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), First Solar Inc FS-6460-P reaches 250.08 V per panel—exceeding 2 panels in series voids 600 V inverter warranties.
- Footprint constraint: 18 panels for an 8 kW build require 488 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 18 panels (488 sq ft) for an 8 kW array.
- 2026 tax credit baseline: cash residential installs of First Solar Inc FS-6460-P carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
First Solar Inc FS-6460-P 8 kW Residential Fit
Needs 18 modules (488 sq ft) with a 15 A string OCPD, offsetting ~$2,072/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 2 panels (-10 C) or 2 panels (-20 C), or compare Applied Materials Full Size Tandem Junction.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 431.5 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for First Solar Inc FS-6460-P by First Solar Inc grounded in CEC test data and NEC 690.7/690.8 limits.
Why is First Solar Inc FS-6460-P PTC wattage (431.5 W) lower than STC (460.0 W)?
Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 431.5 W PTC (93.8% retention) across First Solar Inc FS-6460-P's 2.52 m2 aperture.
Who should skip First Solar Inc FS-6460-P on a complex residential roof?
Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 18 First Solar Inc FS-6460-P panels (488 sq ft) leave unusable roof gaps vs. Applied Materials Full Size Tandem Junction.
What is the 1,000 V commercial string limit for First Solar Inc FS-6460-P?
On 1,000 V commercial inverters at -10 C (244.04 V cold Voc), First Solar Inc FS-6460-P fits up to 4 panels per series string. Review current municipal Authority Having Jurisdiction (AHJ) code amendments affecting First Solar Inc FS-6460-P.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)